New cylindrical silicon drift detectors have been designed, fabricated and tested. They comprise an integrated on-chip amplifier system with continuous reset, on-chip voltage divider, electron accumulation layer stabilizer, large area, homogeneous radiation entrance window and a drain for surface generated leakage current. The test of the 3.5 mm(2) large individual devices, which have also been grouped together to form a sensitive area up to 21 mm(2) have shown the following spectroscopic results: at room temperature (300 K) the devices have shown a full width at half maximum at the Mn-K alpha line of a radioactive Fe-55 source of 225 eV with shaping times of 250 to 500 ns. At -20 degrees C the resolution improves to 152 eV at 2 mu s Gaussian shaping. At temperatures below 200 K the energy resolution is below 140 eV. With the implementation of a digital filtering system the resolution approaches 130 eV. The system was operated with count rates up to 800 000 counts per second and per readout node, still conserving the spectroscopic qualities of the detector system.
引用
收藏
页码:346 / 351
页数:6
相关论文
共 50 条
  • [1] Silicon drift detectors for high count rate X-ray spectroscopy at room temperature
    Lechner, P
    Fiorini, C
    Hartmann, R
    Kemmer, J
    Krause, N
    Leutenegger, P
    Longoni, A
    Soltau, H
    Stötter, D
    Stötter, R
    Strüder, L
    Weber, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 281 - 287
  • [2] ROOM-TEMPERATURE, HIGH-RESOLUTION X-RAY SPECTROSCOPY WITH SILICON DRIFT CHAMBERS
    PINOTTI, E
    LONGONI, A
    GAMBELLI, M
    STRUDER, L
    LECHNER, P
    VANZANTHIER, C
    KRANER, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (01) : 12 - 16
  • [3] Silicon Drift Detectors and CUBE Preamplifiers for High-Resolution X-ray Spectroscopy
    Quaglia, R.
    Bombelli, L.
    Busca, P.
    Fiorini, C.
    Occhipinti, M.
    Giacomini, G.
    Ficorella, F.
    Picciotto, A.
    Piemonte, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 221 - 227
  • [4] HIGH-RESOLUTION X-RAY SPECTROSCOPY WITH SILICON DRIFT DETECTORS AND INTEGRATED ELECTRONICS
    BERTUCCIO, G
    SAMPIETRO, M
    FAZZI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 538 - 542
  • [5] Optimized readout methods of silicon drift detectors for high-resolution X-ray spectroscopy
    Niculae, A.
    Lechner, P.
    Soltau, H.
    Lutz, G.
    Strueder, L.
    Fiorini, C.
    Longoni, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 336 - 342
  • [6] SEMICONDUCTOR DRIFT DETECTORS FOR HIGH-RESOLUTION X-RAY SPECTROSCOPY
    CASTOLDI, A
    SAMPIETRO, M
    SENSORS AND ACTUATORS A-PHYSICAL, 1992, 31 (1-3) : 245 - 249
  • [7] Room temperature X- and gamma-ray spectroscopy with silicon drift detectors
    Strüder, L
    Hartmann, R
    Kemmer, S
    Krause, N
    Stötter, D
    Lutz, G
    Solc, P
    Holl, P
    Lechner, P
    Leutenegger, P
    Kemmer, J
    Soltau, H
    Stötter, R
    Weber, U
    Castoldi, A
    Fiorini, C
    Gatti, E
    Guazzoni, C
    Longoni, A
    Sampietro, M
    HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 : 29 - 47
  • [8] Multichannel silicon drift detectors for X-ray spectroscopy
    Lechner, P
    Buttler, W
    Fiorini, C
    Hartmann, R
    Kemmer, J
    Krause, N
    Leutenegger, P
    Longoni, A
    Soltau, H
    Stötter, D
    Stötter, R
    Strüder, L
    Weber, U
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 592 - 599
  • [9] A HIGH-RESOLUTION SILICON DRIFT CHAMBER FOR X-RAY SPECTROSCOPY
    GAUTHIER, C
    GOULON, J
    MOGUILINE, E
    ELLEAUME, P
    FEITE, S
    GABURRO, Z
    LONGONI, A
    GATTI, E
    DRESSLER, P
    LAMPERT, MO
    HENCK, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (01): : 258 - 262
  • [10] SILICON CARBIDE MICROSTRIP DETECTORS FOR HIGH RESOLUTION X-RAY SPECTROSCOPY
    Bertuccio, Giuseppe
    Puglisi, Donatella
    Lanzieri, Claudio
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 653 - 657