Improved cascade controller design methodology based on outer-loop decomposition

被引:10
作者
Cakiroglu, Osman [1 ]
Guzelkaya, Mujde [1 ]
Eksin, Ibrahim [1 ]
机构
[1] Istanbul Tech Univ, Fac Elect & Elect Engn, Dept Control & Automat Engn, TR-34469 Istanbul, Turkey
关键词
Cascade controller design; P-PI controller; Smith predictor; time-delay systems; SMITH PREDICTOR; INTEGRATING PROCESSES; CONTROL-SYSTEMS; TIME-DELAY; PERFORMANCE;
D O I
10.1177/0142331214536202
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this study, a new serial cascade controller design methodology is proposed. The inner-loop process is taken as a stable first-order process with time delay and the outer-loop process as an integrating or non-integrating nth-order stable process with time delay. Classical Smith predictors are used to compensate for the time delay in each loop. In the outer loop when the process order is greater than 1, the process model transfer function is decomposed into first-order transfer functions of the required quantity. Next, for each first-order transfer function, a control loop is established and then for each loop an appropriate controller is built up. The controllers are designed to provide a simplified closed-loop transfer function for the existing loop using zero pole cancellation. The decomposed first-order transfer functions results in either an integrator form or a transfer function with one real pole. The resulting controller evolves to be a proportional-type controller for the loops involving the integrator and they appear as a PI-type of controller for the loops involving the real stable pole. To illustrate the effectiveness of the proposed methodology, it is compared with another method given in the literature via simulations.
引用
收藏
页码:623 / 635
页数:13
相关论文
共 19 条
[1]   Robust tuning of Two-Degree-of-Freedom (2-DoF) PI/PID based cascade control systems [J].
Alfaro, V. M. ;
Vilanova, R. ;
Arrieta, O. .
JOURNAL OF PROCESS CONTROL, 2009, 19 (10) :1658-1670
[2]   QUANTITATIVE ANALYSIS OF CASCADE CONTROL [J].
FRANKS, RG ;
WORLEY, CW .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1956, 48 (06) :1074-1079
[3]  
Golnaraghi F., 2017, Automatic Control Systems
[4]   A simple method for tuning cascade control systems [J].
Huang, HP ;
Chien, IL ;
Lee, YC ;
Wang, GB .
CHEMICAL ENGINEERING COMMUNICATIONS, 1998, 165 :89-121
[5]  
Jeng J.-C., 2012, IFAC P, V45, P414
[6]   Simultaneous automatic tuning of cascade control systems from closed-loop step response data [J].
Jeng, Jyh-Cheng ;
Lee, Ming-Wei .
JOURNAL OF PROCESS CONTROL, 2012, 22 (06) :1020-1033
[7]   Improving performance using cascade control and a Smith predictor [J].
Kaya, I .
ISA TRANSACTIONS, 2001, 40 (03) :223-234
[8]  
Kaya I, 2005, 44 IEEE C DEC CONTR
[9]   Use of smith predictor in the outer loop for cascaded control of unstable and integrating processes [J].
Kaya, Ibrahim ;
Atherton, Derek P. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (06) :1981-1987
[10]   Improved cascade control structure for enhanced performance [J].
Kaya, Ibrahim ;
Tan, Nusret ;
Atherton, Derek P. .
JOURNAL OF PROCESS CONTROL, 2007, 17 (01) :3-16