Electrochemical determination of homocysteine at a gold nanoparticle-modified electrode

被引:71
|
作者
Agui, L. [1 ]
Pena-Farfal, C. [1 ]
Yanez-Sedeno, P. [1 ]
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
gold nanoparticle-modified electrode; homocysteine; HPLC with amperometric detection;
D O I
10.1016/j.talanta.2007.05.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of a colloidal gold-cysteamine-carbon paste electrode, Au-coll-Cyst-CPE, for the electrochemical determination of homocysteine is reported. The improved voltammetric behaviour of homocysteine at Au-coll-Cyst-CPE with respect to that observed at a gold disk electrode is attributed to an enhanced electron transfer kinetics as a consequence of the array distribution of gold nanoparticles immobilized onto the Cyst SAM. Cyclic voltammtery of homocysteine showed an adsorption-controlled current for scan rates between 500 and 5000mVs(-1). The hydrodynamic voltammogram constructed for homocysteine allowed the selection of a potential value of +600 mV, where the background current is negligible, for the amperometric detection of the analyte at the Au-coll -Cyst-CPE. Using a flow rate of 0.8 ml min(-1), the R. S.D. value for i(p) after 25 repetitive P injections of homocysteine was of 4.3%, and one single electrode could be used for more than 15 days without any treatment or regeneration procedure of the modified electrode surface. An HPLC method for the separation and quantification of homocysteine and related thiols, using amperometric detection at the modified electrode has been developed. A mobile phase consisting of 2:98% (v/v) acetonitrile:0.05 mol l(-1) buffer solution of pH 2.0, and a detection potential of +0.80 V were selected. Separation with baseline. resolution and retention times of 3.00, 3.60, 4.52, 5.71 and 7.79 min were obtained for cysteine, homocysteine, glutathion, penicillamine and N-acetyl-cysteine, respectively. Calibration graphs were constructed for all the separated compounds. Detection limits ranged between 20 nM for cysteine and 120 nM for penilcillamine, with a value for homocysteine of 30 nM. These values compare advantageously with those achieved with previously reported HPLC methods using electrochemical, UV, fluorescence and MS detection modes. The developed method was applied to the determination of cysteine and homocysteine serum samples with good results. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:412 / 420
页数:9
相关论文
共 50 条
  • [41] Electrochemical Detection of Cardiac Biomarker Troponin I at Gold Nanoparticle-Modified ITO Electrode by Using Open Circuit Potential
    Ahammad, A. J. Saleh
    Choi, Yo-Han
    Koh, Kwangnak
    Kim, Jae-Ho
    Lee, Jae-Joon
    Lee, Minsu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (06): : 1906 - 1916
  • [42] Gold nanoparticle-modified glassy carbon electrode for electrochemical investigation of aliphatic di-carboxylic acids in aqueous media
    El-Cheick, F. M.
    Rashwan, F. A.
    Mahmoud, H. A.
    El-Rouby, Mahmoud
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (08) : 1425 - 1443
  • [43] Silver nanoparticle-modified electrode for the determination of nitro compound-containing pesticides
    Camila Alves de Lima
    Edson Roberto Santana
    Jamille Valéria Piovesan
    Almir Spinelli
    Analytical and Bioanalytical Chemistry, 2016, 408 : 2595 - 2606
  • [44] Development of the Research on Gold Nanoparticle-modified Electrodes
    Oyama, Munetaka
    BUNSEKI KAGAKU, 2014, 63 (09) : 707 - 713
  • [45] Determination of cyclic GMP concentration using a gold nanoparticle-modified optical fiber
    Huang, Kuang-Tse
    Lin, Tsao-Jen
    Hsu, Ming-Hsiung
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (01): : 11 - 15
  • [46] An impedimetric aptasensor for Shigella dysenteriae using a gold nanoparticle-modified glassy carbon electrode
    Zarei, Seyed Sanaan
    Soleimanian-Zad, Sabihe
    Ensafi, Ali A.
    MICROCHIMICA ACTA, 2018, 185 (12)
  • [47] Gold nanoparticle-modified graphite pencil electrode for the high-sensitivity detection of hydrazine
    Aziz, Md Abdul
    Kawde, Abdel-Nasser
    TALANTA, 2013, 115 : 214 - 221
  • [48] An impedimetric aptasensor for Shigella dysenteriae using a gold nanoparticle-modified glassy carbon electrode
    Seyed Sanaan Zarei
    Sabihe Soleimanian-Zad
    Ali A. Ensafi
    Microchimica Acta, 2018, 185
  • [49] Silver nanoparticle-modified electrode for the determination of nitro compound-containing pesticides
    de Lima, Camila Alves
    Santana, Edson Roberto
    Piovesan, Jamille Valeria
    Spinelli, Almir
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (10) : 2595 - 2606
  • [50] Sol-Gel/Chitosan/Gold Nanoparticle-Modified Electrode in Mediated Bacterial Biosensor
    Habib, Omer
    Demirkol, Dilek Odaci
    Timur, Suna
    FOOD ANALYTICAL METHODS, 2012, 5 (02) : 188 - 194