A new method for optimal FTU placement in distribution network under consideration of power service reliability

被引:8
|
作者
Xu, JunJun [1 ]
Wu, ZaiJun [1 ]
Yu, XingHuo [2 ]
Hu, QinRan [3 ]
Zhu, ChengZhi [4 ]
Dou, XiaoBo [1 ]
Gu, Wei [1 ]
Wu, Zhi [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
[2] RMIT Univ, Sch Engn, Melbourne, Vic 3001, Australia
[3] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[4] Zhejiang Elect Power Co, Hangzhou 310014, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
intermittent renewable sources; FTU placement; state estimation; power service reliability; ACTIVE DISTRIBUTION GRIDS; DISTRIBUTION-SYSTEMS; MEASUREMENT DEVICES; STATE ESTIMATION; PMU PLACEMENT; ALGORITHM;
D O I
10.1007/s11431-017-9152-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Modern distribution network with high penetration of intermittent renewable sources and the so-called prosumers requires more reliable distribution automation (DA) system for safe operation and control. The design of optimal feeder terminal units (FTU) placement is critical and economical for the effective DA application. Previously proposed solutions of optimal FTU placement aiming to ensure the accuracy of state estimation (SE), typically include the following two main shortcomings: 1) only to obtain the optimal FTU placement in quantity, and the analysis of FTU location is not considered yet; 2) few consider the uncertainty of intermittent power injections in the analysis of state estimation. In this paper, a modified methodology of FTU placement is proposed not only aiming to ensure the accuracy of state estimation with the minimum number of meters, but also finding those specific FTU locations to guarantee the power service reliability. Moreover, the uncertainty models of those intermittent power injections are also considered by using probability density function (PDF). The resultant optimization problem is addressed by using the covariance matrix adaptation evolution strategy (CMA-ES). Case studies demonstrate the feasibility and effectiveness of the proposed methodology.
引用
收藏
页码:1885 / 1896
页数:12
相关论文
共 50 条
  • [31] Optimal unified power quality conditioner placement and sizing in distribution systems considering network reconfiguration
    Gholami, Khalil
    Karimi, Shahram
    Dehnavi, Ehsan
    INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 2019, 32 (01)
  • [32] Robust Framework for PMU Placement and Voltage Estimation of Power Distribution Network
    Khanam, Nida
    Rihan, Mohd.
    Hameed, Salman
    IEEE ACCESS, 2025, 13 : 55841 - 55857
  • [33] Optimal micro-PMU placement and virtualization for distribution network changing topologies
    Ibarra, L.
    Aviles, J.
    Guillen, D.
    Mayo-Maldonado, J. C.
    Valdez-Resendiz, J. E.
    Ponce, P.
    SUSTAINABLE ENERGY GRIDS & NETWORKS, 2021, 27
  • [34] Operation of distribution network with optimal placement and sizing of dispatchable DGs and shunt capacitors
    Das, Sangeeta
    Das, Debapriya
    Patra, Amit
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2019, 113
  • [35] Optimal Placement of Superconducting Magnetic Energy Storages in a Distribution Network with Embedded Wind Power Generation
    Sesay, Steven Foday
    Wekesa, Cyrus Wabuge
    Ngoo, Livingstone M. H.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2024, 14 (02) : 13416 - 13424
  • [36] Optimal Monitor Placement for Voltage Unbalance Based on Distribution Network State Estimation
    Liu, Zhixuan
    Liao, Huilian
    Milanovic, Jovica V.
    Guo, Tingyan
    Tang, Xiaoqing
    2017 IEEE MANCHESTER POWERTECH, 2017,
  • [37] A multiobjective approach for optimal placement and sizing of distributed generators and capacitors in distribution network
    Biswas, Partha P.
    Mallipeddi, R.
    Suganthan, P. N.
    Amaratunga, Gehan A. J.
    APPLIED SOFT COMPUTING, 2017, 60 : 268 - 280
  • [38] Optimal Capacitor Placement in Distribution Network for Loss Reduction and Voltage Profile Improvement
    Saric, Mirza
    Hivziefendic, Jasna
    2019 18TH INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA (INFOTEH), 2019,
  • [39] Remodelling of an Electric Distribution Network Through Optimal Placement of Auto-Reclosers to Enhance System Reliability and Efficiency
    Ghosh, Bratati
    Chakraborty, Ajoy Kumar
    Bhowmik, Arup Ratan
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (03) : 3619 - 3631
  • [40] Optimal soft open point placement and open switch position selection simultaneously for power loss reduction on the electric distribution network
    Nguyen, Thuan Thanh
    Nguyen, Thang Trung
    Nguyen, Hoai Phong
    EXPERT SYSTEMS WITH APPLICATIONS, 2024, 238