Amperometric glucose microbiosensor based on a Prussian Blue modified carbon fiber electrode for physiological applications

被引:24
|
作者
Salazar, P. [1 ]
O'Neill, R. D. [2 ]
Martin, M. [1 ]
Roche, R. [1 ]
Gonzalez-Mora, J. L. [1 ]
机构
[1] Univ La Laguna, Fac Med, Neurochem & Neuroimaging Grp, Tenerife, Spain
[2] Univ Coll Dublin, UCD Sch Chem & Chem Biol, Dublin 4, Ireland
关键词
Biosensor; Carbon fiber electrode; Brain glucose; Prussian blue; Polyphenylenediamine; ENZYME COMPOSITE BIOSENSOR; FLOW-INJECTION ANALYSIS; OXYGEN DEPENDENCE; IN-VIVO; BRAIN GLUCOSE; SENSITIVITY; DEHYDROGENASE; INTERFERENCE; GLUTAMATE; COATINGS;
D O I
10.1016/j.snb.2010.11.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Results of experiments in vitro and in vivo, using an amperometric glucose microbiosensor based on a Prussian Blue (PB) modified carbon fiber electrode with very low dimensions (similar to 10 mu m diameter), are presented. The electrocatalytic properties of the PB film enable detection of an enzymatic by-product (H2O2) at a very low applied potential: 0.0 V against SCE. The main steps during glucose microbiosensor construction were examined by cyclic voltammetry and electrochemical impedance spectroscopy. Excellent selectivity of the glucose microbiosensors against a large number of physiological interference compounds is demonstrated. Finally, microbiosensor responses during intraperitoneal injection, local infusion and local electrical stimulation showed sufficient sensitivity and stability to monitor multiphasic and reversible changes in brain ECF glucose levels during physiological experiments, illustrating the excellent properties and utility of this biosensor design in the neurosciences. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [31] Biosensors Based On Prussian Blue Modified Carbon Fibers Electrodes for Monitoring Lactate in The Extracellular Space of Brain Tissue
    Salazar, P.
    Martin, M.
    O'Neill, R. D.
    Roche, R.
    Gonzalez-Mora, J. L.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (07): : 5910 - 5926
  • [32] Amperometric glucose biosensors based on integration of glucose oxidase onto Prussian blue/carbon nanotubes nanocomposite electrodes
    Zhu, Liande
    Zhai, Jiangli
    Guo, Yingna
    Tian, Chunyuan
    Yang, Ruilan
    ELECTROANALYSIS, 2006, 18 (18) : 1842 - 1846
  • [33] Label-free amperometric immunobiosensor based on a gold colloid and Prussian blue nanocomposite film modified carbon ionic liquid electrode
    Ke-Jing Huang
    De-Jun Niu
    Jun-Yong Sun
    Xiao-Li Zhu
    Jun-Jie Zhu
    Analytical and Bioanalytical Chemistry, 2010, 397 : 3553 - 3561
  • [34] An amperometric sensor based on Prussian blue and poly(o-phenylenediamine) modified glassy carbon electrode for the determination of hydrogen peroxide in beverages
    Ping, Jianfeng
    Wu, Jian
    Fan, Kai
    Ying, Yibin
    FOOD CHEMISTRY, 2011, 126 (04) : 2005 - 2009
  • [35] Amperometric detection of morphine at a Prussian blue-modified indium tin oxide electrode
    Ho, KC
    Chen, CY
    Hsu, HC
    Chen, LC
    Shiesh, SC
    Lin, XZ
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (01) : 3 - 8
  • [36] Development of an amperometric biosensor based on glucose oxidase immobilized through silica sol-gel film onto Prussian Blue modified electrode
    Li, T
    Yao, ZH
    Ding, L
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (1-2) : 155 - 160
  • [37] Prussian Blue Modified Carbon Ionic Liquid Electrode: Electrochemical Characterization and Its Application for Hydrogen Peroxide and Glucose Measurements
    Haghighi, Behzad
    Nikzad, Ramin
    ELECTROANALYSIS, 2009, 21 (16) : 1862 - 1868
  • [38] Rhodium-Prussian Blue modified carbon paste electrode (Rh-PBMCPE) for amperometric detection of hydrogen peroxide
    Ivama, VM
    Serrano, SHP
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (04) : 551 - 555
  • [39] Nonenzymatic hydrogen peroxide sensor based on a Prussian Blue-modified carbon ionic liquid electrode
    Li, Yonghong
    Liu, Xiaoying
    Zeng, Xiandong
    Liu, Yong
    Liu, Xinsheng
    Wei, Wanzhi
    Luo, Shenglian
    MICROCHIMICA ACTA, 2009, 165 (3-4) : 393 - 398
  • [40] An amperometric biosensor for glucose based on self-assembling nanoparticles and electrosynthesis of poly-o-diaminobenzene on the Prussian blue-modified gold electrode
    Zhong, X
    Yuan, R
    Chai, YQ
    Dai, JY
    Liu, Y
    Tang, DP
    ANALYTICAL LETTERS, 2005, 38 (07) : 1085 - 1097