Biomechanical comparison of tuberosity-based proximal humeral locking plate compared to standard proximal humeral locking plate in varus cantilever bending

被引:2
作者
Saunders, Patrick E. [1 ,2 ]
Castaneda, Paulo [1 ]
Walker, Robert [1 ]
McKee, Michael D. [1 ]
机构
[1] Univ Arizona, Coll Med Phoenix, Dept Orthopaed Surg, 1111 E McDowell Rd, Phoenix, AZ 85006 USA
[2] 3720 East Orange Dr, Phoenix, AZ 85018 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2022年 / 53卷 / 11期
关键词
Proximal humerus fracture; Biomechanical; Varus collapse; Tuberosity; Locking plate; OPEN REDUCTION; INTERNAL-FIXATION; LOCKED PLATE; FRACTURES; EPIDEMIOLOGY; MULTICENTER; DENSITY; SCREWS;
D O I
10.1016/j.injury.2022.08.042
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: In a prior biomechanical study using a tuberosity-based proximal humeral locking plate (TBP) an improvement in greater tuberosity (GT) fixation strength with the TBP compared to a standard proximal humeral locking plate (PHLP) was demonstrated. The purpose of this study is to compare the TBP to the PHLP with a simulated calcar gap fracture under cyclic varus cantilever forces. Methods: Seven matched pairs of cadaveric humeri were studied and 11A2.3 proximal humerus fractures were created by a 1 cm gap osteotomy at the surgical neck. Matched pairs were randomized for fixation using either a PHLP or a TBP. The proximal articular aspect of the humerus was potted and secured to the base of a load frame. The shaft was subjected to cyclic varus cantilever loading with a roller positioned 8 cm from the osteotomy. Change in vertical displacement of the diaphyseal fragment was monitored and digital images were obtained. Failure was defined as vertical displacement greater than 20 mm. Specimens not exhibiting failure over the course of 10,0 0 0 cycles were then loaded to 20 mm of vertical displacement. Reactant forces of the specimens at these displacements were recorded. Results: Four/seven TBP specimens and four/seven PHLP specimens survived 10,0 0 0 cycles. The average cycles to failure for TBP specimens was 7325 cycles and 5715 cycles for PHLP specimens ( p = 0.525). For the specimens that survived 10,0 0 0 cycles, the decrease in calcar gap was superior in the TBP specimens ( p = 0.018). A similar trend was seen when these specimens were loaded to failure where the percent calcar gap recovery was higher for the TBP at 74.71 +/- 10.07% versus 53.22 +/- 30.35% for the PHLP ( p = 0.072). In specimens that were loaded to failure after survival of 10,0 0 0 cycles the average stiffness of the TBP construct was 20.51 N/mm, and 11.74 N/mm for the PHLP construct ( p = 0.024). Conclusion: In addition to superior GT fixation shown in a prior study, the TBP construct demonstrates significantly greater stiffness at the neck fracture compared to the PHLP, when loaded to failure. In addition, there was a trend towards less collapse in this calcar gap model. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3650 / 3654
页数:5
相关论文
共 19 条
[1]   Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter Analysis [J].
Brunner, Felix ;
Sommer, Christoph ;
Bahrs, Christian ;
Hettwinkel, Rainer ;
Hafner, Christian ;
Rillmann, Paavo ;
Kohut, Georges ;
Ekelund, Anders ;
Muller, Mathias ;
Audige, Laurent ;
Babst, Reto .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (03) :163-172
[2]   The epidemiology of proximal humeral fractures [J].
Court-Brown, CM ;
Garg, A ;
McQueen, MM .
ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (04) :365-371
[3]   Biomechanical Comparison of 3 Inferiorly Directed Versus 3 Superiorly Directed Locking Screws on Stability in a 3-Part Proximal Humerus Fracture Model [J].
Donohue, David M. ;
Santoni, Brandon G. ;
Stoops, T. Kyle ;
Tanner, Gregory ;
Diaz, Miguel A. ;
Mighell, Mark .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (06) :306-312
[4]   Epidemiology of proximal humerus fractures [J].
Launonen, Antti P. ;
Lepola, Vesa ;
Saranko, Aino ;
Flinkkila, Tapio ;
Laitinen, Minna ;
Mattila, Ville M. .
ARCHIVES OF OSTEOPOROSIS, 2015, 10 (01) :1-5
[5]   Effect of screw placement on fixation in the humeral head [J].
Liew, ASL ;
Johnson, JA ;
Patterson, SD ;
King, GJW ;
Chess, DG .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2000, 9 (05) :423-426
[6]   Displacement/Screw cutout after open reduction and locked plate fixation of humeral fractures [J].
Owsley, Kevin C. ;
Gorczyca, John T. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (02) :233-240
[7]   Failure to restore the calcar and locking screw cross-threading predicts varus collapse in proximal humerus fracture fixation [J].
Padegimas, Eric M. ;
Chang, Gerard ;
Namjouyan, Kamran ;
Namdari, Surena .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (02) :291-295
[8]   Epidemiology of proximal humeral fractures: a detailed survey of 711 patients in a metropolitan area [J].
Passaretti, Daniele ;
Candela, Vittorio ;
Sessa, Pasquale ;
Gumina, Stefano .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (12) :2117-2124
[9]  
Ricchetti Eric T, 2010, J Shoulder Elbow Surg, V19, P66, DOI 10.1016/j.jse.2010.01.001
[10]   Epidemiology of proximal humerus fractures managed in a trauma center [J].
Roux, A. ;
Decroocq, L. ;
El Batti, S. ;
Bonnevialle, N. ;
Moineau, G. ;
Trojani, C. ;
Boileau, P. ;
de Peretti, F. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (06) :715-719