Clinical analysis of CAD-CAM milled and printed complete dentures using computerized occlusal force analyser

被引:24
|
作者
Chaturvedi, Saurabh [1 ]
Addas, Mohamed Khaled [1 ]
Alqahtani, Nasser M. [1 ]
Al Ahmari, Nasser M. [1 ]
Alfarsi, Mohammed A. [1 ]
机构
[1] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha, Saudi Arabia
关键词
Digital dentures; T-Scan; occlusal forces; subtractive technique; additive technique milling; CAD-CAM; LINGUALIZED OCCLUSION; PROSTHESIS; MOVEMENT; TEETH;
D O I
10.3233/THC-202766
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Digital complete dentures (CDs) by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques (milling and three-dimensional (3-D) printing) have been evaluated clinically and provided satisfactory results. But clinical studies assessing occlusal forces by digital dentures are lacking. OBJECTIVES: To compare the occlusal force parameters in complete dentures (CDs) fabricated by milling, 3-D printing and conventional techniques having 3 commonly used occlusal schemes, using computerized occlusal force analysis system (Tech-Scan III- T-Scan III). METHODS: A total of 45 CDs were fabricated for 5 patients. Nine sets of CDs were made for each patient and were divided into 3 groups: Conventional CDs (CCD), Milled CDs (MCD), and 3-D printed CDs (3-DP CD). The CDs in each group were further divided into 3 sub-groups based on occlusion schemes - bilateral balanced (BBO), lingualized (LO) and mono plane (MP). Occlusal force analysis [percentage (%) of occlusal force applied on the right and left sides of the arch difference between them, centralization of forces and % of maximum occlusal/bite force] was done using computerized occlusal analysis system (T-Scan III) at the time of denture insertion. Univariate regression analysis and logistic regression analysis were performed (p < 0.05). RESULTS: The intergroup comparison of force distribution on right and left side in CDs fabricated by various techniques showed insignificant differences (p > 0.05) but statistically significant differences (p < 0.01) were found in right-left side force difference, maximum bite force % and centralization of forces. The maximum force difference on right and left side was observed CCD with MO (37.48 +/- 1.03 N) and maximum occlusal-bite force % was observed for 3-DPCD with LO (95.40 +/- 1.30 N). In comparison to 3-DP CD, the chances of centre of force out of ellipse (centralization of forces) was 3.36 and 2.15 times more in CCD and MCD techniques made CDs respectively. CONCLUSIONS: The occlusal parameters in CDs were affected by the fabrication techniques and occlusal schemes of CDs. The digital CDs retain adjusted occlusal schemes better and 3-DP CDs with BBO and LO occlusal schemes provided centralization of forces, better distribution and high maximum occlusal force % respectively.
引用
收藏
页码:797 / 811
页数:15
相关论文
共 48 条
  • [21] Evaluation of surface properties and elastic modulus of CAD-CAM Milled, 3D printed, and compression moulded denture base resins: An in vitro study
    Zeidan, Ahmed Abd El-latif
    Elrahim, Ramy Abdallah Abd
    El Hakim, Adel Fawzy Abd
    Harby, Nehad Mohammed
    Helal, Mohamed Ahmed
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2022, 12 (06) : 630 - 637
  • [22] CAD/CAM FABRICATED COMPLETE DENTURES: CONCEPTS AND CLINICAL METHODS OF OBTAINING REQUIRED MORPHOLOGICAL DATA
    Goodacre, Charles J.
    Garbacea, Antoanela
    Naylor, W. Patrick
    Daher, Tony
    Marchack, Christopher B.
    Lowry, Jean
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (01) : 34 - 46
  • [23] Physical, Mechanical, and Anti-Biofilm Formation Properties of CAD-CAM Milled or 3D Printed Denture Base Resins: In Vitro Analysis
    Carvalho Porto de Freitas, Rodrigo Falcao
    Duarte, Simone
    Feitosa, Sabrina
    Dutra, Vinicius
    Lin, Wei-Shao
    Dias Panariello, Beatriz Helena
    Porto Carreiro, Adriana da Fonte
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 : 38 - 44
  • [24] In vitro analysis of the fracture resistance of CAD-CAM monolithic lithium disilicate molar crowns with different occlusal thickness
    Sorrentino, R.
    Nagasawa, Y.
    Infelis, M.
    Bonadeo, G.
    Ferrari, M.
    JOURNAL OF OSSEOINTEGRATION, 2018, 10 (02) : 50 - 56
  • [25] A comparative study of strength and surface properties of permanent 3D-printed resins with CAD-CAM milled fixed dental prostheses
    Gad, Mohammed M.
    Al Mahfoudh, Hoor A.
    Al Mahfuth, Fatimah A.
    Hashim, Kouthar A.
    Khan, Soban Q.
    Al-Qarni, Faisal D.
    Baba, Nadim Z.
    Al-Harbi, Fahad A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [26] Surface hardness and wear resistance of prefabricated and CAD-CAM milled artificial teeth: A cross-over clinical study
    Ali, Sarah Abdelaal
    Abozaed, Heba Wageh
    Jazar, Husn A.
    Mostafa, Aisha Z. H.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (01): : 15 - 25
  • [27] Comparison of surface roughness and color stainability of 3-dimensionally printed interim prosthodontic material with conventionally fabricated and CAD-CAM milled materials
    Tasin, Simge
    Ismatullaev, Artur
    Usumez, Aslihan
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05) : 1094 - 1101
  • [28] Clinical outcomes of milled, 3D-printed, and conventional complete dentures in edentulous patients: A systematic review and meta-analysis
    Zandinejad, Amirali
    Floriani, Franciele
    Lin, Wei-Shao
    Naimi-Akbar, Aron
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (08): : 736 - 747
  • [29] Oral features and computerized rehabilitation of a young patient with CHARGE syndrome using minimally invasive long-term interim CAD-CAM restorations
    Liebermann, Anja
    Rafael, Caroline Freitas
    Edelhoff, Daniel
    Ramberger, Marc
    Schweiger, Josef
    Maziero Volpato, Claudia Angela
    Pour, Reza Saeidi
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04) : 453 - 458
  • [30] CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes
    Srinivasan, Murali
    Kamnoedboon, Porawit
    McKenna, Gerald
    Angst, Lea
    Schimmel, Martin
    Ozcan, Mutlu
    Muller, Frauke
    JOURNAL OF DENTISTRY, 2021, 113