Clinical analysis of CAD-CAM milled and printed complete dentures using computerized occlusal force analyser

被引:27
作者
Chaturvedi, Saurabh [1 ]
Addas, Mohamed Khaled [1 ]
Alqahtani, Nasser M. [1 ]
Al Ahmari, Nasser M. [1 ]
Alfarsi, Mohammed A. [1 ]
机构
[1] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha, Saudi Arabia
关键词
Digital dentures; T-Scan; occlusal forces; subtractive technique; additive technique milling; CAD-CAM; LINGUALIZED OCCLUSION; PROSTHESIS; MOVEMENT; TEETH;
D O I
10.3233/THC-202766
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Digital complete dentures (CDs) by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques (milling and three-dimensional (3-D) printing) have been evaluated clinically and provided satisfactory results. But clinical studies assessing occlusal forces by digital dentures are lacking. OBJECTIVES: To compare the occlusal force parameters in complete dentures (CDs) fabricated by milling, 3-D printing and conventional techniques having 3 commonly used occlusal schemes, using computerized occlusal force analysis system (Tech-Scan III- T-Scan III). METHODS: A total of 45 CDs were fabricated for 5 patients. Nine sets of CDs were made for each patient and were divided into 3 groups: Conventional CDs (CCD), Milled CDs (MCD), and 3-D printed CDs (3-DP CD). The CDs in each group were further divided into 3 sub-groups based on occlusion schemes - bilateral balanced (BBO), lingualized (LO) and mono plane (MP). Occlusal force analysis [percentage (%) of occlusal force applied on the right and left sides of the arch difference between them, centralization of forces and % of maximum occlusal/bite force] was done using computerized occlusal analysis system (T-Scan III) at the time of denture insertion. Univariate regression analysis and logistic regression analysis were performed (p < 0.05). RESULTS: The intergroup comparison of force distribution on right and left side in CDs fabricated by various techniques showed insignificant differences (p > 0.05) but statistically significant differences (p < 0.01) were found in right-left side force difference, maximum bite force % and centralization of forces. The maximum force difference on right and left side was observed CCD with MO (37.48 +/- 1.03 N) and maximum occlusal-bite force % was observed for 3-DPCD with LO (95.40 +/- 1.30 N). In comparison to 3-DP CD, the chances of centre of force out of ellipse (centralization of forces) was 3.36 and 2.15 times more in CCD and MCD techniques made CDs respectively. CONCLUSIONS: The occlusal parameters in CDs were affected by the fabrication techniques and occlusal schemes of CDs. The digital CDs retain adjusted occlusal schemes better and 3-DP CDs with BBO and LO occlusal schemes provided centralization of forces, better distribution and high maximum occlusal force % respectively.
引用
收藏
页码:797 / 811
页数:15
相关论文
共 41 条
[1]   Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study [J].
Babu, Sumanth ;
Manjunath, Shaurya ;
Vajawat, Mayuri .
CONTEMPORARY CLINICAL DENTISTRY, 2016, 7 (01) :36-40
[2]  
Badel T., 2001, ACTA STOMAT CROAT, V35, P381
[3]   Comparison between conventional and computerised methods in the assessment of an occlusal scheme [J].
Bernardo Dias, Ricardo Antonio ;
Pascoal Rodrigues, Maria Joao ;
Messias, Ana Lucia ;
Deometrio Alves Guerra, Fernando Alberto ;
Manfredini, Daniele .
JOURNAL OF ORAL REHABILITATION, 2020, 47 (02) :221-228
[4]   Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes [J].
Bidra, Avinash S. ;
Farrell, Kimberly ;
Burnham, David ;
Dhingra, Ajay ;
Taylor, Thomas D. ;
Kuo, Chia-Ling .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) :578-586
[5]   Fabricating Complete Dentures with CAD/CAM and RP Technologies [J].
Bilgin, Mehmet Selim ;
Erdem, Ali ;
Aglarci, Osman Sami ;
Dilber, Erhan .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (07) :576-579
[6]   Marginal and internal fit of provisional crowns fabricated using 3D printing technology [J].
Chaturvedi, Saurabh ;
Alqahtani, Nasser M. ;
Addas, Mohamed Khaled ;
Alfarsi, Mohammed A. .
TECHNOLOGY AND HEALTH CARE, 2020, 28 (06) :635-642
[7]   RESPONSE OF THE ORAL-MUCOSA TO DENTURE WEARING [J].
COOK, RJ .
JOURNAL OF DENTISTRY, 1991, 19 (03) :135-147
[8]  
Davda K, 2017, EUR J PROSTHODONT RE, V25, P186, DOI 10.1922/EJPRD_01716Davda07
[9]   Evaluation of the Accuracy of a System to Align Occlusal Dynamic Data on 3D Digital Casts [J].
de Prado, Inigo ;
Iturrate, Mikel ;
Minguez, Rikardo ;
Solaberrieta, Eneko .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[10]   Comparison of nonscheduled, postinsertion adjustment visits for complete dentures fabricated with conventional and CAD-CAM protocols: A clinical study [J].
Drago, Carl ;
Borgert, Andrew J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (05) :459-466