Effects of Electric Field Distribution on Icing and Flashover Performance of 220 kV Composite Insulators

被引:27
作者
Hu, Qin [1 ]
Yuan, Wei [1 ]
Shu, Lichun [1 ]
Jiang, Xingliang [1 ]
Wang, Shijing [1 ]
机构
[1] Chongqing Univ, Sch Elect Engn, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
关键词
Composite insulator; energized icing; grading ring; electric field distribution; flashover voltage; ICE;
D O I
10.1109/TDEI.2014.002181
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The energized icing of composite insulators has been studied by the researchers around the world, but not much about the effects of electric field distribution on their icing and flashover performance. For this purpose, the ice accretion and flashover performance of 220 kV composite insulators with two shed configurations on occasions of different electric field distributions considering the effect of grading rings are analyzed in this paper. The test results indicate that the intensity and homogeneous distribution of electric field have positive effects on the appearance, density and weight of ice; the improvement of electric field distribution after installing grading ring has more effects than the icing characteristics, such as quality, density as well as appearance of ice, on flashover voltages of ice-covered composite insulators; the icing flashover voltages are increased by the improvement of electric field distribution and the increasing ranges of icing flashover voltage were relied on shed configuration. Icing accumulation patterns have less effect on flashover performance of composite insulators with alternate-diameter or widely spaced shed configurations.
引用
收藏
页码:2181 / 2189
页数:9
相关论文
共 32 条
[1]   Improving Electrical Performance of EHV Post Station Insulators under Severe Icing Conditions Using Modified Grading Rings [J].
Akkal, H. ;
Volat, C. ;
Farzaneh, M. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (01) :221-228
[2]  
Chen S., 2004, INSULATORS SURGE ARR, V11, P8
[3]   Forces acting on water droplets falling in oil under the influence of an electric field: numerical predictions versus experimental observations [J].
Chiesa, M ;
Melheim, JA ;
Pedersen, A ;
Ingebrigtsen, S ;
Berg, G .
EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2005, 24 (06) :717-732
[4]   Insulator leakage distance dimensioning in areas of winter contamination using cold-fog test results [J].
Chisholm, William A. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) :1455-1461
[5]   Insulator icing test methods and procedures a position paper prepared by the IEEE task force on insulator icing test methods [J].
Farzaneh, M ;
Baker, T ;
Bernstorf, A ;
Brown, K ;
Chisholm, WA ;
de Tourreil, C ;
Drapeau, JF ;
Fikke, S ;
George, JM ;
Gnandt, E ;
Grisham, T ;
Gutman, I ;
Hartings, R ;
Kremer, R ;
Powell, G ;
Rolfseng, L ;
Rozek, T ;
Ruff, DL ;
Shaffner, D ;
Sklenicka, V ;
Sundararajan, R ;
Yu, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (04) :1503-1515
[6]  
Farzaneh M., 2009, INSULATORS ICING POL, P363
[7]  
FARZANEH M, 2000, IEEE INT S EL INS AN, P349
[8]   LONG-RANGE TRANSPORTED POLLUTANTS AND CONDUCTIVITY OF ATMOSPHERIC ICE ON INSULATORS [J].
FIKKE, SM ;
HANSSEN, JE ;
ROLFSENG, L ;
GORUR, R ;
SCHNEIDER, HM ;
LAMPE, WD .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) :1311-1321
[9]   PERFORMANCE OF INSULATORS COVERED WITH SNOW OR ICE [J].
FUJIMURA, T ;
NAITO, K ;
HASEGAWA, Y .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (05) :1621-1631
[10]   Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000 WUHV AC transmission lines [J].
Hu, Jianlin ;
Sun, Caixin ;
Jiang, Xingliang ;
Zhang, Zhijin ;
Shu, Lichun .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) :1347-1356