High-Yield Passive Plasma Filtration from Human Finger Prick Blood

被引:48
作者
Hauser, Janosch [1 ]
Lenk, Gabriel [1 ]
Hansson, Jonas [1 ]
Beck, Olof [2 ]
Stemme, Goran [1 ]
Roxhed, Niclas [1 ]
机构
[1] KTH Royal Inst Technol, Dept Micro & Nanosyst, S-10044 Stockholm, Sweden
[2] Karolinska Inst, Dept Lab Med, S-14186 Stockholm, Sweden
基金
欧洲研究理事会;
关键词
SEPARATION; EXTRACTION; DEVICE;
D O I
10.1021/acs.analchem.8b03175
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Whole-blood microsampling provides many benefits such as remote, patient-centric, and minimally invasive sampling. However, blood plasma, and not whole blood, is the prevailing matrix in clinical laboratory investigations. The challenge with plasma microsampling is to extract plasma volumes large enough to reliably detect low-concentration analytes from a small finger prick sample. Here we introduce a passive plasma filtration device that provides a high extraction yield of 65%, filtering 18 mu L of plasma from 50 mu L of undiluted human whole blood (hematocrit 45%) within less than 10 min. The enabling design element is a wedge-shaped connection between the blood filter and the hydrophilic bottom surface of a capillary channel. Using finger prick and venous blood samples from more than 10 healthy volunteers, we examined the filtration kinetics of the device over a hematocrit range of 35-55% and showed that 73 +/- 8% of the total protein content was successfully recovered after filtration. The presented plasma filtration device tackles a major challenge toward patient-centric blood microsampling by providing high-yield plasma filtration, potentially allowing reliable detection of low-concentration analytes from a blood microsample.
引用
收藏
页码:13393 / 13399
页数:7
相关论文
共 28 条
[1]  
Adiga U., 2016, J. Biotechnol. Biochem, V2, P49
[2]  
Busher J. T, 1990, CLIN METHODS HIST PH, V3
[3]   Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications [J].
Crowley, TA ;
Pizziconi, V .
LAB ON A CHIP, 2005, 5 (09) :922-929
[4]  
Davis RH., 1992, membrane handbook, P461, DOI [10.1007/978-1-4615-3548-5_32, DOI 10.1007/978-1-4615-3548-5_32]
[5]  
Dimov IK, 2011, LAB CHIP, V11, P845, DOI [10.1039/c0lc00403k, 10.1039/c01c00403k]
[6]   Pharmacokinetic considerations as to when to use dried blood spot sampling [J].
Emmons, Gary ;
Rowland, Malcom .
BIOANALYSIS, 2010, 2 (11) :1791-1796
[7]   Use of Dried Plasma Spots for the Quantification of Iothalamate in Clinical Studies [J].
Hagan, Andrew S. ;
Jones, David R. ;
Agarwal, Rajiv .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2013, 8 (06) :909-914
[8]   Development and validation of a low cost blood filtration element separating plasma from undiluted whole blood [J].
Homsy, Alexandra ;
van der Wal, Peter D. ;
Doll, Werner ;
Schaller, Roland ;
Korsatko, Stefan ;
Ratzer, Maria ;
Ellmerer, Martin ;
Pieber, Thomas R. ;
Nicol, Andreas ;
De Rooij, Nico F. .
BIOMICROFLUIDICS, 2012, 6 (01)
[9]   Micro-scale blood plasma separation: from acoustophoresis to egg-beaters [J].
Kersaudy-Kerhoas, Maiwenn ;
Sollier, Elodie .
LAB ON A CHIP, 2013, 13 (17) :3323-3346
[10]   Simple, Miniaturized Blood Plasma Extraction Method [J].
Kim, Jin-Hee ;
Woenker, Timothy ;
Adamec, Jiri ;
Regnier, Fred E. .
ANALYTICAL CHEMISTRY, 2013, 85 (23) :11501-11508