Stress and Strain Patterns of 1-Piece and 2-Piece Implant Systems in Bone: A 3-Dimensional Finite Element Analysis

被引:15
|
作者
Ormianer, Zeev [1 ]
Ben Amar, Arial [1 ]
Duda, Mariusz [2 ]
Marku-Cohen, Sharon [1 ]
Lewinstein, Israel [1 ]
机构
[1] Tel Aviv Univ, Dept Oral Rehabil, Maurice & Gabriela Goldschleger Sch Dent Med, IL-69978 Tel Aviv, Israel
[2] Silesia Med Oral Med Clin, Katowice, Poland
关键词
1-piece; 2-piece; dental implant; finite element analysis; bone; DENTAL IMPLANTS; BITE FORCE; IMMEDIATE; SURVIVAL; TISSUE;
D O I
10.1097/ID.0b013e31823fce22
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of Problem: The transition from implant to abutment is solid in 1-piece (1P) and broken in 2-piece (2P) implant designs. This difference may affect occlusal load distribution and marginal bone response. Purpose: To determine whether 1P and 2P implants with equivalent geometries exhibited stresses and strains differently under applied loading conditions. Materials and Methods: Design software simulated 1P and 2P implants restored with metal copings and embedded in 3 cylindrical bone block models that varied in dimensions, density, and percentage of bone-to-implant contact. Three-dimensional, finite element analysis simulated occlusal loading. Experiments evaluated stresses and strains relative to implant design and (1) periimplant bone thickness, (2) cortical bone thickness, (3) magnitude and direction of occlusal loading, and (4) % bone-to-implant contact. Results: Implants with equivalent dimensions exhibited comparable stresses and strains in all experimental conditions. Implant diameter and periimplant bone thickness influenced stress levels. Only small-diameter (3.0 mm) 1P implants in low-density bone exhibited stress levels that might adversely affect marginal bone stability. Conclusions: Implant diameter and periimplant bone thickness influenced load distribution in bone, but the type of implant-abutment transition had no significant effect. Small-diameter 1P implants should be limited to dense bone to minimize stress concentrations. (Implant Dent 2012;21:39-45)
引用
收藏
页码:39 / 45
页数:7
相关论文
共 50 条
  • [21] Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis
    Alvarez-Arenal, Angel
    Gonzalez-Gonzalez, Ignacio
    deLlanos-Lanchares, Hector
    Brizuela-Velasco, Aritza
    Martin-Fernandez, Elena
    Ellacuria-Echebarria, Joseba
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (06) : 419 - 428
  • [22] 3-DIMENSIONAL FINITE-ELEMENT PROGRAMS FOR STRESS ANALYSIS
    ALUJEVIC, A
    ATOMKERNENERGIE, 1977, 29 (03): : 189 - 191
  • [23] Stress Distribution on Bone and Implant by Three-dimensional Finite Element Analysis
    Cheng, Hsin-Chung
    Huang, Chiung-Fang
    Lin, Yi
    Shen, Yung-Kang
    JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2014, 35 (05): : 389 - 395
  • [24] Investigation of Influence of Different Implant Size and Placement on Stress Distribution With 3-Dimensional Finite Element Analysis
    Balkaya, Mehmet Cudi
    IMPLANT DENTISTRY, 2014, 23 (06) : 716 - 722
  • [25] STRESS-ANALYSIS OF INTERMOBILE ELEMENT BY 3-DIMENSIONAL FINITE-ELEMENT
    HATA, Y
    WATANABE, F
    FUKUDA, H
    HAKAMATSUKA, Y
    NISIYAMA, K
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 117 - 117
  • [26] Three-dimensional finite element stress and strain analysis of a transfemoral osseointegration implant
    Xu, Wei
    Xu, Dong Hao
    Crocombe, A. D.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H6) : 661 - 670
  • [27] Evaluation of Temperature and Stress Distribution on 2 Different Post Systems Using 3-Dimensional Finite Element Analysis
    Deger, Yalcin
    Adiguzel, Ozkan
    Ozer, Senem Yigit
    Kaya, Sadullah
    Polat, Zelal Seyfioglu
    Bozyel, Bejna
    MEDICAL SCIENCE MONITOR, 2015, 21 : 3716 - 3721
  • [28] Changes in stress distribution of orthodontic miniscrews and surrounding bone evaluated by 3-dimensional finite element analysis
    Suzuki, Akihiro
    Masuda, Taisuke
    Takahashi, Ichiro
    Deguchi, Toru
    Suzuki, Osamu
    Takano-Yamamoto, Teruko
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (06) : E273 - E280
  • [29] Investigation on Effects of Geometric Design Variable and Biomaterial Analysis on Stress Distribution for One-Piece Dental Implant - A 3D Finite Element Analysis
    Irudhayam, S. Jackson
    Venkatesan, Hariram
    ANNALES DE CHIMIE-SCIENCE DES MATERIAUX, 2024, 48 (03): : 359 - 367
  • [30] 3-DIMENSIONAL FINITE-ELEMENT ANALYSIS OF IMPLANT PROSTHESIS DURING CHEWING MOVEMENT
    NAKANO, T
    INUI, Y
    MATSUZAKI, D
    NAKANO, H
    KATO, K
    TSUKAMOTO, H
    YAMADA, S
    TAKASHIMA, F
    MARUYAMA, T
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 979 - 979