共 48 条
Clinical analysis of CAD-CAM milled and printed complete dentures using computerized occlusal force analyser
被引:24
|作者:
Chaturvedi, Saurabh
[1
]
Addas, Mohamed Khaled
[1
]
Alqahtani, Nasser M.
[1
]
Al Ahmari, Nasser M.
[1
]
Alfarsi, Mohammed A.
[1
]
机构:
[1] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha, Saudi Arabia
关键词:
Digital dentures;
T-Scan;
occlusal forces;
subtractive technique;
additive technique milling;
CAD-CAM;
LINGUALIZED OCCLUSION;
PROSTHESIS;
MOVEMENT;
TEETH;
D O I:
10.3233/THC-202766
中图分类号:
R19 [保健组织与事业(卫生事业管理)];
学科分类号:
摘要:
BACKGROUND: Digital complete dentures (CDs) by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques (milling and three-dimensional (3-D) printing) have been evaluated clinically and provided satisfactory results. But clinical studies assessing occlusal forces by digital dentures are lacking. OBJECTIVES: To compare the occlusal force parameters in complete dentures (CDs) fabricated by milling, 3-D printing and conventional techniques having 3 commonly used occlusal schemes, using computerized occlusal force analysis system (Tech-Scan III- T-Scan III). METHODS: A total of 45 CDs were fabricated for 5 patients. Nine sets of CDs were made for each patient and were divided into 3 groups: Conventional CDs (CCD), Milled CDs (MCD), and 3-D printed CDs (3-DP CD). The CDs in each group were further divided into 3 sub-groups based on occlusion schemes - bilateral balanced (BBO), lingualized (LO) and mono plane (MP). Occlusal force analysis [percentage (%) of occlusal force applied on the right and left sides of the arch difference between them, centralization of forces and % of maximum occlusal/bite force] was done using computerized occlusal analysis system (T-Scan III) at the time of denture insertion. Univariate regression analysis and logistic regression analysis were performed (p < 0.05). RESULTS: The intergroup comparison of force distribution on right and left side in CDs fabricated by various techniques showed insignificant differences (p > 0.05) but statistically significant differences (p < 0.01) were found in right-left side force difference, maximum bite force % and centralization of forces. The maximum force difference on right and left side was observed CCD with MO (37.48 +/- 1.03 N) and maximum occlusal-bite force % was observed for 3-DPCD with LO (95.40 +/- 1.30 N). In comparison to 3-DP CD, the chances of centre of force out of ellipse (centralization of forces) was 3.36 and 2.15 times more in CCD and MCD techniques made CDs respectively. CONCLUSIONS: The occlusal parameters in CDs were affected by the fabrication techniques and occlusal schemes of CDs. The digital CDs retain adjusted occlusal schemes better and 3-DP CDs with BBO and LO occlusal schemes provided centralization of forces, better distribution and high maximum occlusal force % respectively.
引用
收藏
页码:797 / 811
页数:15
相关论文