Amperometric glucose microbiosensor based on a Prussian Blue modified carbon fiber electrode for physiological applications

被引:24
|
作者
Salazar, P. [1 ]
O'Neill, R. D. [2 ]
Martin, M. [1 ]
Roche, R. [1 ]
Gonzalez-Mora, J. L. [1 ]
机构
[1] Univ La Laguna, Fac Med, Neurochem & Neuroimaging Grp, Tenerife, Spain
[2] Univ Coll Dublin, UCD Sch Chem & Chem Biol, Dublin 4, Ireland
关键词
Biosensor; Carbon fiber electrode; Brain glucose; Prussian blue; Polyphenylenediamine; ENZYME COMPOSITE BIOSENSOR; FLOW-INJECTION ANALYSIS; OXYGEN DEPENDENCE; IN-VIVO; BRAIN GLUCOSE; SENSITIVITY; DEHYDROGENASE; INTERFERENCE; GLUTAMATE; COATINGS;
D O I
10.1016/j.snb.2010.11.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Results of experiments in vitro and in vivo, using an amperometric glucose microbiosensor based on a Prussian Blue (PB) modified carbon fiber electrode with very low dimensions (similar to 10 mu m diameter), are presented. The electrocatalytic properties of the PB film enable detection of an enzymatic by-product (H2O2) at a very low applied potential: 0.0 V against SCE. The main steps during glucose microbiosensor construction were examined by cyclic voltammetry and electrochemical impedance spectroscopy. Excellent selectivity of the glucose microbiosensors against a large number of physiological interference compounds is demonstrated. Finally, microbiosensor responses during intraperitoneal injection, local infusion and local electrical stimulation showed sufficient sensitivity and stability to monitor multiphasic and reversible changes in brain ECF glucose levels during physiological experiments, illustrating the excellent properties and utility of this biosensor design in the neurosciences. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [21] Label-free amperometric immunobiosensor based on a gold colloid and Prussian blue nanocomposite film modified carbon ionic liquid electrode
    Huang, Ke-Jing
    Niu, De-Jun
    Sun, Jun-Yong
    Zhu, Xiao-Li
    Zhu, Jun-Jie
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (08) : 3553 - 3561
  • [22] Prussian Blue Modified Amperometric Hg2+ Ion Biosensor Based on Glucose Oxidase Inhibition
    Virbickas, Povilas
    Ziziunaite, Gerda
    Ramanavicius, Arunas
    Valiuniene, Ausra
    ELECTROANALYSIS, 2023, 35 (04)
  • [23] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    BIOELECTROCHEMISTRY, 2021, 138
  • [24] A Simple and Sensitive Method for the Amperometric Detection of Trace Chromium(VI) Based on Prussian Blue Modified Glassy Carbon Electrode
    Xing, Sujie
    Xu, He
    Shi, Guoyue
    Chen, Junshui
    Zeng, Liping
    Jin, Litong
    ELECTROANALYSIS, 2009, 21 (15) : 1678 - 1684
  • [25] Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
    E. Suprun
    G. Evtugyn
    H. Budnikov
    F. Ricci
    D. Moscone
    G. Palleschi
    Analytical and Bioanalytical Chemistry, 2005, 383 : 597 - 604
  • [26] Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
    Suprun, E
    Evtugyn, G
    Budnikov, H
    Ricci, F
    Moscone, D
    Palleschi, G
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (04) : 597 - 604
  • [27] Flow injection amperometric determination of pyridoxine at a Prussian blue nanoparticle-modified carbon ceramic electrode
    Razmi, H.
    Mohammad-Rezaei, R.
    ELECTROCHIMICA ACTA, 2010, 55 (05) : 1814 - 1819
  • [28] A HIGH-SENSITIVE GLUCOSE AMPEROMETRIC BIOSENSOR BASED ON PRUSSIAN-BLUE MODIFIED ELECTRODES
    KARYAKIN, AA
    GITELMACHER, OV
    KARYAKINA, EE
    ANALYTICAL LETTERS, 1994, 27 (15) : 2861 - 2869
  • [29] Prussian blue-modified nanoporous gold film electrode for amperometric determination of hydrogen peroxide
    Ghaderi, Seyran
    Mehrgardi, Masoud Ayatollahi
    BIOELECTROCHEMISTRY, 2014, 98 : 64 - 69
  • [30] Amperometric detection of hydrogen peroxide at a Prussian Blue-modified FTO electrode
    Tseng, KS
    Chen, LC
    Ho, KC
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 738 - 745