Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom

被引:19
|
作者
Tavallaei, M. A. [1 ]
Lavdas, M. K. [1 ]
Gelman, D. [1 ]
Drangova, M. [1 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, Imaging Res Labs, London, ON N6A 5B9, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Magnetic resonance imaging; Master-slave; MRI-compatible; Real-time systems; Surgical robotics; Telerobotics; Catheterization; ATRIAL-FIBRILLATION; ABLATION; TIME; PATIENT; SAFETY; MRI; ELECTROPHYSIOLOGY; VISUALIZATION; EXPERIENCE; EFFICACY;
D O I
10.1007/s11548-015-1337-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To facilitate MRI-guided catheterization procedures, we present an MRI-compatible remote catheter navigation system that allows remote navigation of steerable catheters with 3 degrees of freedom. The system consists of a user interface (master), a robot (slave), and an ultrasonic motor control servomechanism. The interventionalist applies conventional motions (axial, radial and plunger manipulations) on an input catheter in the master unit; this user input is measured and used by the servomechanism to control a compact catheter manipulating robot, such that it replicates the interventionalist's input motion on the patient catheter. The performance of the system was evaluated in terms of MRI compatibility (SNR and artifact), feasibility of remote navigation under real-time MRI guidance, and motion replication accuracy. Real-time MRI experiments demonstrated that catheter was successfully navigated remotely to desired target references in all 3 degrees of freedom. The system had an absolute value error of 1 mm in axial catheter motion replication over 30 mm of travel and for radial catheter motion replication over . The worst case SNR drop was observed to be 3 %; the robot did not introduce any artifacts in the MR images. An MRI-compatible compact remote catheter navigation system has been developed that allows remote navigation of steerable catheters with 3 degrees of freedom. The proposed system allows for safe and accurate remote catheter navigation, within conventional closed-bore scanners, without degrading MR image quality.
引用
收藏
页码:1537 / 1545
页数:9
相关论文
共 50 条
  • [1] Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom
    M. A. Tavallaei
    M. K. Lavdas
    D. Gelman
    M. Drangova
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 1537 - 1545
  • [2] A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System
    Tavallaei, Mohammad Ali
    Thakur, Yogesh
    Haider, Syed
    Drangova, Maria
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (04) : 899 - 905
  • [3] CathROB: A Highly Compact and Versatile Remote Catheter Navigation System
    Cercenelli, Laura
    Bortolani, Barbara
    Marcelli, Emanuela
    APPLIED BIONICS AND BIOMECHANICS, 2017, 2017
  • [4] Design and Performance Evaluation of a Remote Catheter Navigation System
    Thakur, Yogesh
    Bax, Jeffrey S.
    Holdsworth, David W.
    Drangova, Maria
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (07) : 1901 - 1908
  • [5] Catheter Ablation of Complex Tachyarrhythmias Using Remote Magnetic Catheter Navigation System
    Nakagawa, Hiroshi
    Natale, Andrea
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 : S3 - S4
  • [6] Mapping and Ablation of the Pulmonary Veins and Cavo-Tricuspid Isthmus With a Magnetic Resonance Imaging-Compatible Externally Irrigated Ablation Catheter and Integrated Electrophysiology System
    Ganesan, Anand N.
    Selvanayagam, Joseph B.
    Mahajan, Rajiv
    Grover, Suchi
    Nayyar, Sachin
    Brooks, Anthony G.
    Finnie, John
    Sunnarborg, Daniel
    Lloyd, Thomas
    Chakrabarty, Adhiraj
    Abed, Hany S.
    Sanders, Prashanthan
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (06): : 1136 - 1142
  • [7] Magnetic resonance imaging-compatible, three-degrees-of-freedom joystick for surgical robot
    Harja, Juha
    Tikkanen, Jussi
    Sorvoja, Hannu
    Myllyla, Risto
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (04): : 365 - 371
  • [8] Magnetic resonance imaging-compatible circular mapping catheter: an in vivo feasibility and safety study
    Elbes, Delphine
    Magat, Julie
    Govari, Assaf
    Ephrath, Yaron
    Vieillot, Delphine
    Beeckler, Christopher
    Weerasooriya, Rukshen
    Jais, Pierre
    Quesson, Bruno
    EUROPACE, 2017, 19 (03): : 458 - 464
  • [9] Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation
    Luethje, Lars
    Vollmann, Dirk
    Seegers, Joachim
    Dorenkamp, Marc
    Sohns, Christian
    Hasenfuss, Gerd
    Zabel, Markus
    CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (11) : 1003 - 1011
  • [10] Long-term outcomes of the current remote magnetic catheter navigation technique for ablation of atrial fibrillation
    Yuan, Shiwen
    Holmqvist, Fredrik
    Kongstad, Ole
    Jensen, Steen M.
    Wang, Lingwei
    Ljungstrom, Erik
    Hertervig, Eva
    Borgquist, Rasmus
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2017, 51 (06) : 308 - 315