Electrochemical determination of homocysteine at a gold nanoparticle-modified electrode

被引:71
|
作者
Agui, L. [1 ]
Pena-Farfal, C. [1 ]
Yanez-Sedeno, P. [1 ]
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
gold nanoparticle-modified electrode; homocysteine; HPLC with amperometric detection;
D O I
10.1016/j.talanta.2007.05.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of a colloidal gold-cysteamine-carbon paste electrode, Au-coll-Cyst-CPE, for the electrochemical determination of homocysteine is reported. The improved voltammetric behaviour of homocysteine at Au-coll-Cyst-CPE with respect to that observed at a gold disk electrode is attributed to an enhanced electron transfer kinetics as a consequence of the array distribution of gold nanoparticles immobilized onto the Cyst SAM. Cyclic voltammtery of homocysteine showed an adsorption-controlled current for scan rates between 500 and 5000mVs(-1). The hydrodynamic voltammogram constructed for homocysteine allowed the selection of a potential value of +600 mV, where the background current is negligible, for the amperometric detection of the analyte at the Au-coll -Cyst-CPE. Using a flow rate of 0.8 ml min(-1), the R. S.D. value for i(p) after 25 repetitive P injections of homocysteine was of 4.3%, and one single electrode could be used for more than 15 days without any treatment or regeneration procedure of the modified electrode surface. An HPLC method for the separation and quantification of homocysteine and related thiols, using amperometric detection at the modified electrode has been developed. A mobile phase consisting of 2:98% (v/v) acetonitrile:0.05 mol l(-1) buffer solution of pH 2.0, and a detection potential of +0.80 V were selected. Separation with baseline. resolution and retention times of 3.00, 3.60, 4.52, 5.71 and 7.79 min were obtained for cysteine, homocysteine, glutathion, penicillamine and N-acetyl-cysteine, respectively. Calibration graphs were constructed for all the separated compounds. Detection limits ranged between 20 nM for cysteine and 120 nM for penilcillamine, with a value for homocysteine of 30 nM. These values compare advantageously with those achieved with previously reported HPLC methods using electrochemical, UV, fluorescence and MS detection modes. The developed method was applied to the determination of cysteine and homocysteine serum samples with good results. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:412 / 420
页数:9
相关论文
共 50 条
  • [21] Electrochemical Characterization of an Oleyl-coated Magnetite Nanoparticle-Modified Electrode
    Murugappan, Krishnan
    Silvester, Debbie S.
    Chaudhary, Deeptangshu
    Arrigan, Damien W. M.
    CHEMELECTROCHEM, 2014, 1 (07): : 1211 - 1218
  • [22] Electrochemical detection of plant virus using gold nanoparticle-modified electrodes
    Khater, Mohga
    de la Escosura-Muniz, Alfredo
    Quesada-Gonzalez, Daniel
    Merkoci, Arben
    ANALYTICA CHIMICA ACTA, 2019, 1046 : 123 - 131
  • [23] Electrochemical Investigation of Calcium Dobesilate and Interactions with Bovine Serum Albumin on Gold Nanoparticle-Modified Glassy Carbon Electrode
    Xu, Hui
    Li, Xiaohong
    Zhang, Jingwei
    Zhang, Zhijun
    Liu, Kuaizhi
    ANALYTICAL LETTERS, 2009, 42 (08) : 1094 - 1110
  • [24] Determination of rutin using a CeO2 nanoparticle-modified electrode
    Yan Wei
    Guangfeng Wang
    Maoguo Li
    Cong Wang
    Bin Fang
    Microchimica Acta, 2007, 158 : 269 - 274
  • [25] Determination of rutin using a CeO2 nanoparticle-modified electrode
    Wei, Yan
    Wang, Guangfeng
    Li, Maoguo
    Wang, Cong
    Fang, Bin
    MICROCHIMICA ACTA, 2007, 158 (3-4) : 269 - 274
  • [26] Electrocatalytic Oxidation of Tryptophan at Gold Nanoparticle-Modified Carbon Ionic Liquid Electrode
    Safavi, A.
    Momeni, S.
    ELECTROANALYSIS, 2010, 22 (23) : 2848 - 2855
  • [27] Sol–Gel/Chitosan/Gold Nanoparticle-Modified Electrode in Mediated Bacterial Biosensor
    Omer Habib
    Dilek Odaci Demirkol
    Suna Timur
    Food Analytical Methods, 2012, 5 : 188 - 194
  • [28] Highly Sensitive Detection of Amoxicillin Based on Gold Nanoparticle-Modified ITO Electrode
    Chowdhury, Taslima R.
    Shaikh, A. A.
    Akter, Humaiara
    Neaz, M. M.
    Bakshi, P. K.
    Ahammad, A. J. Saleh
    ECS SOLID STATE LETTERS, 2014, 3 (02) : P14 - P16
  • [29] Selective detection of neurotransmitter serotonin by a gold nanoparticle-modified glassy carbon electrode
    Wei, Xiaohan
    Wang, Fei
    Yin, Yumin
    Liu, Qiongyan
    Zou, Lina
    Ye, Baoxian
    ANALYST, 2010, 135 (09) : 2286 - 2290
  • [30] Electrochemical detection of bisphenol A at graphene/melamine nanoparticle-modified glassy carbon electrode
    Shen, Rongyan
    Zhang, Weiming
    Yuan, Yuan
    He, Guangyu
    Chen, Haiqun