Clinical analysis of CAD-CAM milled and printed complete dentures using computerized occlusal force analyser

被引:24
|
作者
Chaturvedi, Saurabh [1 ]
Addas, Mohamed Khaled [1 ]
Alqahtani, Nasser M. [1 ]
Al Ahmari, Nasser M. [1 ]
Alfarsi, Mohammed A. [1 ]
机构
[1] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha, Saudi Arabia
关键词
Digital dentures; T-Scan; occlusal forces; subtractive technique; additive technique milling; CAD-CAM; LINGUALIZED OCCLUSION; PROSTHESIS; MOVEMENT; TEETH;
D O I
10.3233/THC-202766
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Digital complete dentures (CDs) by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques (milling and three-dimensional (3-D) printing) have been evaluated clinically and provided satisfactory results. But clinical studies assessing occlusal forces by digital dentures are lacking. OBJECTIVES: To compare the occlusal force parameters in complete dentures (CDs) fabricated by milling, 3-D printing and conventional techniques having 3 commonly used occlusal schemes, using computerized occlusal force analysis system (Tech-Scan III- T-Scan III). METHODS: A total of 45 CDs were fabricated for 5 patients. Nine sets of CDs were made for each patient and were divided into 3 groups: Conventional CDs (CCD), Milled CDs (MCD), and 3-D printed CDs (3-DP CD). The CDs in each group were further divided into 3 sub-groups based on occlusion schemes - bilateral balanced (BBO), lingualized (LO) and mono plane (MP). Occlusal force analysis [percentage (%) of occlusal force applied on the right and left sides of the arch difference between them, centralization of forces and % of maximum occlusal/bite force] was done using computerized occlusal analysis system (T-Scan III) at the time of denture insertion. Univariate regression analysis and logistic regression analysis were performed (p < 0.05). RESULTS: The intergroup comparison of force distribution on right and left side in CDs fabricated by various techniques showed insignificant differences (p > 0.05) but statistically significant differences (p < 0.01) were found in right-left side force difference, maximum bite force % and centralization of forces. The maximum force difference on right and left side was observed CCD with MO (37.48 +/- 1.03 N) and maximum occlusal-bite force % was observed for 3-DPCD with LO (95.40 +/- 1.30 N). In comparison to 3-DP CD, the chances of centre of force out of ellipse (centralization of forces) was 3.36 and 2.15 times more in CCD and MCD techniques made CDs respectively. CONCLUSIONS: The occlusal parameters in CDs were affected by the fabrication techniques and occlusal schemes of CDs. The digital CDs retain adjusted occlusal schemes better and 3-DP CDs with BBO and LO occlusal schemes provided centralization of forces, better distribution and high maximum occlusal force % respectively.
引用
收藏
页码:797 / 811
页数:15
相关论文
共 48 条
  • [31] Effect of aging on dimensional accuracy and color stability of CAD-CAM milled and 3D-printed denture base resins: a comparative in-vitro study
    Gad, Marwa A.
    Abdelhamid, Ahmed M.
    ElSamahy, Mahmoud
    Abolgheit, Salma
    Hanno, Kenda I.
    BMC ORAL HEALTH, 2024, 24 (01):
  • [32] Evaluation of the Effect of Different Construction Techniques of CAD-CAM Milled, 3D-Printed, and Polyamide Denture Base Resins on Flexural Strength: An In Vitro Comparative Study
    Zeidan, Ahmed Abd El-Latif
    Sherif, Ahmed Fadlallah
    Baraka, Yasser
    Abualsaud, Reem
    Abdelrahim, Ramy Abdallah
    Gad, Mohammed M.
    Helal, Mohamed A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 77 - 82
  • [33] Tissue surface adaptation of CAD-CAM maxillary and mandibular complete denture bases manufactured by digital light processing: A clinical study
    Yoon, Se-Na
    Oh, Kyung Chul
    Lee, Sang J.
    Han, Jung-Suk
    Yoon, Hyung-In
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06) : 682 - 689
  • [34] Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns-cast-free vs 3D printed cast-based
    Graf, Tobias
    Gueth, Jan-Frederik
    Diegritz, Christian
    Liebermann, Anja
    Schweiger, Josef
    Schubert, Oliver
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (06) : 351 - 360
  • [35] Impact of in vitro findings on clinical protocols for the adhesion of CAD-CAM blocks: A systematic integrative review and meta-analysis
    Calheiros-Lobo, Maria Joao
    Carbas, Ricardo
    Silva, Lucas F. M. da
    Pinho, Teresa
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06) : 1051 - 1070
  • [36] Evaluation of the Influence of Build Orientation on the Surface Roughness and Flexural Strength of 3D-Printed Denture Base Resin and Its Comparison with CAD-CAM Milled Denture Base Resin
    Alharethi, Naji Ahmad
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (01) : 321 - 328
  • [37] Interdisciplinary Management of a Patient with Dentinogenesis Imperfecta Type II Using a Combination of CAD-CAM and Analog Techniques: A Clinical Report
    Azpiazu-Flores, Francisco X.
    Knobloch, Lisa A.
    Larsen, Peter E.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (08): : 647 - 654
  • [38] Rehabilitation of Ectodermal Dysplasia Using CAD/CAM Mandibular Complete Denture and Maxillary Overdenture: A Clinical Report
    Alqarni, Hatem
    Alzeghaibi, Faisal
    Alotaibi, Sahar
    Alamri, Raghad
    Aljohani, Raghad
    Altoman, Majed S.
    Alfaifi, Mohammed A.
    CASE REPORTS IN DENTISTRY, 2024, 2024
  • [39] CAD/CAM versus traditional complete dentures: A systematic review and meta-analysis of patient- and clinician-reported outcomes and costs
    Jafarpour, Dana
    Haricharan, Praveen Bhoopathi
    de Souza, Raphael Freitas
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (09) : 1911 - 1924
  • [40] A digital approach integrating facial scanning in a CAD-CAM workflow for complete-mouth implant-supported rehabilitation of patients with edentulism: A pilot clinical study
    Hassan, Bassam
    Gonzalez, Beatriz Gimenez
    Tahmaseb, Ali
    Greven, Marcus
    Wismeijer, Daniel
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04) : 486 - 492