Less invasive hemodynamic monitoring in critically ill patients

被引:206
作者
Teboul, Jean-Louis [1 ]
Saugel, Bernd [2 ]
Cecconi, Maurizio [3 ]
De Backer, Daniel [4 ]
Hofer, Christoph K. [5 ]
Monnet, Xavier [1 ]
Perel, Azriel [6 ]
Pinsky, Michael R. [7 ]
Reuter, Daniel A. [2 ]
Rhodes, Andrew [3 ]
Squara, Pierre [8 ]
Vincent, Jean-Louis [9 ]
Scheeren, Thomas W. [10 ]
机构
[1] Hop Univ Paris Sud, Hop Bicetre, AP HP, Serv Reanimat Med, 78 Rue Gen Leclerc, F-94270 Le Kremlin Bicetre, France
[2] Univ Med Ctr Hamburg Eppendorf, Dept Anesthesiol, Ctr Anesthesiol & Intens Care Med, D-20246 Hamburg, Germany
[3] St Georges Hosp & Med Sch, Anaesthesia & Intens Care, London, England
[4] Univ Libre Bruxelles, CHIREC Hosp, Dept Intens Care, Brussels, Belgium
[5] Triemli City Hosp, Inst Anesthesiol & Intens Care Med, Dept Transversal Med, Zurich, Switzerland
[6] Tel Aviv Univ, Dept Anesthesiol & Intens Care, Sheba Med Ctr, Tel Aviv, Israel
[7] Univ Pittsburgh, Dept Crit Care Med, Pittsburgh, PA 15261 USA
[8] Clin Ambroise Pare, F-92200 Neuilly Sur Seine, France
[9] Univ Libre Bruxelles, Erasme Univ Hosp, Dept Intens Care, Brussels, Belgium
[10] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, Groningen, Netherlands
关键词
Hemodynamic monitoring; Pulse contour analysis; Transpulmonary thermodilution; Pulse pressure variation; Esophageal Doppler; Bioreactance; CARDIAC-OUTPUT MEASUREMENTS; PLETH VARIABILITY INDEX; PREDICT FLUID RESPONSIVENESS; CENTRAL VENOUS-PRESSURE; ARTERY APPLANATION TONOMETRY; RIGHT-HEART CATHETERIZATION; EXTRAVASCULAR LUNG WATER; PULSE-CONTOUR ANALYSIS; PULMONARY-ARTERY; STROKE VOLUME;
D O I
10.1007/s00134-016-4375-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Over the last decade, the way to monitor hemodynamics at the bedside has evolved considerably in the intensive care unit as well as in the operating room. The most important evolution has been the declining use of the pulmonary artery catheter along with the growing use of echocardiography and of continuous, real-time, minimally or totally non-invasive hemodynamic monitoring techniques. This article, which is the result of an agreement between authors belonging to the Cardiovascular Dynamics Section of the European Society of Intensive Care Medicine, discusses the advantages and limits of using such techniques with an emphasis on their respective place in the hemodynamic management of critically ill patients with hemodynamic instability.
引用
收藏
页码:1350 / 1359
页数:10
相关论文
共 78 条
[1]   Accuracy of Noninvasive Estimated Continuous Cardiac Output (esCCO) Compared to Thermodilution Cardiac Output: A Pilot Study in Cardiac Patients [J].
Ball, Timothy R. ;
Tricinella, Anthony P. ;
Kimbrough, Alex ;
Luna, Sarah ;
Gloyna, David F. ;
Villamaria, Frank J. ;
Culp, William C., Jr. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) :1128-1132
[2]   Complications related to less-invasive haemodynamic monitoring [J].
Belda, F. J. ;
Aguilar, G. ;
Teboul, J. L. ;
Pestana, D. ;
Redondo, F. J. ;
Malbrain, M. ;
Luis, J. C. ;
Ramasco, F. ;
Umgelter, A. ;
Wendon, J. ;
Kirov, M. ;
Fernandez-Mondejar, E. .
BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (04) :482-486
[3]   The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials [J].
Benes, Jan ;
Giglio, Mariateresa ;
Brienza, Nicola ;
Michard, Frederic .
CRITICAL CARE, 2014, 18 (05) :1-11
[4]   Ability of esCCO to track changes in cardiac output [J].
Biais, M. ;
Berthezene, R. ;
Petit, L. ;
Cottenceau, V. ;
Sztark, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) :403-410
[5]   Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting [J].
Biais, Matthieu ;
Carrie, Cedric ;
Delaunay, Francois ;
Morel, Nicolas ;
Revel, Philippe ;
Janvier, Gerard .
CRITICAL CARE, 2012, 16 (03)
[6]   Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients [J].
Biais, Matthieu ;
Cottenceau, Vincent ;
Petit, Laurent ;
Masson, Francoise ;
Cochard, Jean-Francois ;
Sztark, Francois .
CRITICAL CARE, 2011, 15 (04)
[7]   A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery [J].
Broch, O. ;
Renner, J. ;
Gruenewald, M. ;
Meybohm, P. ;
Schoettler, J. ;
Caliebe, A. ;
Steinfath, M. ;
Malbrain, M. ;
Bein, B. .
ANAESTHESIA, 2012, 67 (04) :377-383
[8]   Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre [J].
Cannesson, M. ;
Desebbe, O. ;
Rosamel, P. ;
Delannoy, B. ;
Robin, J. ;
Bastien, O. ;
Lehot, J. -J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) :200-206
[9]   Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine [J].
Cecconi, Maurizio ;
De Backer, Daniel ;
Antonelli, Massimo ;
Beale, Richard ;
Bakker, Jan ;
Hofer, Christoph ;
Jaeschke, Roman ;
Mebazaa, Alexandre ;
Pinsky, Michael R. ;
Teboul, Jean Louis ;
Vincent, Jean Louis ;
Rhodes, Andrew .
INTENSIVE CARE MEDICINE, 2014, 40 (12) :1795-1815
[10]   Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler [J].
Chen, Guo ;
Meng, Lingzhong ;
Alexander, Brenton ;
Nam Phuong Tran ;
Kain, Zeev N. ;
Cannesson, Maxime .
JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (04) :275-283