Implantable cardioverter-defibrillator lead revision following left ventricular assist device implantation

被引:1
作者
Black-Maier, Eric [1 ]
Lewis, Robert K. [1 ]
Rehorn, Michael [1 ]
Loungani, Rahul [1 ]
Friedman, Daniel J. [2 ]
Frazier-Mills, Camille [1 ]
Jackson, Kevin P. [1 ]
Atwater, Brett D. [1 ]
Milano, Carmelo A. [3 ]
Schroder, Jacob N. [3 ]
Pokorney, Sean D. [1 ]
Piccini, Jonathan P. [1 ]
机构
[1] Duke Univ, Med Ctr, Div Cardiol, Durham, NC USA
[2] Yale Univ, Sch Med, Div Electrophysiol, New Haven, CT USA
[3] Duke Univ, Med Ctr, Div Cardiothorac Surg, Durham, NC USA
关键词
implantable cardioverter-defibrillator; lead dysfunction; lead revision; left ventricular assist device;
D O I
10.1111/jce.14487
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Lead dysfunction can lead to serious consequences including failure to treat ventricular tachycardia or fibrillation (VT/VF). The incidence and mechanisms of lead dysfunction following left ventricular assist device (LVAD) implantation are not well-described. We sought to determine the incidence, mechanisms, timing, and complications of right ventricular lead dysfunction requiring revision following LVAD implantation. Methods Retrospective observational chart review of all LVAD recipients with pre-existing implantable cardioverter-defibrillator (ICD) from 2009 to 2018 was performed including device interrogation reports, laboratory and imaging data, procedural reports, and clinical outcomes. Results Among 583 patients with an ICD in situ undergoing LVAD implant, the median (interquartile range) age was 62.5 (15.7) years, 21% were female, and the types of LVADs included HeartWare HVAD (26%), HeartMate II (52%), and HeartMate III (22%). Right ventricular lead revision was performed in 38 patients (6.5%) at a median (25th, 75th) of 16.4 (3.6, 29.2) months following LVAD. Mechanisms of lead dysfunction included macrodislodgement (n = 4), surgical lead injury (n = 4), recall (n = 3), insulation failure (n = 8) or conductor fracture (n = 7), and alterations in the lead-myocardial interface (n = 12). Undersensing requiring revision occurred in 22 (58%) cases. Clinical sequelae of undersensing included failure to detect VT/VF (n = 4) and pacing-induced torsade de pointes (n = 1). Oversensing occurred in 12 (32%) and sequelae included inappropriate antitachycardia pacing ([ATP], n = 8), inappropriate ICD shock (n = 6), and ATP-induced VT (n = 1). Conclusion The incidence of right ventricular lead dysfunction following LVAD implantation is significant and has important clinical sequelae. Physicians should remain vigilant for lead dysfunction after LVAD surgery and test lead function before discharge.
引用
收藏
页码:1509 / 1518
页数:10
相关论文
共 50 条
[31]   Safe delivery of lung stereotactic body radiation therapy in a patient with a left ventricular assist device and implantable cardioverter defibrillator [J].
Ostertag-Hill, Claire A. ;
Mudd, James ;
Werle, Daniel P. ;
Tieu, Brandon H. ;
Nabavizadeh, Nima .
CLINICAL CASE REPORTS, 2018, 6 (09) :1704-1707
[32]   Implantable cardioverter-defibrillator and cardiac resynchronization therapy in patients with left ventricular noncompaction [J].
Kobza, Richard ;
Steffel, Jan ;
Erne, Paul ;
Schoenenberger, Andreas W. ;
Huerlimann, David ;
Luescher, Thomas F. ;
Jenni, Rolf ;
Duru, Firat .
HEART RHYTHM, 2010, 7 (11) :1545-1549
[33]   Testing the implantable cardioverter-defibrillator after implantation -: Is it necessary? [J].
Sandstedt, Bengt ;
Gottfridsson, Christer ;
Nystrom, Britta ;
Edvardsson, Nils .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (08) :985-991
[34]   Electrophysiological interactions between implantable cardioverter defibrillators and left ventricular assist device [J].
Maffe, Stefano ;
Perucca, Antonello ;
Signorotti, Fabiana ;
Pistono, Massimo ;
Paffoni, Paola ;
Parravicini, Umberto ;
Dellavesa, Pierfranco ;
Cucchi, Lorenzo ;
Paino, Anna Maria ;
Zenone, Franco ;
Pardo, Nicolo Franchetti ;
Bielli, Massimo ;
Zanetta, Marco .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (03) :620-623
[35]   The effect of device advisories on implantable cardioverter-defibrillator therapy [J].
Amin M.S. ;
Ellenbogen K.A. .
Current Cardiology Reports, 2010, 12 (5) :361-366
[36]   Implantable defibrillator therapy for ventricular tachyarrhythmia in left ventricular assist device patients [J].
Oswald, Hanno ;
Schultz-Wildelau, Claudia ;
Gardiwal, Ajmal ;
Luesebrink, Ulrich ;
Koenig, Thorben ;
Meyer, Anna ;
Duncker, David ;
Pichlmaier, Maximilian A. ;
Klein, Gunnar ;
Strueber, Martin .
EUROPEAN JOURNAL OF HEART FAILURE, 2010, 12 (06) :593-599
[37]   Implantation of the Subcutaneous Implantable Cardioverter-Defibrillator An Evaluation of 4 Implantation Techniques [J].
Brouwer, Tom F. ;
Miller, Marc A. ;
Quast, Anne-Floor B. E. ;
Palaniswamy, Chandrasekar ;
Dukkipati, Srinivas R. ;
Reddy, Vivek ;
Wilde, Arthur A. ;
Willner, Jonathan M. ;
Knops, Reinoud E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2017, 10 (01)
[38]   Troubleshooting electromagnetic interference in a patient with centrifugal flow left ventricular assist device and subcutaneous implantable cardioverter defibrillator [J].
Ahmed, Asim S. ;
Patel, Parin J. ;
Bagga, Shiv ;
Gilge, Jasen L. ;
Schleeter, Thomas ;
Lakhani, Baqir A. ;
Ravichandran, Ashwin K. ;
Donnelley, Steve ;
Allavatam, Venu ;
Prystowsky, Eric N. ;
Padanilam, Benzy J. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (03) :477-481
[39]   Celivarone in patients with an implantable cardioverter-defibrillator: Adjunctive therapy for the reduction of ventricular arrhythmia-triggered implantable cardioverter-defibrillator interventions [J].
Gojkovic, Olivera ;
Aliot, Etienne M. ;
Capucci, Alessandro ;
Connolly, Stuart J. ;
Crijns, Harry ;
Hohnloser, Stefan H. ;
Kulakowski, Piotr ;
Roy, Denis ;
Radzik, David ;
Singh, Bramah N. ;
Kowey, Peter R. .
HEART RHYTHM, 2012, 9 (02) :217-U2
[40]   Benefits of the implantable cardioverter-defibrillator [J].
Epstein, Andrew E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (14) :1122-1127