Amperometric glucose microbiosensor based on a Prussian Blue modified carbon fiber electrode for physiological applications

被引:24
|
作者
Salazar, P. [1 ]
O'Neill, R. D. [2 ]
Martin, M. [1 ]
Roche, R. [1 ]
Gonzalez-Mora, J. L. [1 ]
机构
[1] Univ La Laguna, Fac Med, Neurochem & Neuroimaging Grp, Tenerife, Spain
[2] Univ Coll Dublin, UCD Sch Chem & Chem Biol, Dublin 4, Ireland
关键词
Biosensor; Carbon fiber electrode; Brain glucose; Prussian blue; Polyphenylenediamine; ENZYME COMPOSITE BIOSENSOR; FLOW-INJECTION ANALYSIS; OXYGEN DEPENDENCE; IN-VIVO; BRAIN GLUCOSE; SENSITIVITY; DEHYDROGENASE; INTERFERENCE; GLUTAMATE; COATINGS;
D O I
10.1016/j.snb.2010.11.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Results of experiments in vitro and in vivo, using an amperometric glucose microbiosensor based on a Prussian Blue (PB) modified carbon fiber electrode with very low dimensions (similar to 10 mu m diameter), are presented. The electrocatalytic properties of the PB film enable detection of an enzymatic by-product (H2O2) at a very low applied potential: 0.0 V against SCE. The main steps during glucose microbiosensor construction were examined by cyclic voltammetry and electrochemical impedance spectroscopy. Excellent selectivity of the glucose microbiosensors against a large number of physiological interference compounds is demonstrated. Finally, microbiosensor responses during intraperitoneal injection, local infusion and local electrical stimulation showed sufficient sensitivity and stability to monitor multiphasic and reversible changes in brain ECF glucose levels during physiological experiments, illustrating the excellent properties and utility of this biosensor design in the neurosciences. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [41] Performance and mechanism of Prussian blue (PB) modified carbon felt electrode
    薛方勤
    张鸿涛
    吴春旭
    宁涛
    徐璇
    Transactions of Nonferrous Metals Society of China, 2009, 19(S3) (S3) : 594 - 599
  • [42] Performance and mechanism of Prussian blue (PB) modified carbon felt electrode
    Xue Fang-qin
    Zhang Hong-tao
    Wu Chun-xu
    Ning Tao
    Xu Xuan
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2009, 19 : S594 - S599
  • [43] Amperometric glucose biosensor based on Prussian blue-multiwall carbon nanotubes composite and hollow PtCo nanochains
    Che, Xin
    Yuan, Ruo
    Chai, Yaqin
    Li, Jingjing
    Song, Zhongju
    Li, Wenjuan
    ELECTROCHIMICA ACTA, 2010, 55 (19) : 5420 - 5427
  • [44] Cholesterol biosensor based on platinium electrode modified by Prussian blue
    Wu, XQ
    Guo, XM
    Wang, R
    Zhang, ZR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (11) : 1273 - 1275
  • [45] The Development of Reagentless Amperometric Glucose Biosensor Based on Gold Nanostructures, Prussian Blue and Glucose Oxidase
    Sakalauskiene, Laura
    Brasiunas, Benediktas
    Popov, Anton
    Kausaite-Minkstimiene, Asta
    Ramanaviciene, Almira
    BIOSENSORS-BASEL, 2023, 13 (10):
  • [46] DNA as a support for glucose oxidase immobilization at Prussian blue-modified glassy carbon electrode in biosensor preparation
    Kafi, A. K. M.
    Lee, Dong-Yun
    Park, Sang-Hyun
    Kwon, Young-Soo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2006, 6 (11) : 3539 - 3542
  • [47] Amperometric biosensor based on Prussian Blue-modified screen-printed electrode for lipase activity and triacylglycerol determination
    Rejeb, Ines Ben
    Arduini, Fabiana
    Amine, Aziz
    Gargouri, Mohamed
    Palleschi, Giuseppe
    ANALYTICA CHIMICA ACTA, 2007, 594 (01) : 1 - 8
  • [48] Glucose biosensor based on glucose oxidase immobilized in sol–gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode
    Xue-Cai Tan
    Yuan-Xin Tian
    Pei-Xiang Cai
    Xiao-Yong Zou
    Analytical and Bioanalytical Chemistry, 2005, 381 : 500 - 507
  • [49] Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrode
    Garjonyte, R
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) : 122 - 128
  • [50] Automated determination of glucose in soluble coffee using Prussian blue-glucose oxidase-Nafion® modified electrode
    de Mattos, IL
    Areias, MCD
    TALANTA, 2005, 66 (05) : 1281 - 1286