Proximal nerve MR neurography with diffusion tensor imaging in differentiating subtypes of Charcot-Marie-Tooth disease

被引:2
|
作者
Sun, Xingwen [1 ]
Liu, Xiaoxuan [2 ]
Zhao, Qiang [1 ]
Zhang, Mengze [1 ]
Zhang, Lihua [1 ]
Yuan, Huishu [1 ]
机构
[1] Peking Univ Third Hosp, Dept Radiol, 49 North Garden Rd, Beijing 100191, Peoples R China
[2] Peking Univ Third Hosp, Dept Neurol, 49 North Garden Rd, Beijing 100191, Peoples R China
关键词
Magnetic resonance imaging; Diffusion tensor imaging; Charcot-Marie-Tooth disease; Spinal nerve root; Sciatic nerve; NATURAL-HISTORY; NEUROPATHY; POLYNEUROPATHY; DIAGNOSIS; MOTOR;
D O I
10.1007/s00330-021-08506-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the feasibility of proximal nerve MR neurography with diffusion tensor imaging (DTI) for differentiating Charcot-Marie-Tooth (CMT) 1A, CMT2, and healthy controls. Methods The diameters, fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) of L4-L5 nerve roots, femoral nerve (FN), and sciatic nerve (SN) were compared. Receiver operating characteristic (ROC) curve analyses were conducted to evaluate the diagnostic performance. DeLong's tests were applied to compare multiple ROC curves. Intraclass correlation coefficients were calculated for interobserver agreement assessment. Results The diameters of the L4 nerve root, L5 nerve root, and SN of CMT1A patients were significantly larger than those of CMT2 patients and healthy controls. The FA values of all measured proximal nerves were significantly higher in controls (0.46 +/- 0.09, 0.46 +/- 0.08, 0.45 +/- 0.07, and 0.48 +/- 0.08) than in CMT1A patients (0.30 +/- 0.09, 0.29 +/- 0.06, 0.35 +/- 0.08, and 0.29 +/- 0.09). The FA values of the L5 nerve root, FN, and SN were significantly higher in controls (0.46 +/- 0.08, 0.45 +/- 0.07, and 0.48 +/- 0.08) than in CMT2 patients (0.36 +/- 0.06, 0.34 +/- 0.07, and 0.34 +/- 0.10). The MD and RD values of the L5 nerve root in CMT1A patients (1.59 +/- 0.21 and 1.37 +/- 0.21) were higher than those in CMT2 patients (1.31 +/- 0.17 and 1.05 +/- 0.14). The AUCs of the above parameters ranged from 0.780 to 1.000. For the measurements of nerve diameters, the ICC ranged from 0.91 to 0.97. For the measurements of DTI metrics, the ICC ranged from 0.87 to 0.97. Conclusions MR neurography with DTI is able to differentiate CMT1A patients, CMT2 patients, and healthy controls.
引用
收藏
页码:3855 / 3862
页数:8
相关论文
共 50 条
  • [21] Dynamin 2 in Charcot-Marie-Tooth Disease
    Tanabe, Kenji
    Takei, Kohji
    ACTA MEDICA OKAYAMA, 2012, 66 (03) : 183 - 190
  • [22] Diagnosis of Charcot-Marie-Tooth Disease
    Banchs, Isabel
    Casasnovas, Carlos
    Alberti, Antonia
    De Jorge, Laura
    Povedano, Monica
    Montero, Jordi
    Antonio Martinez-Matos, Juan
    Volpini, Victor
    JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2009,
  • [23] Update on Charcot-Marie-Tooth Disease
    Ágnes Patzkó
    Michael E. Shy
    Current Neurology and Neuroscience Reports, 2011, 11 : 78 - 88
  • [24] Intermediate Charcot-Marie-Tooth disease
    Liu, Lei
    Zhang, Ruxu
    NEUROSCIENCE BULLETIN, 2014, 30 (06) : 999 - 1009
  • [25] Update on Charcot-Marie-Tooth Disease
    Patzko, Agnes
    Shy, Michael E.
    CURRENT NEUROLOGY AND NEUROSCIENCE REPORTS, 2011, 11 (01) : 78 - 88
  • [26] The causes of Charcot-Marie-Tooth disease
    P. Young
    U. Suter
    Cellular and Molecular Life Sciences CMLS, 2003, 60 : 2547 - 2560
  • [27] The causes of Charcot-Marie-Tooth disease
    Young, P
    Suter, U
    CELLULAR AND MOLECULAR LIFE SCIENCES, 2003, 60 (12) : 2547 - 2560
  • [28] Intermediate Charcot-Marie-Tooth disease
    Lei Liu
    Ruxu Zhang
    NeuroscienceBulletin, 2014, 30 (06) : 999 - 1009
  • [29] Intermediate Charcot-Marie-Tooth disease
    Lei Liu
    Ruxu Zhang
    Neuroscience Bulletin, 2014, 30 : 999 - 1009
  • [30] Update on Charcot-Marie-Tooth disease
    Gutmann, Laurie
    Shy, Michael
    CURRENT OPINION IN NEUROLOGY, 2015, 28 (05) : 462 - 467