Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control

被引:250
作者
El-Chami, Mikhael F. [1 ]
Al-Samadi, Faisal [2 ]
Clementy, Nicolas [3 ]
Garweg, Christophe [4 ]
Luis Martinez-Sande, Jose [5 ]
Piccini, Jonathan P. [6 ]
Iacopino, Saverio [7 ]
Lloyd, Michael [1 ]
Vinolas Prat, Xavier [8 ]
Jacobsen, Michael Dilou [9 ]
Ritter, Philippe [10 ]
Johansen, Jens Brock [11 ]
Tondo, Claudio [12 ]
Liu, Fang [13 ]
Fagan, Dedra H. [13 ]
Eakley, Alyssa K. [13 ]
Roberts, Paul R. [14 ]
机构
[1] Emory Univ, Div Cardiol, Sect Electrophysiol, Atlanta, GA 30322 USA
[2] King Fahad Med City, King Salman Heart Ctr, Riyadh, Saudi Arabia
[3] Hop Trousseau, Dept Med Cardiol, Ctr Hosp Reg Univ Tours, Tours, France
[4] Univ Ziekenhuizen Leuven, Dept Cardiovasc Sci, Campus Gasthuisberg, Leuven, Belgium
[5] Univ Clin Hosp Santiago de Compostela, Unidad Arritmias, Serv Cardiol, Santiago De Compostela, Spain
[6] Duke Univ, Med Ctr, Duke Ctr Atrial Fibrillat, Durham, NC USA
[7] Maria Cecelia Hosp, Electrophysiol Unit, Arrhythmol Dept, Cotignola, Italy
[8] Hosp Santa Creu & Sant Pau, Arrhythmia Unit, Barcelona, Spain
[9] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
[10] Univ Bordeaux, Hop Cardiol Haut Leveque, CHU Bordeaux, Bordeaux, France
[11] Odense Univ Hosp, Dept Cardiol, Odense, Denmark
[12] Univ Milan, Monzino Cardiac Ctr, IRCCS, Dept Clin Sci & Community, Milan, Italy
[13] Medtronic Plc, Mounds View, MN USA
[14] Univ Hosp Southampton NHS Fdn Trust, Southampton, Hants, England
关键词
Leadless pacing; Real-world performance; Transcatheter pacemaker; Updated results; Transvenous pacemaker; LEADLESS PACEMAKER; COMPLICATIONS; IMPLANTATION; PREDICTORS;
D O I
10.1016/j.hrthm.2018.08.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Early results of the Micra Investigational Device Exemption (IDE) study and Micra Post-Approval Registry (PAR) demonstrated excellent safety and efficacy performance; however, intermediate-term results across a large patient population in the real-world setting have not been evaluated. OBJECTIVES We report updated performance of the Micra transcatheter pacemaker from a worldwide PAR and compare it with the IDE study as well as a transvenous historical control. METHODS The safety objective of the analysis was system- or procedure-related major complications through 12 months postimplantation. We compared the major complication rate with that of the 726 patients from the IDE and with a reference data set of 2667 patients with transvenous pacemakers by using a Fine-Gray competing risk model. RESULTS The Micra device was successfully implanted in 1801 of 1817 patients (99.1%). The mean follow-up period was 6.8 +/- 6.9 months. Through 12 months, the major complication rate was 2.7% (95% confidence interval [CI] 2.0%-3.7%). The risk of major complications for Micra PAR patients was 63% lower than that for patients with transvenous pacemakers through 12 months postimplantation (hazard ratio 0.37; 95% CI 0.27-0.52; P < .001).The major complication rate trended lower in the PAR than in the IDE study (hazard ratio 0.71; 95% CI 0.44-1.1; P = .160), driven by the lower pericardial effusion rate in the PAR. There were 3 cases of infection associated with the procedure, but none required device removal and there were no battery or telemetry issues. Pacing thresholds were low and stable through 12 months postimplantation. CONCLUSION Performance of the Micra transcatheter pacemaker in international clinical practice remains consistent with previously reported data. Major complications were infrequent and occurred 63% less often compared to transvenous systems.
