Use of active-edge silicon detectors as X-ray beam monitors

被引:14
|
作者
Kenney, C. J.
Hasi, J.
Parker, Sherwood
Thompson, A. C.
Westbrook, E.
机构
[1] Univ Manchester, Manchester M13 9PL, Lancs, England
[2] Univ Hawaii, Honolulu, HI 96822 USA
[3] Mol Biol Consortium, Chicago, IL USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
active-edge X-ray detectors; synchrotron beam monitors; silicon radiation detectors;
D O I
10.1016/j.nima.2007.08.102
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon detectors have been developed which are active to within several microns of the physical edge of the detector. These active-edge devices can be placed near an intense X-ray beam to accurately measure the X-ray beam properties. In addition, they can be fabricated in a variety of geometries that will be useful for monitoring the intensity, profile, and position of synchrotron X-ray beams. One shape is a detector with a through hole surrounded by four active elements. The hole allows the intense X-ray beam to go through the center while the four elements can detect any change in the position or dispersion of the beam. Another shape is a rectangular 5 mm long x 0.5 mm wide device with a set of four elements that are 100 mu m wide. These devices could be mounted on the upstream side of the jaws of an x v collimating slit to measure the intensity profile of the beam that each jaw of the slit is stopping. Small detectors could also be mounted in a cylindrical beam stop to give on-line beam intensity measurements. A variety of different geometries were tested at beamline 10.3.1 of the Advanced Light Source using a 12.5 keV X-ray beam. They have wide dynamic range, excellent position sensitivity and low sensitivity to radiation damage. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:178 / 181
页数:4
相关论文
共 50 条
  • [31] Special X-ray Silicon Detectors for Medical Applications
    Halmagean, E.
    Wagner, D.
    Tsoi, E.
    Misiakos, K.
    Acta Physica Polonica A, 91 (04):
  • [32] Improved X-ray silicon detectors for medical applications
    Halmagean, E
    Tsoi, E
    Misiakos, K
    Ohanisian, M
    Veron, A
    Cimpoca, V
    Lazarovici, D
    CAS '96 PROCEEDINGS - 1996 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 19TH EDITION, VOLS 1 AND 2, 1996, : 653 - 656
  • [33] Special X-ray silicon detectors for medical applications
    Halmagean, E
    Wagner, D
    Tsoi, E
    Misiakos, K
    Ohanisian, M
    Veron, A
    Cimpoca, V
    Lazarovici, D
    ACTA PHYSICA POLONICA A, 1997, 91 (04) : 789 - 792
  • [34] SILICON SURFACE BARRIER DETECTORS FOR X-RAY SPECTROSCOPY
    KALBITZER, S
    MELZER, W
    STUMPFI, W
    ZEITSCHRIFT FUR ANGEWANDTE PHYSIK, 1968, 24 (04): : 181 - +
  • [35] Silicon carbide X-ray detectors for planetary exploration
    Lees, J. E.
    Bassford, D. J.
    Bunce, E. J.
    Sims, M. R.
    Horsfall, A. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 174 - 176
  • [36] Evaluation of junction termination for silicon X-ray detectors
    Norlin, P.
    Xu, C.
    Perttu, D.
    Lundqvist, M.
    Aslund, M.
    Bakowski, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S68 - S71
  • [37] X-RAY RADIATION DAMAGE IN SILICON STRIP DETECTORS
    Wiacek, Piotr
    Dabrowski, Wladyslaw
    ACTA PHYSICA POLONICA B, 2016, 47 (02): : 279 - 285
  • [38] Probing active-edge silicon sensors using a high precision telescope
    Akiba, K.
    Artuso, M.
    van Beveren, V.
    van Beuzekom, M.
    Boterenbrood, H.
    Buytaert, J.
    Collins, P.
    Dumps, R.
    van der Heijden, B.
    Hombach, C.
    Hynds, D.
    Hsu, D.
    John, M.
    Koffeman, E.
    Leflat, A.
    Li, Y.
    Longstaff, I.
    Morton, A.
    Perez Trigo, E.
    Plackett, R.
    Reid, M. M.
    Perez, P. Rodriguez
    Schindler, H.
    Tsopelas, P.
    Vazquez Sierra, C.
    Wysokinski, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 777 : 110 - 117
  • [39] THE USE OF X-RAY FILMS IN BEAM DIRECTION FOR X-RAY THERAPY
    COPCUTT, WA
    BRITISH JOURNAL OF RADIOLOGY, 1949, 22 (256): : 210 - 214
  • [40] Beam-position monitors in the X-ray undulator beamline at PETRA
    Hahn, U
    Brefeld, W
    Hesse, M
    Schneider, JR
    Schulte-Schrepping, H
    Seebach, M
    Werner, M
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 627 - 629