OBJECTIVE. The purpose of this study was to compare attenuation values (in Hounsfield units) and degree of enhancement (attenuation change) in renal masses using 120-kVp polychromatic (conventional) CT and 70-keV monochromatic dual-energy CT (DECT). MATERIALS AND METHODS. Twenty-two patients with 39 renal masses (24 Bosniak category I and II cysts and 15 solid masses under active surveillance) underwent conventional CT (120-kVp unenhanced and contrast-enhanced CT) and rapid kilovoltage-switching DECT (120-kVp unenhanced CT and 70-keV contrast-enhanced CT). The mean (+/- SD) time between scans was 648 +/- 943 days. A radiologist measured attenuation on matched image sets coregistered between examinations. Absolute attenuation and attenuation change were compared using independent t tests, Pearson correlation, and Bland Altman analysis. RESULTS. There was no difference in attenuation on 120-kVp versus 70-keV contrast-enhanced CT images for cysts (9.5 +/- 5.5 HU [range, -2 to 20 HU] vs 10.1 +/- 4.6 HU [range, -2 to 16 HU]; p = 0.33) and solid masses (110.1 +/- 72.9 HU [range, 35-267 HU] vs 119.1 +/- 73.7 HU [range, 33-265 I IU]; p = 0.04). There also was no difference in attenuation change for 120-kVp contrast-enhanced CT minus 120-kVp unenhanced CT (cysts, 3.5 +/- 3.9 HU [range, -2 to 13 HU]; solid masses, 80.7 +/- 73.3 HU [range, 9-227 HU]; p = 0.45) or for 70-keV contrast-enhanced CT minus 120-kVp unenhanced CT (cysts, 4.3 +/- 41 HU [range, -3 to 12 HU]; solid masses, 89.8 +/- 74.1 I IU [range, 7-226 I IU]; p = 0.04). The correlation was strong to almost perfect (beta = 0.83-0.98) with substantial agreement There was no difference in attenuation of cysts and solid masses comparing 120-kVp acquisitions acquired at different time points (p = 0.200.92). The correlation was strong to almost perfect (beta= 0.72-0.95) with substantial agreement. CONCLUSION. There are no differences in absolute attenuation or degree of enhancement comparing 70-keV monochromatic CT to conventional 120-kVp CT in renal cysts and solid masses.
引用
收藏
页码:789 / 796
页数:8
相关论文
共 34 条
[1]  
American College of Radiology, CT ACCR PROGR TEST I
[2]   Renal cysts: Is attenuation artifactually increased on contrast-enhanced CT images? [J].
Bae, KT ;
Heiken, JP ;
Siegel, CL ;
Bennett, HF .
RADIOLOGY, 2000, 216 (03) :792-796
[3]   Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 242 (01) :109-119
[4]   Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses [J].
Chandarana, Hersh ;
Megibow, Alec J. ;
Cohen, Benjamin A. ;
Srinivasan, Ramya ;
Kim, Danny ;
Leidecker, Christianne ;
Macari, Michael .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :W693-W700
[5]   Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis [J].
Connolly, Michael J. ;
McInnes, Matthew D. F. ;
El-Khodary, Mohamed ;
McGrath, Trevor A. ;
Schieda, Nicola .
EUROPEAN RADIOLOGY, 2017, 27 (10) :4324-4335
[6]   Evaluation of pseudoenhancement of renal cysts during contrast-enhanced CT [J].
Coulam, CH ;
Sheafor, DH ;
Leder, RA ;
Paulson, EK ;
DeLong, DM ;
Nelson, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :493-498
[7]   Comparison of Contrast-Enhanced Multiphase Renal Protocol CT Versus MRI for Diagnosis of Papillary Renal Cell Carcinoma [J].
Dilauro, Marc ;
Quon, Matthew ;
McInnes, Matthew D. F. ;
Vakili, Maryam ;
Chung, Andrew ;
Flood, Trevor A. ;
Schieda, Nicola .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (02) :319-325
[8]   Differentiation of Papillary Renal Cell Carcinoma Subtypes on CT and MRI [J].
Egbert, Nathan D. ;
Caoili, Elaine M. ;
Cohan, Richard H. ;
Davenport, Matthew S. ;
Francis, Isaac R. ;
Kunju, L. Priya ;
Ellis, James H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) :347-355
[9]   Adrenal lesions: Attenuation measurement differences between CT scanners [J].
Hahn, Peter F. ;
Blake, Michael A. ;
Boland, Giles W. L. .
RADIOLOGY, 2006, 240 (02) :458-463
[10]   ACR Appropriateness Criteria Indeterminate Renal Mass [J].
Heilbrun, Marta E. ;
Remer, Erick M. ;
Casalino, David D. ;
Beland, Michael D. ;
Bishoff, Jay T. ;
Blaufox, M. Donald ;
Coursey, Courtney A. ;
Goldfarb, Stanley ;
Harvin, Howard J. ;
Nikolaidis, Paul ;
Preminger, Glenn M. ;
Raman, Steven S. ;
Sahni, Anik ;
Vikram, Raghunandan ;
Weinfeld, Robert M. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (04) :333-341