Experimental investigation on thermal management for small container data center

被引:28
作者
Chu, Wen-Xiao [1 ]
Hsu, Chang-Sheng [1 ]
Tsui, Yeng-Yung [1 ]
Wang, Chi-Chuan [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Mech Engn, 1001 Univ Rd, Hsinchu 300, Taiwan
关键词
Container data center; Cooling performance; Recirculation; Rack cooling index; Supplied heat index; AISLE CONTAINMENT; AIR; PERFORMANCE;
D O I
10.1016/j.jobe.2018.10.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The energy consumptions of data centers are increasing dramatically and cooling systems using for controlling the operating temperature usually consume more than half of these energy. Thus, effective strategies on thermal management in data centers may have benefit on energy savings. In order to improve the power usage effectiveness (PUE) of data centers, the effects of air supply flowrate by computer room air handler (CRAH), intake flowrate of rack cooling fans, air supply grilles and heat load distribution on the cooling performance of a typical small container data center having overhead air supply system are investigated in this paper. The rack cooling index (RCI) and supply heat index (SHI) are incorporated to evaluate the local and average cooling performance of data racks. It is found that the intake flowrate of rack cooling fans plays dominant role, which is suggested to be greater than the air supply flowrate in normal operation. Meanwhile, the volumetric flowrate distribution of grilles is studied. The additional front grille before entering the cold aisle may improve the RCI and SHI of front rack (rack A), in which severe hot-air recirculation may occur in typical operation. Conversely, additional rear grille at the exit of cold aisle has negative effect on cooling performance of the last rack (rack E). Based on the measurement of local temperature distribution, the non-uniform heat load distribution in racks is proposed. Result shows that the RCI can be improved to 64% if more power is placed at lower half part, which is eligible for energy saving. However, the non-uniform heat load distribution shows limited improvement on the rear rack (rack E).
引用
收藏
页码:317 / 327
页数:11
相关论文
共 38 条
  • [1] Experimentally Validated Computational Fluid Dynamics Model for a Data Center With Cold Aisle Containment
    Alkharabsheh, Sami A.
    Sammakia, Bahgat G.
    Shrivastava, Saurabh K.
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2015, 137 (02)
  • [2] Experimental Investigation of Air Flow Through a Perforated Tile in a Raised Floor Data Center
    Arghode, Vaibhav K.
    Joshi, Yogendra
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2015, 137 (01)
  • [3] ASHRAE Technical Committee, 2011, THERM GUID DAT PROC
  • [4] Experimentally Validated Computational Fluid Dynamics Model for Data Center With Active Tiles
    Athavale, Jayati
    Joshi, Yogendra
    Yoda, Minami
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2018, 140 (01)
  • [5] A review of current status of free cooling in datacenters
    Daraghmeh, Hafiz M.
    Wang, Chi-Chuan
    [J]. APPLIED THERMAL ENGINEERING, 2017, 114 : 1224 - 1239
  • [6] A review of data center cooling technology, operating conditions and the corresponding low-grade waste heat recovery opportunities
    Ebrahimi, Khosrow
    Jones, Gerard F.
    Fleischer, Amy S.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 31 : 622 - 638
  • [7] Effect of isolating cold aisles on rack inlet temperature
    Gondipalli, Srujan
    Bhopte, Siddharth
    Sammakia, Bahgat
    Iyengar, Madhusudan K.
    Schmidt, Roger
    [J]. 2008 11TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, VOLS 1-3, 2008, : 1247 - +
  • [8] Herrlin M. K., 2005, RACK COOLING EFFECTI
  • [9] Joshi Y, 2011, J ENHANC HEAT TRANSF, V18, P15, DOI 10.1615/JEnhHeatTransf.v18.i1.20
  • [10] Kumar P., 2012, COLD AISLE AIR DISTR