引用
收藏
页码:1800 / 1807
页数:8
相关论文
共 13 条
  • [1] Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing Study
    Duray, Gabor Z.
    Ritter, Philippe
    El-Chami, Mikhael
    Narasimhan, Calambur
    Omar, Razali
    Tolosana, Jose M.
    Zhang, Shu
    Soejima, Kyoko
    Steinwender, Clemens
    Rapallini, Leonardo
    Cicic, Aida
    Fagan, Dedra H.
    Liu, Shufeng
    Reynolds, Dwight
    [J]. HEART RHYTHM, 2017, 14 (05) : 702 - 709
  • [2] How to Implant a Leadless Pacemaker With a Tine-Based Fixation
    El-Chami, Mikhael F.
    Roberts, Paul R.
    Kypta, Alex
    Omdahl, Pamela
    Bonner, Matthew D.
    Kowal, Robert C.
    Duray, Gabor Z.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (12) : 1495 - 1501
  • [3] Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark
    Kirkfeldt, Rikke Esberg
    Johansen, Jens Brock
    Nohr, Ellen Aagaard
    Jorgensen, Ole Dan
    Nielsen, Jens Cosedis
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (18) : 1186 - 1194
  • [4] Complete encapsulation of a leadless cardiac pacemaker
    Kypta, Alexander
    Blessberger, Hermann
    Lichtenauer, Michael
    Steinwender, Clemens
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (01) : 94 - 94
  • [5] Transcatheter/leadless pacing
    Lloyd, Michael S.
    El-Chami, Michael F.
    Nilsson, Kent R., Jr.
    Cantillon, Daniel J.
    [J]. HEART RHYTHM, 2018, 15 (04) : 624 - 628
  • [6] Mont L., 2018, HEART RHYTHM, V18, pS119
  • [7] Long-term survival after permanent pacemaker implantation: analysis of predictors for increased mortality
    Pyatt, JR
    Somauroo, JD
    Jackson, M
    Grayson, AD
    Osula, S
    Aggarwal, RK
    Charles, RG
    Connelly, DT
    [J]. EUROPACE, 2002, 4 (02): : 113 - 119
  • [8] Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
    Reddy, Vivek Y.
    Exner, Derek V.
    Cantillon, Daniel J.
    Doshi, Rahul
    Bunch, T. Jared
    Tomassoni, Gery F.
    Friedman, Paul A.
    Estes, N. A. Mark, III
    Ip, John
    Niazi, Imran
    Plunkitt, Kenneth
    Banker, Rajesh
    Porterfield, James
    Ip, James E.
    Dukkipati, Srinivas R.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (12) : 1125 - 1135
  • [9] A Leadless Intracardiac Transcatheter Pacing System
    Reynolds, Dwight
    Duray, Gabor Z.
    Omar, Razali
    Soejima, Kyoko
    Neuzil, Petr
    Zhang, Shu
    Narasimhan, Calambur
    Steinwender, Clemens
    Brugada, Josep
    Lloyd, Michael
    Roberts, Paul R.
    Sagi, Venkata
    Hummel, John
    Bongiorni, Maria Grazia
    Knops, Reinoud E.
    Ellis, Christopher R.
    Gornick, Charles C.
    Bernabei, Matthew A.
    Laager, Verla
    Stromberg, Kurt
    Williams, Eric R.
    Hudnall, J. Harrison
    Ritter, Philippe
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (06) : 533 - 541
  • [10] A leadless pacemaker in the real-world setting: The Micra Transcatheter Pacing System Post-Approval Registry
    Roberts, Paul R.
    Clementy, Nicolas
    Al Samadi, Faisal
    Garweg, Christophe
    Martinez-Sande, Jose Luis
    Iacopino, Saverio
    Johansen, Jens Brock
    Prat, Xavier Vinolas
    Kowal, Robert C.
    Klug, Didier
    Mont, Lluis
    Steffel, Jan
    Li, Shelby
    Van Osch, Dirk
    El-Chami, Mikhael F.
    [J]. HEART RHYTHM, 2017, 14 (09) : 1375 - 1379