Current Concepts for Experimental Micro-CT in Small Animals

被引:4
作者
Bag, S. [1 ]
Schambach, S. J. [1 ]
Boll, H. [1 ]
Schilling, L. [2 ]
Groden, C. [1 ]
Brockmann, M. A. [1 ]
机构
[1] Heidelberg Univ, Med Fak Mannheim, Abt Neuroradiol, D-61867 Mannheim, Germany
[2] Heidelberg Univ, Med Fak Mannheim, Abt Neurochirurg Forsch, D-61867 Mannheim, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2010年 / 182卷 / 05期
关键词
CT; experimental; in vivo; small animal; micro-CT; RAY COMPUTED-TOMOGRAPHY; SELECTIVE CONTRAST AGENT; CEREBRAL BLOOD-VOLUME; GADOPENTETATE DIMEGLUMINE; GLIOMA MODEL; RADIATION; TUMORS; LIVER; LUNG; VISUALIZATION;
D O I
10.1055/s-0029-1245301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The number of publications describing the use of micro-computed tomography (mu CT) for preclinical in vivo imaging of small animals has risen considerably within the last few years. The purpose of this review is to familiarize the reader with the basic principles of mu CT, to present successful experimental approaches in order of the evaluated organ system, and to highlight limitations that need to be considered when planning mu CT-based studies.
引用
收藏
页码:390 / 403
页数:14
相关论文
共 98 条
  • [1] High-resolution blood-brain barrier permeability and blood volume imaging using quantitative synchrotron radiation computed tomography:: study on an F98 rat brain glioma
    Adam, JF
    Nemoz, C
    Bravin, A
    Fiedler, S
    Bayat, S
    Monfraix, S
    Berruyer, G
    Charvet, AM
    Le Bas, JF
    Elleaume, H
    Estève, F
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2005, 25 (02) : 145 - 153
  • [2] Absolute cerebral blood volume and blood flow measurements based on synchrotron radiation quantitative computed tomography
    Adam, JF
    Elleaume, H
    Le Duc, G
    Corde, S
    Charvet, AM
    Troprès, I
    Le Bas, JF
    Estève, F
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2003, 23 (04) : 499 - 512
  • [3] In-vivo high-resolution X-ray microtomography for liver and spleen tumor assessment in mice
    Almajdub, M.
    Nejjari, M.
    Poncet, G.
    Magnier, L.
    Chereul, E.
    Roche, C.
    Janier, M.
    [J]. CONTRAST MEDIA & MOLECULAR IMAGING, 2007, 2 (02) : 88 - 93
  • [4] Micro-CT with respiratory and cardiac gating
    Badea, C
    Hedlund, LW
    Johnson, GA
    [J]. MEDICAL PHYSICS, 2004, 31 (12) : 3324 - 3329
  • [5] Badea C., 2005, MOL IMAGING, V4, P110
  • [6] In vivo small-animal imaging using micro-CT and digital subtraction angiography
    Badea, C. T.
    Drangova, M.
    Holdsworth, D. W.
    Johnson, G. A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) : R319 - R350
  • [7] Left ventricle volume measurements in cardiac micro-CT: The impact of radiation dose and contrast agent
    Badea, Cristian T.
    Wetzel, Arthur W.
    Mistry, Nilesh
    Pomerantz, Stuart
    Nave, Demian
    Johnson, G. Allan
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (03) : 239 - 250
  • [8] A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating
    Badea, Cristian T.
    Schreibmann, Eduard
    Fox, Tim
    [J]. MEDICAL PHYSICS, 2008, 35 (04) : 1170 - 1179
  • [9] Imaging methods for morphological and functional phenotyping of the rodent heart
    Badea, CT
    Bucholz, E
    Hedlund, LW
    Rockman, HA
    Johnson, GA
    [J]. TOXICOLOGIC PATHOLOGY, 2006, 34 (01) : 111 - 117
  • [10] Mapping the Zonal Organization of Tumor Perfusion and Permeability in a Rat Glioma Model by Using Dynamic Contrast-enhanced Synchrotron Radiation CT
    Balvay, Daniel
    Tropres, Irene
    Billet, Romain
    Joubert, Aurelie
    Peoc'h, Michel
    Cuenod, Charles A.
    Le Duc, Geraldine
    [J]. RADIOLOGY, 2009, 250 (03) : 692 - 702