Electrochemical determination of homocysteine at a gold nanoparticle-modified electrode

被引:71
|
作者
Agui, L. [1 ]
Pena-Farfal, C. [1 ]
Yanez-Sedeno, P. [1 ]
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
gold nanoparticle-modified electrode; homocysteine; HPLC with amperometric detection;
D O I
10.1016/j.talanta.2007.05.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of a colloidal gold-cysteamine-carbon paste electrode, Au-coll-Cyst-CPE, for the electrochemical determination of homocysteine is reported. The improved voltammetric behaviour of homocysteine at Au-coll-Cyst-CPE with respect to that observed at a gold disk electrode is attributed to an enhanced electron transfer kinetics as a consequence of the array distribution of gold nanoparticles immobilized onto the Cyst SAM. Cyclic voltammtery of homocysteine showed an adsorption-controlled current for scan rates between 500 and 5000mVs(-1). The hydrodynamic voltammogram constructed for homocysteine allowed the selection of a potential value of +600 mV, where the background current is negligible, for the amperometric detection of the analyte at the Au-coll -Cyst-CPE. Using a flow rate of 0.8 ml min(-1), the R. S.D. value for i(p) after 25 repetitive P injections of homocysteine was of 4.3%, and one single electrode could be used for more than 15 days without any treatment or regeneration procedure of the modified electrode surface. An HPLC method for the separation and quantification of homocysteine and related thiols, using amperometric detection at the modified electrode has been developed. A mobile phase consisting of 2:98% (v/v) acetonitrile:0.05 mol l(-1) buffer solution of pH 2.0, and a detection potential of +0.80 V were selected. Separation with baseline. resolution and retention times of 3.00, 3.60, 4.52, 5.71 and 7.79 min were obtained for cysteine, homocysteine, glutathion, penicillamine and N-acetyl-cysteine, respectively. Calibration graphs were constructed for all the separated compounds. Detection limits ranged between 20 nM for cysteine and 120 nM for penilcillamine, with a value for homocysteine of 30 nM. These values compare advantageously with those achieved with previously reported HPLC methods using electrochemical, UV, fluorescence and MS detection modes. The developed method was applied to the determination of cysteine and homocysteine serum samples with good results. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:412 / 420
页数:9
相关论文
共 50 条
  • [31] A gold nanoparticle chemically modified gold electrode for the determination of surfactants
    Merli, Daniele
    Ferrari, Chiara
    Cabrini, Elisa
    Dacarro, Giacomo
    Pallavicini, Piersandro
    Profumo, Antonella
    RSC ADVANCES, 2016, 6 (108) : 106500 - 106507
  • [32] Electrochemical Detection of Metronidazole Using Silver Nanoparticle-Modified Carbon Paste Electrode
    Zoubir, Jallal
    Bougdour, Nadia
    El Hayaoui, Widad
    Radaa, Chaimae
    Idlahcen, Abderrahim
    Assabbane, Ali
    Bakas, Idriss
    ELECTROCATALYSIS, 2022, 13 (04) : 386 - 401
  • [33] Electrochemical Detection of Metronidazole Using Silver Nanoparticle-Modified Carbon Paste Electrode
    Jallal Zoubir
    Nadia Bougdour
    Widad El Hayaoui
    Chaimae Radaa
    Abderrahim Idlahcen
    Ali Assabbane
    Idriss Bakas
    Electrocatalysis, 2022, 13 : 386 - 401
  • [34] Determination of vanillin by using gold nanoparticle-modified screen-printed carbon electrode modified with graphene quantum dots and Nafion
    Duran, Gema M.
    Llorent-Martinez, Eulogio J.
    Contento, Ana M.
    Rios, Angel
    MICROCHIMICA ACTA, 2018, 185 (03)
  • [35] Nickel nanoparticle-modified electrode for ultra-sensitive electrochemical detection of insulin
    Yu, Yanan
    Guo, Meisong
    Yuan, Mengwei
    Liu, Weitong
    Hu, Jingbo
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 215 - 219
  • [36] Electrochemical detection of bisphenol A at graphene/melamine nanoparticle-modified glassy carbon electrode
    Rongyan Shen
    Weiming Zhang
    Yuan Yuan
    Guangyu He
    Haiqun Chen
    Journal of Applied Electrochemistry, 2015, 45 : 343 - 352
  • [37] Determination of vanillin by using gold nanoparticle-modified screen-printed carbon electrode modified with graphene quantum dots and Nafion
    Gema M. Durán
    Eulogio J. Llorent-Martínez
    Ana M. Contento
    Ángel Ríos
    Microchimica Acta, 2018, 185
  • [38] Sensitive Flow-Injection Electrochemical Determination of Hydrogen Peroxide at a Palladium Nanoparticle-Modified Pencil Graphite Electrode
    Karakaya, Serkan
    Dilgin, Yusuf
    ANALYTICAL LETTERS, 2019, 52 (06) : 998 - 1017
  • [39] Electrochemical Detection of Mercaptans in Wine Using Gold Nanoparticle-Modified Carbon Electrodes
    Alonso-Lomillo, M. Asuncion
    Lopez-Gil, Sheila
    Javier del Campo Garcia, F.
    Dominguez-Renedo, Olga
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (08)
  • [40] Gold nanoparticle-modified glassy carbon electrode for electrochemical investigation of aliphatic di-carboxylic acids in aqueous media
    F. M. El-Cheick
    F. A. Rashwan
    H. A. Mahmoud
    Mahmoud El-Rouby
    Journal of Solid State Electrochemistry, 2010, 14 : 1425 - 1443