Does Pelvic Orientation Influence Wear Measurement of the Acetabular Cup in Total Hip Arthroplasty-An Experimental Study

被引:4
作者
Wu, Junzhe [1 ,2 ]
Taylor, Dominic [3 ]
Forst, Raimund [1 ]
Seehaus, Frank [1 ,4 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Fac Med, Dept Orthopaed Surg, D-91054 Erlangen, Germany
[2] Fujian Med Univ, Affiliated Hosp 2, Dept Orthopaed Surg, Quanzhou 362000, Peoples R China
[3] Hosp Coburg, Dept Orthopaed & Trauma Surg, D-96450 Coburg, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Trauma & Orthopaed Surg, D-91054 Erlangen, Germany
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 21期
关键词
polyethylene wear; roentgen stereophotogrammetric analysis; total hip arthroplasty; precision; accuracy; pelvic orientation; POLYETHYLENE WEAR; RADIOGRAPHIC METHODS; FOLLOW-UP; ACCURACY; VALIDATION; LONG;
D O I
10.3390/app112110014
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Roentgen stereophotogrammetric analysis (RSA) is the gold standard to detect in vivo material wear of the bearing couples in hip arthroplasty. Some surgical planning tools offer the opportunity to detect wear by using standard a.p. radiographs (2D(wear)), whilst RSA (3D(wear)) needs a special radiological setup. The aims of this study are to prove the interchangeable applicability of a 2D(wear) approach next to RSA and to assess the influence of different pelvic positions on measurement outcomes. An implant-bone model was used to mimic three different wear scenarios in seven pelvic-femur alignment positions. RSA and a.p. radiographs of the reference and a follow-up (simulated wear) pose were acquired. Accuracy and precision were worse for the 2D(wear) approach (0.206 mm; 0.159 mm) in comparison to the 3D(wear) approach (0.043 mm; 0.017 mm). Changing the pelvic position significantly influenced the 2D(wear) results (4 of 7, p < 0.05), whilst 3D(wear) results showed almost no change. The 3D(wear) is superior to the 2D(wear) approach, as it is less susceptible to changes in pelvic position. However, the results suggest that a 2D(wear) approach may be an alternative method if the wear present is in the range of 100-500 mu m and a.p. radiographs are available with the pelvis projected in a neutral position.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A Comparison Between Imageless Navigated and Manual Freehand Technique Acetabular Cup Placement in Total Hip Arthroplasty
    Hohmann, Erik
    Bryant, Adam
    Tetsworth, Kevin
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (07) : 1078 - 1082
  • [42] Efficacy of a Pelvic Lateral Positioner With a Mechanical Cup Navigator Based on the Anatomical Pelvic Plane in Total Hip Arthroplasty
    Iwakiri, Kentaro
    Kobayashi, Akio
    Ohta, Yoichi
    Minoda, Yukihide
    Takaoka, Kunio
    Nakamura, Hiroaki
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (12) : 3659 - 3664
  • [43] Accurate cup placement using a portable navigation system during total hip arthroplasty based on pelvic orientation in the lateral decubitus position
    Tsukamoto, Manabu
    Kawasaki, Makoto
    Suzuki, Hitoshi
    Fujitani, Teruaki
    Uchida, Soshi
    Sakai, Akinori
    [J]. ARTIFICIAL ORGANS, 2022, 46 (12) : 2412 - 2422
  • [44] Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: A cadaver study
    Lin, Fang
    Lim, Dohyung
    Wixson, Richard L.
    Milos, Steven
    Hendrix, Ronald W.
    Makhsous, Mohsen
    [J]. CLINICAL BIOMECHANICS, 2008, 23 (08) : 1004 - 1011
  • [45] Excessive polyethylene wear and acetabular bone defects from standard use of a hooded acetabular insert in total hip arthroplasty
    Gerhardt, Davey M. J. M.
    Sanders, Rick J. M.
    de Visser, Enrico
    van Susante, Job L. C.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1585 - 1590
  • [46] Does rotational acetabular osteotomy affect subsequent total hip arthroplasty?
    Fukui, Kiyokazu
    Kaneuji, Ayumi
    Sugimori, Tanzo
    Ichiseki, Toru
    Matsumoto, Tadami
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (03) : 407 - 415
  • [47] Does Fluoroscopy Improve Acetabular Component Placement in Total Hip Arthroplasty?
    Beamer, Brandon S.
    Morgan, Jordan H.
    Barr, Christopher
    Weaver, Michael J.
    Vrahas, Mark S.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (12) : 3953 - 3962
  • [48] Navigating the Reaming of the Acetabular Cavity in Total Hip Arthroplasty: Does it Improve Implantation Accuracy?
    Pagkalos, Joseph
    Chaudary, Muhammad Imran
    Davis, Edward T.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 1749 - 1752
  • [49] Influence of Spinopelvic Alignment on Pelvic Tilt after Total Hip Arthroplasty
    Kanto, Makoto
    Maruo, Keishi
    Tachibana, Toshiya
    Fukunishi, Shigeo
    Nishio, Shoji
    Takeda, Yu
    Arizumi, Fumihiro
    Kusuyama, Kazuki
    Kishima, Kazuya
    Yoshiya, Shinichi
    [J]. ORTHOPAEDIC SURGERY, 2019, 11 (03) : 438 - 442
  • [50] Prior unilateral total hip arthroplasty does not influence the outcome of ipsilateral total knee arthroplasty
    Asensio-Pascual, Alfredo
    Lizaur-Utrilla, Alejandro
    Vizcaya-Moreno, M. Flores
    Miralles-Munoz, Fancisco A.
    Lopez-Prats, Fernando A.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) : 1452 - 1457