Use of active-edge silicon detectors as X-ray beam monitors

被引:14
|
作者
Kenney, C. J.
Hasi, J.
Parker, Sherwood
Thompson, A. C.
Westbrook, E.
机构
[1] Univ Manchester, Manchester M13 9PL, Lancs, England
[2] Univ Hawaii, Honolulu, HI 96822 USA
[3] Mol Biol Consortium, Chicago, IL USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
active-edge X-ray detectors; synchrotron beam monitors; silicon radiation detectors;
D O I
10.1016/j.nima.2007.08.102
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon detectors have been developed which are active to within several microns of the physical edge of the detector. These active-edge devices can be placed near an intense X-ray beam to accurately measure the X-ray beam properties. In addition, they can be fabricated in a variety of geometries that will be useful for monitoring the intensity, profile, and position of synchrotron X-ray beams. One shape is a detector with a through hole surrounded by four active elements. The hole allows the intense X-ray beam to go through the center while the four elements can detect any change in the position or dispersion of the beam. Another shape is a rectangular 5 mm long x 0.5 mm wide device with a set of four elements that are 100 mu m wide. These devices could be mounted on the upstream side of the jaws of an x v collimating slit to measure the intensity profile of the beam that each jaw of the slit is stopping. Small detectors could also be mounted in a cylindrical beam stop to give on-line beam intensity measurements. A variety of different geometries were tested at beamline 10.3.1 of the Advanced Light Source using a 12.5 keV X-ray beam. They have wide dynamic range, excellent position sensitivity and low sensitivity to radiation damage. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:178 / 181
页数:4
相关论文
共 50 条
  • [1] Scintillator materials for x-ray detectors and beam monitors
    T. Martin
    A. Koch
    M. Nikl
    MRS Bulletin, 2017, 42 : 451 - 457
  • [2] Scintillator materials for x-ray detectors and beam monitors
    Martin, T.
    Koch, A.
    Nikl, M.
    MRS BULLETIN, 2017, 42 (06) : 451 - 456
  • [3] Active-Edge Planar Silicon Sensors for Large-Area Pixel Detectors
    Bosma, Marten
    Heijne, Erik
    Kalliopuska, Juha
    Visser, Jan
    Koffeman, Els
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1329 - 1333
  • [4] Silicon carbide X-ray beam position monitors for synchrotron applications
    Nida, Selamnesh
    Tsibizov, Alexander
    Ziemann, Thomas
    Woerle, Judith
    Moesch, Andy
    Schulze-Briese, Clemens
    Pradervand, Claude
    Tudisco, Salvatore
    Sigg, Hans
    Bunk, Oliver
    Grossner, Ulrike
    Camarda, Massimo
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 (01): : 28 - 35
  • [5] Edge-On Detectors with Active Edge for X-Ray Photon Counting Imaging
    Hansen, T. E.
    Ahmed, N.
    Ferber, A.
    Bouquet, G.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1341 - 1343
  • [6] Monolithic active-matrix silicon X-ray detectors
    Carini, Gabriella A.
    Chen, Wei
    Li, Zheng
    Rehak, Pavel
    Siddons, D. Peter
    Patel, Jyotica
    Steen, Steven E.
    Haensch, Wilfred
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C162 - C162
  • [7] Simulation of active-edge pixelated CdTe radiation detectors
    Duarte, D. D.
    Lipp, J. D.
    Schneider, A.
    Seller, P.
    Veale, M. C.
    Wilson, M. D.
    Baker, M. A.
    Sellin, P. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 139 - 145
  • [8] Silicon Detectors with a Differential Discriminatorfor Use in X-Ray Diffractometers
    Osadchii, S. M.
    Petukhov, A. A.
    Dunin, V. B.
    JOURNAL OF SURFACE INVESTIGATION, 2019, 13 (04): : 690 - 694
  • [9] Silicon Detectors with a Differential Discriminatorfor Use in X-Ray Diffractometers
    S. M. Osadchii
    A. A. Petukhov
    V. B. Dunin
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2019, 13 : 690 - 694
  • [10] X-ray irradiation of silicon detectors
    Chmill, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (02): : 722 - 726