A Power Module for Grid Inverter With In-Built Short-Circuit Fault Current Capability

被引:28
|
作者
Shao, Weihua [1 ]
Wu, Ruizhu [2 ]
Ran, Li [1 ,2 ]
Jiang, Huaping [1 ]
Mawby, Philip A. [2 ]
Rogers, Daniel J. [3 ]
Green, Tim C. [4 ]
Coombs, Thomas [2 ]
Yardley, Kieran [2 ]
Kastha, Debaprasad [5 ]
Bajpai, Prabodh [5 ]
Zhou, Lin [1 ]
机构
[1] Chongqing Univ, Sch Elect Engn, Chongqing 400044, Peoples R China
[2] Univ Warwick, Sch Engn, Coventry CV4 7AL, W Midlands, England
[3] Univ Oxford, Dept Engn Sci, Oxford OX1 2JD, England
[4] Imperial Coll London, Dept Elect & Elect Engn, London SW7 2AZ, England
[5] IIT Kharagpur, Sch Energy Sci & Engn, Kharagpur 721302, W Bengal, India
基金
英国工程与自然科学研究理事会;
关键词
Phase change materials; Inverters; Fault currents; Heating systems; Synchronous generators; Insulated gate bipolar transistors; Circuit faults; IGBT power module; latent heat; overcurrent capability; packaging; phase change material; WIND TURBINES;
D O I
10.1109/TPEL.2020.2978656
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As grid codes evolve, inverter-interfaced renewable generation may be required to take greater responsibility for grid support. It may be obliged to source a large current during a short-circuit fault in the grid and provide large dynamic reactive power, beyond the inverter rating, for voltage recovery after the fault clearance. In this sense, the inverter-interfaced generating system would behave more similarly to a conventional synchronous machine. This is not yet mandatory but current technology cannot readily support it if required in the future, because the power semiconductors would overheat unless they are drastically derated. This study proposes a method to increase the power semiconductor's transient thermal capacity, and hence its short-term over-current capability, by integrating a phase-change material inside the power semiconductor module. Experiment and thermodynamic simulation across different materials are used to illustrate the feasibility of the concept and the factors that should be considered in such a design. The study shows that 1.5 p.u. (per unit) overcurrent could be achieved for 30 s, which is typical of synchronous generators; and 3.0 p.u. fault current could be achieved for 3 s. A custom-made 1200-V, 50-A IGBT half-bridge module integrating a liquid metal as the phase change material is compared with a conventional commercially available module. A validated simulation model is then used to further evaluate the proposal, regarding a 1700-V, 1000-A IGBT module for use in a wind turbine.
引用
收藏
页码:10567 / 10579
页数:13
相关论文
共 50 条
  • [31] Short-circuit Current Characteristics of Distributed Power and Fault Location Method after Distributed Power is Connected
    Zhao Dan
    Zhang Xinyu
    Wang Yang
    Tian Ye
    Wang Yanan
    Lang Yexing
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 1782 - 1786
  • [32] Short-Circuit Fault Current Calculation Method for the Multi-Terminal DC Grid Considering the DC Circuit Breaker
    Jia, Haipeng
    Yin, Jingyuan
    Wei, Tongzhen
    Huo, Qunhai
    Li, Jinke
    Wu, Lixin
    ENERGIES, 2020, 13 (06)
  • [33] A CURRENT FED INVERTER WITH INHERENT SHORT-CIRCUIT PROTECTION AND SUPPRESSION OF RINGING
    HOBSON, L
    TEBB, DW
    PUDNEY, C
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1986, 60 (04) : 431 - 437
  • [34] Practical Calculation for Bipolar Short-circuit Fault Current of Transmission Line in MMC-HVDC Grid
    Hao L.
    Li W.
    Wang Z.
    Gu Y.
    Wang G.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (05): : 68 - 76
  • [35] Short-Circuit Capability with GaN HEMTs
    Bisi, Davide
    Cruse, Bill
    Zuk, Philip
    Parikh, Primit
    Mishra, Umesh
    Hosoda, Tsutomu
    Kamiyama, Masamichi
    Kanamura, Masahito
    2022 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM (IRPS), 2022,
  • [36] Short-Circuit Switches Fault Analysis of Voltage Source Inverter using Spectrogram
    Abdullah, A. R.
    Ahmad, N. S.
    Bahari, N.
    Manap, M.
    Jidin, A.
    Jopri, M. H.
    2013 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2013, : 1808 - 1813
  • [37] Fault location method of IGBT short-circuit for a grid-tied Neutral-Point-Clamped inverter system
    Ma, Mingyao
    Meng, Xuesong
    Xiang, Nianwen
    Wang, Hanyu
    Zhang, Xing
    MICROELECTRONICS RELIABILITY, 2021, 126
  • [38] Current measurement and short-circuit protection of an IGBT based on module parasitics
    Oinoneni, Markus
    Laitineni, Matti
    Kyyra, Jorma
    2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,
  • [39] Fault location method of IGBT short-circuit for a grid-tied Neutral-Point-Clamped inverter system
    Ma, Mingyao
    Meng, Xuesong
    Xiang, Nianwen
    Wang, Hanyu
    Zhang, Xing
    Xiang, Nianwen (xiangnianwen@hfut.edu.cn), 1600, Elsevier Ltd (126):
  • [40] Distribution Fault Location using Short-circuit Fault Current Profile Approach
    Das, S.
    Kulkarni, S.
    Karnik, N.
    Santoso, S.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,