Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs

被引:61
|
作者
Corradini, S. [1 ]
Pilosio, B. [1 ]
Dondi, F. [1 ]
Linari, G. [1 ]
Testa, S. [1 ]
Brugnoli, F. [2 ]
Gianella, P. [3 ]
Pietra, M. [1 ]
Fracassi, F. [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Ozzano Dellemilia, Italy
[2] Portoni Rossi Vet Clin, Bologna, Italy
[3] Univ Turin, Dept Vet Sci, Turin, Italy
来源
JOURNAL OF VETERINARY INTERNAL MEDICINE | 2016年 / 30卷 / 04期
关键词
Canine; Diabetes mellitus; FreeStyle Libre; Noninvasive glucose measurement; BLOOD-GLUCOSE; ANIMALS;
D O I
10.1111/jvim.14355
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundA novel flash glucose monitoring system (FGMS) (FreeStyle Libre, Abbott, UK) was recently developed for humans. It continuously measures the interstitial glucose (IG) concentrations for 14 days. ObjectivesTo assess the clinical and analytical accuracy of the FGMS in diabetic dogs. AnimalsTen client-owned diabetic dogs on insulin treatment. MethodsProspective and observational study. The FGMS was placed on the neck for up to 14 days. During the 1st-2nd, 6-7th, and 13-14th days from application, the IG measurements were compared with the plasma (EDTA) glucose (PG) concentrations analyzed by a reference hexokinase based method. ResultsThe application and the use of the FGMS were apparently painless, easy, and well tolerated by all dogs. Mild erythema at the site of the application was found in 5/10 dogs at the end of the wearing period. A good correlation between IG and PG concentrations (rho = 0.94; P < .001) was found. The FGMS was 93, 99, and 99% accurate at low, normal, and high blood glucose concentrations. Mean standard deviation difference from the reference method was 2.3 +/- 46.8 mg/dL. Conclusion and clinical importanceThe FGMS is easy to use and is accurate for IG glucose measurement in diabetic dogs.
引用
收藏
页码:983 / 988
页数:6
相关论文
共 50 条
  • [1] Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis
    Malerba, Eleonora
    Cattani, Chiara
    Del Baldo, Francesca
    Carotenuto, Gaia
    Corradini, Sara
    Golinelli, Stefania
    Drudi, Ignazio
    Fracassi, Federico
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (01) : 83 - 91
  • [2] Accuracy of a flash glucose monitoring system in healthy dogs during isoflurane anesthesia
    Pollack, Elizabeth A.
    Cromwell, Lauren N.
    Zhao, Qianqian
    Sage, Adrianna M.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2025, 86 (02)
  • [3] Evaluation of a flash glucose monitoring system in dogs with diabetic ketoacidosis
    Silva, D. D.
    Cecci, G. R. M.
    Biz, G.
    Chiaro, F. N.
    Zanutto, M. S.
    DOMESTIC ANIMAL ENDOCRINOLOGY, 2021, 74
  • [4] Assessment of postprandial hyperglycemia and circadian fluctuation of glucose concentrations in diabetic dogs using a flash glucose monitoring system
    Shea, Emily K.
    Hess, Rebecka S.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (02) : 843 - 852
  • [5] Accuracy of a continuous glucose monitoring system in dogs and cats with diabetic ketoacidosis
    Reineke, Erica L.
    Fletcher, Daniel J.
    King, Lesley G.
    Drobatz, Kenneth J.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2010, 20 (03) : 303 - 312
  • [6] Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus
    Del Baldo, Francesca
    Canton, Claudia
    Testa, Silvia
    Swales, Harry
    Drudi, Ignazio
    Golinelli, Stefania
    Fracassi, Federico
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (06) : 2296 - 2305
  • [7] Validation of a flash glucose monitoring system in outpatient diabetic cats
    Shea, Emily K.
    Hess, Rebecka S.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (04) : 1703 - 1712
  • [8] Hip sensor location for flash interstitial glucose monitoring system provides adequate clinical accuracy in non-diabetic hypoglycemic dogs
    Evans, Jeremy B.
    Lidbury, Jonathan A.
    Jeffery, Nicholas
    Washburn, Shannon E.
    Patterson, Carly A.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2023, 84 (06)
  • [9] Flash glucose monitoring system in gestational diabetes: a study of accuracy and usability
    Lopes, Sara Campos
    Brito, Ana Isabel
    Barbosa, Mariana
    Matos, Ana Catarina
    Pereira, Maria Lopes
    Monteiro, Ana Margarida
    Fernandes, Vera
    HORMONES-INTERNATIONAL JOURNAL OF ENDOCRINOLOGY AND METABOLISM, 2023, 22 (04): : 703 - 713
  • [10] Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations
    Howard, Leigh A.
    Lidbury, Jonathan A.
    Jeffe, Nicholas
    Washburn, Shannon E.
    Patterson, Carly A.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (06) : 2628 - 2635