Classification and 3D averaging with missing wedge correction in biological electron tomography

被引:127
作者
Bartesaghi, A. [1 ]
Sprechmann, P. [2 ]
Liu, J. [1 ]
Randall, G. [2 ]
Sapiro, G. [3 ]
Subramaniam, S. [1 ]
机构
[1] Natl Inst Hlth, Ctr Canc Res, Bethesda, MD 20892 USA
[2] Univ Republica, Inst Ingn Elect, Montevideo 11800, Uruguay
[3] Univ Minnesota, Minneapolis, MN 55455 USA
基金
美国国家科学基金会;
关键词
cryo-electron tomography; missing wedge effect; volume registration; volume classification; volume averaging;
D O I
10.1016/j.jsb.2008.02.008
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Strategies for the determination of 3D structures of biological macromolecules using electron crystallography and single-particle electron microscopy utilize powerful tools for the averaging of information obtained from 2D projection images of structurally homogeneous specimens. In contrast, electron tomographic approaches have often been used to study the 3D structures of heterogeneous, one-of-a-kind objects such as whole cells where image-averaging strategies are not applicable. Complex entities such as cells and viruses, nevertheless, contain multiple copies of numerous macromolecules that can individually be subjected to 3D averaging. Here we present a complete framework for alignment, classification, and averaging of volumes derived by electron tomography that is computationally efficient and effectively accounts for the missing wedge that is inherent to limited-angle electron tomography. Modeling the missing data as a multiplying mask in reciprocal space we show that the effect of the missing wedge can be accounted for seamlessly in all alignment and classification operations. We solve the alignment problem using the convolution theorem in harmonic analysis, thus eliminating the need for approaches that require exhaustive angular search, and adopt an iterative approach to alignment and classification that does not require the use of external references. We demonstrate that our method can be successfully applied for 3D classification and averaging of phantom volumes as well as experimentally obtained tomograms of GroEL where the outcomes of the analysis can be quantitatively compared against the expected results. (c) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:436 / 450
页数:15
相关论文
共 27 条
  • [1] [Anonymous], 2001, SIAM monographs on mathematical modeling and computation
  • [2] BARTESAGHI A, 2007, 4 IEEE INT S BIOM IM, P244
  • [3] CROWTHER RA, 1972, MOL REPLACEMENT METH, P173
  • [4] Classification of cryo-electron sub-tomograms using constrained correlation
    Foerster, Friedrich
    Pruggnaller, Sabine
    Seybert, Anja
    Frangakis, Achilleas S.
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2008, 161 (03) : 276 - 286
  • [5] Retrovirus envelope protein complex structure in situ studied by cryo-electron tomography
    Förster, F
    Medalia, O
    Zauberman, N
    Baumeister, W
    Fass, D
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (13) : 4729 - 4734
  • [6] Identification of macromolecular complexes in cryoelectron tomograms of phantom cells
    Frangakis, AS
    Böhm, J
    Förster, F
    Nickell, S
    Nicastro, D
    Typke, D
    Hegerl, R
    Baumeister, W
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (22) : 14153 - 14158
  • [7] Frank J., 2006, Three-Dimensional Electron Microscopy of Macromolecular Assemblies: Visualization of Biological Molecules in Their Native State
  • [8] HARAUZ G, 1988, METHOD ENZYMOL, V164, P35
  • [9] KOSTELEC PJ, 2003, FETS ROTATION GROUP
  • [10] Fast rotational matching of rigid bodies by fast Fourier transform acceleration of five degrees of freedom
    Kovacs, JA
    Chacón, P
    Cong, Y
    Metwally, E
    Wriggers, W
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2003, 59 : 1371 - 1376