Determination of tetramethylthiuram disulfide on an interdigitated microelectrode array

被引:14
|
作者
Tomcík, P [1 ]
Krajcíková, M [1 ]
Bustin, D [1 ]
Skacáni, I [1 ]
机构
[1] Slovak Univ Technol Bratislava, Dept Analyt Chem, SK-81237 Bratislava, Slovakia
关键词
tetramethylthiuram disulfide; interdigitated microelectrode array; electrogenerated agent;
D O I
10.1016/S1388-2481(01)00131-X
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel analytical technique for the determination of tetramethylthiuram disulfide (TMTD) was developed. It is based on total oxidation of TMTD with hypobromite. Hypobromite is generated on one segment of interdigitated array. It reacts rapidly and quantitatively with TMTD and unreacted flux of hypobromite is detected on second segment of the interdigitated microelectrode array ODA). Detection is amperometric therefore the potential of the second (detector) segment is fixed at the value corresponding to the limiting current of the opposite reaction to that taking place on the generator segment. Rather low detection limit of this method (7 x 10(-7) mol dm(-3)) allows the analysis of samples with trace content of TMTD. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 194
页数:4
相关论文
共 50 条
  • [1] Voltammetric determination of iodide by use of an interdigitated microelectrode array
    Peter Tomčík
    Dušan Bustin
    Fresenius' Journal of Analytical Chemistry, 2001, 371 : 562 - 564
  • [2] Voltammetric determination of iodide by use of an interdigitated microelectrode array
    Tomcík, P
    Bustin, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04): : 562 - 564
  • [3] Glucose Sensing Based on Interdigitated Array Microelectrode
    Peng Jin
    Akira Yamaguchi
    Fumika Asarioi
    Shigeki Matsuo
    Jiubin Tan
    Hiroaki Misawa
    Analytical Sciences, 2001, 17 : 841 - 846
  • [4] Glucose sensing based on interdigitated array microelectrode
    Jin, P
    Yamaguchi, A
    Oi, FA
    Matsuo, S
    Tan, JB
    Misawa, H
    ANALYTICAL SCIENCES, 2001, 17 (07) : 841 - 846
  • [5] Determination of pharmaceutical dosage forms via diffusion layer titration at an interdigitated microelectrode array
    Tomcík, P
    Krajcíková, M
    Bustin, D
    TALANTA, 2001, 55 (06) : 1065 - 1070
  • [6] Calibrationless determination of electroactive species using chronoamperograms at collector segment of interdigitated microelectrode array
    P. Jenčušová
    P. Tomčík
    D. Bustin
    M. Rievaj
    Z. Dovalovská
    Chemical Papers, 2006, 60 : 173 - 178
  • [7] Calibrationless determination of electroactive species using chronoamperograms at collector segment of interdigitated microelectrode array
    Jencusova, P.
    Tomcik, P.
    Bustin, D.
    Rievaj, M.
    Dovalovska, Z.
    CHEMICAL PAPERS, 2006, 60 (03) : 173 - 178
  • [8] EXTRACTION AND PHOTOMETRIC DETERMINATION OF PALLADIUM(II) WITH TETRAMETHYLTHIURAM DISULFIDE
    UTTARWAR, RM
    JOSHI, AP
    CHEMIA ANALITYCZNA, 1978, 23 (05): : 719 - 726
  • [9] Calibrationless determination of potassium hexacyanoferrate(II) and hexaammineruthenium(III) chloride at the interdigitated microelectrode array (IDA)
    Tomcik, P
    Skalicanová, A
    Bustin, D
    Rievaj, M
    CHEMIA ANALITYCZNA, 2004, 49 (01): : 41 - 49
  • [10] COMPLEXOMETRIC DETERMINATION OF TETRAMETHYLTHIURAM DISULFIDE IN THIURAM-D
    STRIGINA, VI
    GUDKOVA, AE
    INDUSTRIAL LABORATORY, 1980, 46 (07): : 652 - 653