Single-tooth Morse taper connection implants after 1 year of functional loading: a multicentre study on 302 patients

被引:0
|
作者
Mangano, Carlo [1 ]
Mangano, Francesco
Piattelli, Adriano [2 ]
Lezzi, Giovanna [2 ]
Mangano, Alberto [3 ]
La Colla, Luca [3 ]
Mangano, Alessandro
机构
[1] Univ Varese, Sch Dent, Varese, Italy
[2] Univ G dAnnunzio, Sch Dent, Chieti, Italy
[3] S Raffaele Univ, Sch Med, Milan, Italy
关键词
implant abutment connection; Morse taper connection implants; prosthetic complications; single-tooth restorations;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This prospective clinical study evaluated the survival rate and the implant-crown success of 314 Morse taper connection implants, used for single-tooth replacement, after 1 year of functional loading. Materials and methods: Over a 4-year period (January 2003 to January 2007), 314 implants (168 maxilla, 146 mandible) were inserted in 302 patients (128 males, 174 females, aged between 23 to 79 years) in six different clinical centres. The sites included anterior (n = 118) and posterior (n = 196) teeth. To evaluate implant-crown success, the following clinical, prosthetic and radiographic parameters were assessed: modified plaque index (mPI), modified sulcus bleeding index (mBI), probing depth (PD), distance from the implant crown margin to the corona] border of the pen-implant mucosa (DIM), width of keratinised mucosa (KM), prosthesis function, and the distance between the implant shoulder and first crestal bone-implant contact (DIB). Success criteria included: absence of suppuration and mobility, PD<5.0 mm, absence of prosthetic complications, absence of continuous pen-implant radiolucency, and DIB<1.5 mm after 1-year of functional loading. Prosthetic restorations were all-ceramic (n = 116) and metal-ceramic (n = 198) crowns. Results: The implant survival rate was 98.4% (5 implant losses, 1 drop-out). A few prosthetic complications (0.6% implant-abutment loosening) were reported. The mean DIB was 0.887 +/- 0.308 mm. Among the survived implants (308), four did not fulfil the success criteria, giving an implant-crown success of 98.7%. Conclusion: The use of Morse taper connection implants represents a successful procedure for single-tooth replacement, in the anterior and posterior areas of both arches. The high mechanical stability may reduce prosthetic complications.
引用
收藏
页码:305 / 315
页数:11
相关论文
共 50 条
  • [1] Prosthetic Complications Affecting Single-Tooth Morse-Taper Connection Implants
    Mangano, Francesco
    Lucchina, Alberta Greco
    Brucoli, Matteo
    Migliario, Mario
    Mortellaro, Carmen
    Mangano, Carlo
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2255 - 2262
  • [2] Prospective Clinical Evaluation of 307 Single-Tooth Morse Taper-Connection Implants: A Multicenter Study
    Mangano, Carlo
    Mangano, Francesco
    Piattelli, Adriano
    Iezzi, Giovanna
    Mangano, Alberto
    La Colla, Luca
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (02) : 394 - 400
  • [3] Single tooth replacement by Morse taper connection implants: A retrospective study of 80 implants
    Mangano, C
    Bartolucci, EG
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2001, 16 (05) : 675 - 680
  • [4] Single-tooth Morse taper connection implants placed in fresh extraction sockets of the anterior maxilla: an aesthetic evaluation
    Mangano, Francesco
    Mangano, Carlo
    Ricci, Massimiliano
    Sammons, Rachel Lilian
    Shibli, Jamil Awad
    Piattelli, Adriano
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (11) : 1302 - 1307
  • [5] Immediate loading of post-extractive single-tooth implants: a 1-year prospective study
    Cristalli, Maria Paola
    Marini, Roberta
    La Monaca, Gerardo
    Sepe, Claudio
    Tonoli, Federica
    Annibali, Susanna
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) : 1070 - 1079
  • [6] Prospective clinical evaluation of 1920 Morse taper connection implants: results after 4 years of functional loading
    Mangano, C.
    Mangano, F.
    Piattelli, A.
    Iezzi, G.
    Mangano, A.
    La Colla, L.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) : 254 - 261
  • [7] Single-Tooth Morse Taper Connection Implant Placed in Grafted Site of the Anterior Maxilla: Clinical and Radiographic Evaluation
    Guido Mangano, Francesco
    Zecca, Piero
    Luongo, Fabrizia
    Iezzi, Giovanna
    Mangano, Carlo
    CASE REPORTS IN DENTISTRY, 2014, 2014
  • [8] Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year
    Lorenzoni, M
    Pertl, C
    Zhang, KH
    Wimmer, G
    Wegscheider, WA
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (02) : 180 - 187
  • [9] Esthetic Evaluation of Single-Tooth Worse Taper Connection Implants Placed in Fresh Extraction Sockets or Healed Sites
    Mangano, Francesco G.
    Mangano, Carlo
    Ricci, Massimiliano
    Sammons, Rachel L.
    Shibli, Jamil A.
    Piattelli, Adriano
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (02) : 172 - 181
  • [10] Immediate versus staged loading single-tooth implants: An experimental study.
    Hanisch, O
    Mees, W
    Tatakis, DN
    Caplanis, N
    Bohsali, K
    Lozada, J
    Spiekermann, H
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 337 - 337