Interarm Differences in Brachial Blood Pressure and their Effect on the Derivation on Central Aortic Blood Pressure

被引:1
|
作者
Peebles, Karen C. [1 ]
Tan, Isabella [2 ]
Cook, Mitchell T. D. [1 ]
Theobald, Davis A. [1 ]
Avolio, Alberto P. [1 ]
Butlin, Mark [2 ]
机构
[1] Macquarie Univ, Fac Med & Hlth Sci, Dept Hlth Profess, Sydney, NSW, Australia
[2] Macquarie Univ, Fac Med & Hlth Sci, Dept Biomed Sci, Sydney, NSW, Australia
关键词
Interarm blood pressure differences; blood pressure monitoring; cardiovascular disease; aortic blood pressure; ARM DIFFERENCES; PRIMARY-CARE; VASCULAR-DISEASE; HYPERTENSION; PREVALENCE; RECOMMENDATIONS; MORTALITY; AWARENESS; IMPACT;
D O I
10.2991/artres.k.200201.002
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Inter-arm differences in brachial systolic Blood Pressure (BP) are associated with increased cardiovascular risk. It is unclear whether anatomical factors contribute to brachial Interarm Blood Pressure (IABP) differences or whether brachial IABP differences translate to differences in derived central aortic BP. This study aimed to ascertain whether IABP differences in brachial BP correlate with anatomical factors (arm side, dominance, and geometry) and translate to differences in derived central BP. Methods: Brachial BP and derived central BP were measured simultaneously in both arms in 77 community-dwelling adults (18-66 years, 38 male) using two SphygmoCor XCEL (AtCor Medical) BP devices. Measurements were taken 3-4 times in each participant, swapping devices between measurements. An optoelectronic volumeter (Perometer 350S) and hand-held dynamometer (Saehan) were used to measure arm volume and maximal hand-grip strength. Differences in brachial and derived central BP between arms were evaluated by paired t-tests. Regression analysis was used to examine predictors of IABP differences. Results: Absolute IABP difference in brachial systolic BP was 4.2 +/- 3.6 mmHg. Brachial systolic IABP differences were not different between arms (right/left, dominant/non-dominant, or large/small arm volume). Brachial systolic IABP differences were not correlated with differences in arm volume or grip strength. Male sex and diastolic BP were the only predictors. Brachial systolic IABP difference translated to a small (3.1 +/- 2.4 mmHg) difference in derived central BP. Conclusion: As there is only a single aortic BP, we consider the difference in derived central BP likely an artefact. The possibility that it results from BP variability warrants further investigation. (C) 2020 Association for Research into Arterial Structure and Physiology. Publishing services by Atlantis Press International B.V.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [31] The differential impact of aerobic and isometric handgrip exercise on blood pressure variability and central aortic blood pressure
    Seidel, Maximilian
    Pagonas, Nikolaos
    Seibert, Felix S.
    Bauer, Frederic
    Rohn, Benjamin
    Vlatsas, Stergios
    Muehlberger, Dominic
    Nina, Babel
    Westhoff, Timm H.
    JOURNAL OF HYPERTENSION, 2021, 39 (07) : 1269 - 1273
  • [32] Discordant effects of β-blockade on central aortic systolic and brachial systolic blood pressure:: Considerations beyond the cuff
    Epstein, Benjamin J.
    Anderson, Shawn
    PHARMACOTHERAPY, 2007, 27 (09): : 1322 - 1333
  • [33] Central Aortic Systolic Blood Pressure Exhibits Advantages Over Brachial Blood Pressure Measurements in Chronic Kidney Disease Risk Prediction in Women
    Zhang, Linfeng
    Wang, Zengwu
    Chen, Zuo
    Wang, Xin
    Tian, Ye
    Shao, Lan
    Zhu, Manlu
    KIDNEY & BLOOD PRESSURE RESEARCH, 2018, 43 (04) : 1375 - 1387
  • [34] Is 24-Hour Central Blood Pressure Superior to 24-Hour Brachial Blood Pressure for Predicting Organ Damage?
    Schutte, Aletta Elisabeth
    Laurent, Stephane
    HYPERTENSION, 2017, 70 (06) : 1082 - 1083
  • [35] Elevated Interarm Systolic Blood Pressure Difference Is Positively Associated with Increased Likelihood of Coronary Artery Disease
    Li, Min
    Fan, Fangfang
    Zhang, Yan
    Ma, Wei
    Huo, Yong
    INTERNATIONAL JOURNAL OF HYPERTENSION, 2021, 2021
  • [36] Baseline predictors of central aortic blood pressure: A PEAR substudy
    Rosenwasser, Rebecca F.
    Shah, Niren K.
    Smith, Steven M.
    Wen, Xuerong
    Gong, Yan
    Gums, John G.
    Nichols, Wilmer W.
    Chapman, Arlene B.
    Boerwinkle, Eric
    Johnson, Julie
    Epstein, Benjamin
    JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2014, 8 (03) : 152 - 158
  • [37] Central blood pressure reflects left ventricular load, while brachial blood pressure reflects arterial damage
    Yamashita, Sumiyo
    Dohi, Yasuaki
    Takase, Hiroyuki
    Sugiura, Tomonori
    Ohte, Nobuyuki
    BLOOD PRESSURE, 2014, 23 (06) : 356 - 362
  • [38] The ankle brachial index exhibits better association with cardiovascular outcomes than interarm systolic blood pressure difference in patients with type 2 diabetes
    Lin, Liang-Yu
    Hwu, Chii-Min
    Chu, Chia-Huei
    Won, Justin G. S.
    Chen, Harn-Shen
    Chang, Li-Hsin
    MEDICINE, 2019, 98 (19)
  • [39] Determination of central blood pressure by a noninvasive method (brachial BP and QKD interval)
    Cremer, Antoine
    Butlin, Mark
    Codjo, Leopold
    Coulon, Paul
    Ranouil, Xavier
    Joret, Cedric
    Coste, Pierre
    Asmar, Roland
    Avolio, Alberto
    Gosse, Philippe
    JOURNAL OF HYPERTENSION, 2012, 30 (08) : 1533 - 1539
  • [40] Associations between interarm differences in blood pressure and cardiovascular disease outcomes: protocol for an individual patient data meta-analysis and development of a prognostic algorithm
    Clark, Christopher E.
    Boddy, Kate
    Warren, Fiona C.
    Taylor, Rod S.
    Aboyans, Victor
    Cloutier, Lyne
    McManus, Richard J.
    Shore, Angela C.
    Campbell, John L.
    BMJ OPEN, 2017, 7 (06):