Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs

被引:61
|
作者
Corradini, S. [1 ]
Pilosio, B. [1 ]
Dondi, F. [1 ]
Linari, G. [1 ]
Testa, S. [1 ]
Brugnoli, F. [2 ]
Gianella, P. [3 ]
Pietra, M. [1 ]
Fracassi, F. [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Ozzano Dellemilia, Italy
[2] Portoni Rossi Vet Clin, Bologna, Italy
[3] Univ Turin, Dept Vet Sci, Turin, Italy
来源
JOURNAL OF VETERINARY INTERNAL MEDICINE | 2016年 / 30卷 / 04期
关键词
Canine; Diabetes mellitus; FreeStyle Libre; Noninvasive glucose measurement; BLOOD-GLUCOSE; ANIMALS;
D O I
10.1111/jvim.14355
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundA novel flash glucose monitoring system (FGMS) (FreeStyle Libre, Abbott, UK) was recently developed for humans. It continuously measures the interstitial glucose (IG) concentrations for 14 days. ObjectivesTo assess the clinical and analytical accuracy of the FGMS in diabetic dogs. AnimalsTen client-owned diabetic dogs on insulin treatment. MethodsProspective and observational study. The FGMS was placed on the neck for up to 14 days. During the 1st-2nd, 6-7th, and 13-14th days from application, the IG measurements were compared with the plasma (EDTA) glucose (PG) concentrations analyzed by a reference hexokinase based method. ResultsThe application and the use of the FGMS were apparently painless, easy, and well tolerated by all dogs. Mild erythema at the site of the application was found in 5/10 dogs at the end of the wearing period. A good correlation between IG and PG concentrations (rho = 0.94; P < .001) was found. The FGMS was 93, 99, and 99% accurate at low, normal, and high blood glucose concentrations. Mean standard deviation difference from the reference method was 2.3 +/- 46.8 mg/dL. Conclusion and clinical importanceThe FGMS is easy to use and is accurate for IG glucose measurement in diabetic dogs.
引用
收藏
页码:983 / 988
页数:6
相关论文
共 50 条
  • [41] Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes
    Wen, Xiaofang
    Zeng, Nan
    Zhang, Ningbo
    Ou, Tingting
    Li, Xiaowei
    Li, Xiaoying
    Li, Wangen
    Xu, Kang
    Du, Tao
    DIABETES METABOLIC SYNDROME AND OBESITY, 2022, 15 : 3437 - 3445
  • [42] Accuracy of serum β-hydroxybutyrate measurements for the diagnosis of diabetic ketoacidosis in 116 dogs
    Duarte, R
    Simoes, DMN
    Franchini, ML
    Marquezi, ML
    Ikesaki, JH
    Kogika, MM
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2002, 16 (04) : 411 - 417
  • [43] Continuous glucose monitoring in dogs and cats
    Wiedmeyer, C. E.
    DeClue, A. E.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2008, 22 (01) : 2 - 8
  • [44] Flash glucose monitoring and glycemic control in type 1 diabetes with subcutaneous insulin infusion flash glucose monitoring and glycemic control
    Pinheiro, Sara Lomelino
    Bastos, Margarida
    Barros, Luisa
    Melo, Miguel
    Paiva, Isabel
    ACTA DIABETOLOGICA, 2022, 59 (04) : 509 - 515
  • [45] Performance of the Flash Glucose Monitoring System during exercise in youth with Type 1 diabetes
    Giani, Elisa
    Macedoni, Maddalena
    Barilli, Anna
    Petitti, Agnese
    Mameli, Chiara
    Bosetti, Alessandra
    Cristiano, Andrea
    Radovanovic, Dejan
    Santus, Pierachille
    Zuccotti, Gian Vincenzo
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2018, 146 : 321 - 329
  • [46] Clinical Performance of Flash Glucose Monitoring System in Patients with Liver Cirrhosis and Diabetes Mellitus
    Costa, Dalila
    Lourenco, Joana
    Monteiro, Ana Margarida
    Castro, Beatriz
    Oliveira, Patricia
    Tinoco, Maria Carmo
    Fernandes, Vera
    Marques, Olinda
    Goncalves, Raquel
    Rolanda, Carla
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [47] Flash Glucose Monitoring Improves Glucose Control in People with Type 2 Diabetes Mellitus Receiving Anti-diabetic Drug Medication
    Chen, Maoyuan
    Li, Huiqin
    Shen, Yun
    Liu, Bingli
    Yan, Renna
    Sun, Xiaojuan
    Ye, Lei
    Lee, Kok-Onn
    Ma, Jianhua
    Su, Xiaofei
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2021, 129 (12) : 857 - 863
  • [48] Longitudinal study of the flash glucose monitoring system in type 1 diabetics: An mHealth ally in times of COVID-19
    Cervantes-Torres, Laura
    Romero-Blanco, Cristina
    JOURNAL OF CLINICAL NURSING, 2023, 32 (13-14) : 3840 - 3851
  • [49] Comparative System Accuracy of Blood Glucose Monitoring Systems-Advocacy for a New Accuracy Assessment Metric
    Kenning, Matthes
    Puchert, Anselm
    Salzsieder, Eckhard
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025, 19 (01): : 270 - 271
  • [50] Flash glucose monitoring in type 1 diabetes: A comparison with self-monitoring blood glucose
    Babaya, Naru
    Noso, Shinsuke
    Hiromine, Yoshihisa
    Taketomo, Yasunori
    Niwano, Fumimaru
    Yoshida, Sawa
    Yasutake, Sara
    Kawabata, Yumiko
    Ikegami, Hiroshi
    JOURNAL OF DIABETES INVESTIGATION, 2020, 11 (05) : 1222 - 1229