Evaluation of the degenerative lumbar osseous morphology using zero echo time magnetic resonance imaging (ZTE-MRI)

被引:15
作者
Hou, Bowen [1 ]
Liu, Chanyuan [1 ]
Li, Yitong [1 ]
Xiong, Yan [1 ]
Wang, Jingyi [1 ]
Zhang, Peisen [2 ]
Liu, Jianyi [3 ]
Liu, Weiyin Vivian [4 ]
Li, Xiaoming [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, 1095 Jiefang Rd, Wuhan 430030, Hubei, Peoples R China
[2] South China Univ Technol, Guangzhou Peoples Hosp 1, Sch Med, Dept Rehabil Med, Guangzhou, Peoples R China
[3] Renhe Shijia, Wuhan, Peoples R China
[4] GE Healthcare, 4th Floor,Bldg 1,1 Courtyard,Tongji South Rd, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; Lumbar; Bone; ZTE; COMPUTED-TOMOGRAPHY; OSTEOARTHRITIS; TROPISM; AGREEMENT;
D O I
10.1007/s00586-021-07099-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose To determine and compare the performance of zero echo imaging (ZTE) with conventional MRI sequences on lumbar osseous morphology in patients suspected with lumbar degeneration with multi-slice computed tomography (MSCT) as standard reference. Methods 22 subjects with concerned lumbar degeneration were recruited. All subjects were scanned with ZTE sequence after routine conventional MR sequences on a 3.0 T system and also received MSCT examination. Image quality was assessed. The quantitative and qualitative parameters of lumbar osseous morphology on MSCT, ZTE and MRI images were evaluated by three musculoskeletal radiologists independently. Inter-reader and inter-modality reliability and the difference between the modalities were calculated. Results There was no difference for the osseous parameters between modalities, including axial orientation (p = 0.444), IAD (p = 0.381), lateral recess (p = 0.370), pedicle width (p = 0.067), pedicle height (p = 0.056), and osteophyte grade (p = 0.052). The measurement of the foramina diameter was statistically different between conventional MRI and MSCT (p < 0.05) but not between the MSCT and ZTE (p = 0.660). Conventional MRI was more likely to miss cortical bone abnormalities. ZTE appeared blurrier in cortical bone than MSCT, especially in cases with severe lumbar degeneration. The inter-reader agreement between MSCT and ZTE-MRI was higher than between MSCT and conventional MRI. Conclusions ZTE-MRI could offer more cortical bone details than conventional MRI images and might be a valid alternative to CT for lumbar osseous morphology assessment to some extent.
引用
收藏
页码:792 / 800
页数:9
相关论文
共 50 条
  • [21] Correction of Excitation Profile in Zero Echo Time (ZTE) Imaging Using Quadratic Phase-Modulated RF Pulse Excitation and Iterative Reconstruction
    Li, Cheng
    Magland, Jeremy F.
    Seifert, Alan C.
    Wehrli, Felix W.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (04) : 961 - 969
  • [22] Study of bubble dynamics in gas-solid fluidized beds using ultrashort echo time (UTE) magnetic resonance imaging (MRI)
    Fabich, Hilary T.
    Sederman, Andrew J.
    Holland, Daniel J.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2017, 172 : 476 - 486
  • [23] The prevalence of degenerative or incidental findings in the lumbar spine of pediatric patients: a study using magnetic resonance imaging as a screening tool
    Julio Urrutia
    Tomas Zamora
    Carlos Prada
    [J]. European Spine Journal, 2016, 25 : 596 - 601
  • [24] Evaluation of osseous cervical foraminal stenosis in spinal radiculopathy using susceptibility-weighted magnetic resonance imaging
    Engel, Guenther
    Bender, Yvonne Y.
    Adams, Lisa C.
    Boker, Sarah M.
    Fahlenkamp, Ute L.
    Wagner, Moritz
    Diederichs, Gerd
    Hamm, Bernd
    Makowski, Marcus R.
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (04) : 1855 - 1862
  • [25] Evaluation of osseous cervical foraminal stenosis in spinal radiculopathy using susceptibility-weighted magnetic resonance imaging
    Guenther Engel
    Yvonne Y. Bender
    Lisa C. Adams
    Sarah M. Boker
    Ute L. Fahlenkamp
    Moritz Wagner
    Gerd Diederichs
    Bernd Hamm
    Marcus R. Makowski
    [J]. European Radiology, 2019, 29 : 1855 - 1862
  • [26] Time-to-echo optimization for spin echo magnetic resonance imaging of liver metastasis using superparamagnetic iron oxide particles
    Alger, JR
    Harreld, JH
    Chen, S
    Mintorovitch, J
    Lu, DSK
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) : 586 - 594
  • [27] Silent volumetric multi-contrast 7 Tesla MRI of ocular tumors using Zero Echo Time imaging
    Beenakker, Jan-Willem M.
    Wezel, Joep
    Groen, Jan
    Webb, Andrew G.
    Boernert, Peter
    [J]. PLOS ONE, 2019, 14 (09):
  • [28] In Vitro Imaging of Kidney Stones Using Ultra-short Echo-time Magnetic Resonance
    Ibrahim, El-Sayed
    Pooley, Robert
    Cernigliaro, Joseph
    Bridges, Mellena
    Giesbrandt, Jamie
    Williams, James
    Haley, William
    [J]. 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1466 - 1469
  • [29] Respiratory motion–resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
    Kyungsoo Bae
    Kyung Nyeo Jeon
    Moon Jung Hwang
    Joon Sung Lee
    Sung Eun Park
    Ho Cheol Kim
    Anne Menini
    [J]. European Radiology, 2020, 30 : 5130 - 5138
  • [30] Quantitative evaluation of equine deep digital flexor tendon morphology using magnetic resonance imaging
    Murray, RC
    Roberts, BL
    Schramme, MC
    Dyson, SJ
    Branch, M
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2004, 45 (02) : 103 - 111