Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs

被引:61
|
作者
Corradini, S. [1 ]
Pilosio, B. [1 ]
Dondi, F. [1 ]
Linari, G. [1 ]
Testa, S. [1 ]
Brugnoli, F. [2 ]
Gianella, P. [3 ]
Pietra, M. [1 ]
Fracassi, F. [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Ozzano Dellemilia, Italy
[2] Portoni Rossi Vet Clin, Bologna, Italy
[3] Univ Turin, Dept Vet Sci, Turin, Italy
来源
JOURNAL OF VETERINARY INTERNAL MEDICINE | 2016年 / 30卷 / 04期
关键词
Canine; Diabetes mellitus; FreeStyle Libre; Noninvasive glucose measurement; BLOOD-GLUCOSE; ANIMALS;
D O I
10.1111/jvim.14355
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundA novel flash glucose monitoring system (FGMS) (FreeStyle Libre, Abbott, UK) was recently developed for humans. It continuously measures the interstitial glucose (IG) concentrations for 14 days. ObjectivesTo assess the clinical and analytical accuracy of the FGMS in diabetic dogs. AnimalsTen client-owned diabetic dogs on insulin treatment. MethodsProspective and observational study. The FGMS was placed on the neck for up to 14 days. During the 1st-2nd, 6-7th, and 13-14th days from application, the IG measurements were compared with the plasma (EDTA) glucose (PG) concentrations analyzed by a reference hexokinase based method. ResultsThe application and the use of the FGMS were apparently painless, easy, and well tolerated by all dogs. Mild erythema at the site of the application was found in 5/10 dogs at the end of the wearing period. A good correlation between IG and PG concentrations (rho = 0.94; P < .001) was found. The FGMS was 93, 99, and 99% accurate at low, normal, and high blood glucose concentrations. Mean standard deviation difference from the reference method was 2.3 +/- 46.8 mg/dL. Conclusion and clinical importanceThe FGMS is easy to use and is accurate for IG glucose measurement in diabetic dogs.
引用
收藏
页码:983 / 988
页数:6
相关论文
共 50 条
  • [31] Evaluation of the FreeStyle® Libre Flash Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes
    Massa, Guy G.
    Gys, Inge
    Op't Eyndt, Anniek
    Bevilacqua, Esmiralda
    Wijnands, Anne
    Declercq, Peter
    Zeevaert, Renate
    HORMONE RESEARCH IN PAEDIATRICS, 2018, 89 (03): : 189 - 199
  • [32] Monitoring of Diabetes Mellitus Using the Flash Glucose Monitoring System: The Owners' Point of View
    Re, Mariachiara
    Del Baldo, Francesca
    Tardo, Antonio Maria
    Fracassi, Federico
    VETERINARY SCIENCES, 2023, 10 (03)
  • [33] Accuracy, satisfaction and usability of a flash glucose monitoring system among children and adolescents with type 1 diabetes attending a summer camp
    Hansen, Erik A.
    Klee, Philippe
    Dirlewanger, Mirjam
    Bouthors, Therese
    Elowe-Gruau, Eglantine
    Stoppa-Vaucher, Sophie
    Phan-Hug, Franziska
    Antoniou, Maria-Christina
    Pasquier, Jerome
    Dwyer, Andrew A.
    Pitteloud, Nelly
    Hauschild, Michael
    PEDIATRIC DIABETES, 2018, 19 (07) : 1276 - 1284
  • [34] Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients
    Choi, Yoo Jin
    Jeon, Su Min
    Yu, Sehyeon
    Jo, Hye-Sung
    Kim, Dong-Sik
    Yu, Young-Dong
    LANGENBECKS ARCHIVES OF SURGERY, 2025, 410 (01)
  • [35] Accuracy and Safety of the 15-Day CareSens Air Continuous Glucose Monitoring System
    Kim, Kyung-Soo
    Lee, Seung-Hwan
    Yoo, Won Sang
    Park, Cheol-Young
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (04) : 222 - 228
  • [36] Accuracy and precision assessment of a new blood glucose monitoring system
    Ji, Li-Nong
    Guo, Li-Xin
    Liu, Li-Bin
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (01) : 181 - 188
  • [37] Accuracy of Flash Glucose Monitoring in Patients with Diabetes Mellitus on Hemodialysis and Its Relationship with Hydration Status
    Genua, Idoia
    Sanchez-Hernandez, Joan
    Jose Martinez, Maria
    Pujol, Isabel
    Places, Jaume
    Gonzalez, Carmen
    Martinez, Esther
    Manuel Diaz, Juan
    Chico, Ana
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (06): : 1308 - 1312
  • [38] The use of real time continuous glucose monitoring or flash glucose monitoring in the management of diabetes: A consensus view of Italian diabetes experts using the Delphi method
    Bruttomesso, D.
    Laviola, L.
    Avogaro, A.
    Bonora, E.
    Del Prato, S.
    Frontoni, S.
    Orsi, E.
    Rabbone, I
    Sesti, G.
    Purrello, F.
    NUTRITION METABOLISM AND CARDIOVASCULAR DISEASES, 2019, 29 (05) : 421 - 431
  • [39] Contact dermatitis from MiaoMiao (an add-on transmitter to FreeStyle Libre flash glucose monitoring system)
    Gatica-Ortega, Maria-Elena
    Pastor-Nieto, Maria-Antonia
    Torres-Aranda, Rafaela
    Luna-Bastante, Loreto
    Perez-Hortet, Cristina
    CONTACT DERMATITIS, 2021, 85 (01) : 92 - 94
  • [40] Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus
    Knies, Marieke
    Teske, Erik
    Kooistra, Hans
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2022, 24 (08) : E223 - E231