Development of a System for Measuring and Recording Ion Currents for an MI-1201IG Mass Spectrometer

被引:1
作者
Kolobov, V. V. [1 ]
Selivanov, V. N. [1 ]
Barannik, M. B. [1 ]
机构
[1] Russian Acad Sci, Ctr Phys & Technol Problems Energy Northern Areas, Kola Sci Ctr, Apatity 184209, Murmansk Oblast, Russia
关键词
MI-1201IG mass spectrometer; electrometric amplifier; high-resistivity feedback resistor; distributed capacitance; shielding rings system; full-scan mode; time constant; analog-to-digital converter;
D O I
10.1134/S1061934818130063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the complex modernization of an MI-1201IG isotope mass spectrometer, a new system for measuring and recording ion currents was developed, including an electrometric amplifier based on a high-resistivity (1 T) feedback resistor and a special chip located in the electrometer head. A recording circuit based on a high-precision analog-to-digital converter was included in the new unit for controlling the separating magnetic field and measuring the ion current. In designing the system circuit, the task was not only to increase the sensitivity and expand the dynamic range when measuring the intensity of peaks in mass spectra but also to decrease the time constant of the analog part of the measuring system for the undistorted transfer of the ion current distribution form to the input of the analog-to-digital converter in a dynamic mode. Ashielding system was designed that distributes the electric field gradient on the surface of a high-resistivity feedback resistor, which made it possible to compensate its distributed capacitance and decrease the time constant of the electrometric amplifier to 0.2 s. To compensate for the distortion of the shape of the ion current pulses, caused by the in-to-out stray capacitance of the electrometer's amplifier chip, a special circuit was developed. This results in that the end-to-end frequency response of the new system for measuring and detecting ion currents is determined only by the upper cut-off frequency of the low-pass filters of 10 Hz. The high-speed measuring system made it possible to improve the mass-spectrometric resolution and mass accuracy and to increase full-spectrum scan rate. The working range of the new system for measuring and recording ion currents is 1 x 10(-15) to 3 x 10(-12) A. The measured equivalent root-mean-square input noise is 0.86 fA at the sampling frequency of 10 Hz and the integration time of 1 s and 0.14 fA at the integration time of 10 s.
引用
收藏
页码:1282 / 1291
页数:10
相关论文
共 6 条
[1]  
Anso M.Kh, 1984, THESIS
[2]  
Bondarenko I.B., 2012, ELEKTRORADIOELEMEN 1
[3]   The tritium-helium-3 method and its application to groundwater dating by the example of the Kirovsk mine region, Murmansk oblast [J].
Gudkov, A. V. ;
Kamensky, I. L. ;
Melikhova, G. S. ;
Skiba, V. I. ;
Tokarev, I. V. ;
Tolstikhin, I. N. .
GEOCHEMISTRY INTERNATIONAL, 2014, 52 (07) :587-594
[4]   The comprehensive upgrading of an MI-1201 mass spectrometer [J].
Ivanov, VP ;
Moiseeva, TG ;
Trofimov, AS ;
Dryannov, AI ;
Sysoev, AA ;
Sysoev, AA .
INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2005, 48 (03) :321-327
[5]  
[Сапрыгин А.В. Saprygin A.V.], 2006, [Масс-спектрометрия, Mass-spektrometriya], V3, P201
[6]  
Shubin V.M., 2003, NAUCHN PRIBOROSTR, V13, P64