Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs

被引:61
|
作者
Corradini, S. [1 ]
Pilosio, B. [1 ]
Dondi, F. [1 ]
Linari, G. [1 ]
Testa, S. [1 ]
Brugnoli, F. [2 ]
Gianella, P. [3 ]
Pietra, M. [1 ]
Fracassi, F. [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Ozzano Dellemilia, Italy
[2] Portoni Rossi Vet Clin, Bologna, Italy
[3] Univ Turin, Dept Vet Sci, Turin, Italy
来源
JOURNAL OF VETERINARY INTERNAL MEDICINE | 2016年 / 30卷 / 04期
关键词
Canine; Diabetes mellitus; FreeStyle Libre; Noninvasive glucose measurement; BLOOD-GLUCOSE; ANIMALS;
D O I
10.1111/jvim.14355
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundA novel flash glucose monitoring system (FGMS) (FreeStyle Libre, Abbott, UK) was recently developed for humans. It continuously measures the interstitial glucose (IG) concentrations for 14 days. ObjectivesTo assess the clinical and analytical accuracy of the FGMS in diabetic dogs. AnimalsTen client-owned diabetic dogs on insulin treatment. MethodsProspective and observational study. The FGMS was placed on the neck for up to 14 days. During the 1st-2nd, 6-7th, and 13-14th days from application, the IG measurements were compared with the plasma (EDTA) glucose (PG) concentrations analyzed by a reference hexokinase based method. ResultsThe application and the use of the FGMS were apparently painless, easy, and well tolerated by all dogs. Mild erythema at the site of the application was found in 5/10 dogs at the end of the wearing period. A good correlation between IG and PG concentrations (rho = 0.94; P < .001) was found. The FGMS was 93, 99, and 99% accurate at low, normal, and high blood glucose concentrations. Mean standard deviation difference from the reference method was 2.3 +/- 46.8 mg/dL. Conclusion and clinical importanceThe FGMS is easy to use and is accurate for IG glucose measurement in diabetic dogs.
引用
收藏
页码:983 / 988
页数:6
相关论文
共 50 条
  • [21] Assessment of Glycometabolism Impairment and Glucose Variability Using Flash Glucose Monitoring System in Patients With Adrenal Diseases
    Han, Minmin
    Cao, Xiaoming
    Zhao, Changjian
    Yang, Luyang
    Yin, Nan
    Shen, Pengliang
    Zhang, Jin
    Gao, Fei
    Ren, Yi
    Liang, Dong
    Yang, Jing
    Zhang, Yi
    Liu, Yunfeng
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [22] Monitoring of diabetic dogs
    Willems, A.
    Smets, P.
    Van de Maele, I.
    Vandenabeele, S.
    Daminet, S.
    VLAAMS DIERGENEESKUNDIG TIJDSCHRIFT, 2012, 81 (04): : 195 - 204
  • [23] Home monitoring of blood glucose concentrations by owners of diabetic dogs and cats
    Sieber-Ruckstuhl, NS
    Casella, M
    Reusch, CE
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2003, 145 (11): : 537 - 543
  • [24] National Consensus in the Use of the Flash Glucose Monitoring System in Portugal
    Cardoso, Helena
    Carvalho, Davide
    Pape, Estevao
    Carrilho, Francisco
    Raposo, Joao Filipe
    Melo, Miguel
    Carvalho, Ema
    Duarte, Rui
    REVISTA PORTUGUESA DE ENDOCRINOLOGIA DIABETES E METABOLISMO, 2019, 14 (01) : 74 - 81
  • [25] FLASH GLUCOSE MONITORING (FGM)
    Szewczyk, Alicja
    Tobiasz-Kalkun, Natasza
    Stefanowicz-Bielska, Anna
    Kobos, Ewa
    Mtynarczuk, Miroslawa
    Kapusciok, Justyna
    Michalowska, Jolanta
    PIELEGNIARSTWO XXI WIEKU-NURSING IN THE 21 CENTURY, 2020, 19 (03): : 189 - 190
  • [26] Flash Glucose Monitoring Compared to Capillary Glucose Levels in Patients With Diabetic Ketoacidosis: Potential Clinical Applications
    Bichard, Lisa K.
    Rushworth, R. Louise
    Torpy, David J.
    ENDOCRINE PRACTICE, 2021, 27 (08) : 813 - 818
  • [27] Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis
    Matoba, Kenta
    Hayashi, Akinori
    Shimizu, Naoya
    Moriguchi, Ibuki
    Kobayashi, Naoyuki
    Shichiri, Masayoshi
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)
  • [28] The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
    Vokounova-Honsova, Sarka
    Navratil, Tomas
    Kohlikova, Eva
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1659 - 1669
  • [29] Flash Glucose Monitoring in children with Congenital Hyperinsulinism; first report on accuracy and patient experience
    Alsaffar, Hussain
    Turner, Lucy
    Yung, Zoe
    Didi, Mohammed
    Senniappan, Senthil
    INTERNATIONAL JOURNAL OF PEDIATRIC ENDOCRINOLOGY, 2018,
  • [30] Home-based subcutaneous continuous glucose monitoring in 10 diabetic dogs
    Affenzeller, N.
    Thalhammer, J. G.
    Willmann, M.
    VETERINARY RECORD, 2011, 169 (08) : 206 - U94