The occlusal precision of milled versus printed provisional crowns

被引:21
作者
Giannetti, Luca [1 ]
Apponi, Roberto [1 ]
Mordini, Lorenzo [2 ]
Presti, Sara [1 ]
Breschi, Lorenzo [3 ]
Mintrone, Francesco [1 ]
机构
[1] Univ Modena & Reggio Emilia, Dept Dent & Oral Maxillo Facial Surg, Largo Pozzo 71, I-41124 Modena, MO, Italy
[2] Tufts Univ, Dept Periodontol, Sch Dent Med, Boston, MA 02111 USA
[3] Univ Bologna Alma Mater Studiorum, Dept Biomed & Neuromotor Sci, DIBINEM, Bologna, BO, Italy
关键词
Occlusal precision; 3D printing; CAD; -CAM; Digital dentistry; INTERNAL FIT; CAD/CAM; ACCURACY; FUTURE;
D O I
10.1016/j.jdent.2021.103924
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to compare the occlusal precision of computer-aided-design/ computerassisted-manufacturing (CAD/CAM) milled versus 3D printed polymethylmethacrylate (PMMA) temporary prosthetic crowns , starting from the same digital CAD design. Materials and methods: The study sample included 34 patients presenting 34 premolars in need of prosthetic rehabilitation: a total of 68 temporary crowns were manufactured, 34 of which milled and 34 printed. Immediately after manufacturing, the milled and printed provisionals were scanned with a desktop scanner (E1, 3Shape) to obtain STL files, that were superimposed to the original CAD design in order to identify the occlusal trueness (Analysis A). A second occlusal comparison was performed by scanning both kind of provisional after being placed intraorally with Trios scanner (3 Shape); intraoral scans were obtained in order to compare STL files of provisionals before and after occlusal adjustments (Analysis B). The occlusal trueness was identified at three reference points, P1 (vestibular cusp), P2 (palatal / lingual cusp), P3 (central fossa). The statistical analysis was performed using the R 3.4.3 statistical software (The R Foundation for Statistical Computing), with a significance level of p <0.05. Results: Overall, the printed crowns showed lower occlusal differences than the milled crowns, when compared to the CAD design file, with a statistically significant difference in P1 (difference of 0.025 +/- 0.046 mm), P2 (difference of 0.027 +/- 0 0.044 mm) and P3 ( difference of 0.018 +/- 0.050) for Analysis A (p <0.05). In the Analysis B the direct comparison between the degree of average difference between the pre-adjustment and the post-occlusal adjustment of the milled and printed crowns shows that the printed crowns have lower occlusal mean difference values in all three points compared to the milled ones (difference of 0.146 +/- 0.273 mm in P1, 0.285 +/- 0.360 mm in P2 and 0.257 +/- 0.277 mm in P3). Conclusions: Within the limitation of this study, the data obtained showed a better occlusal surface dimensional accuracy of the 3D printed provisional crowns, when compared to the milled ones. Comparing the results obtained, it is possible to assume that the intraoral scans also had a contribution to occlusion, beside the manufacturing method. 3D printing can be successfully applied for manufacturing temporary PMMA crowns.
引用
收藏
页数:8
相关论文
共 27 条
[1]   Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns [J].
Abdullah, Adil Othman ;
Tsitrou, Effrosyni A. ;
Pollington, Sarah .
JOURNAL OF APPLIED ORAL SCIENCE, 2016, 24 (03) :258-263
[2]   Advancements in CAD/CAM technology: Options for practical implementation [J].
Alghazzawi, Tariq F. .
JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (02) :72-84
[3]   Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs [J].
Alharbi, Nawal ;
Alharbi, Saud ;
Cuijpers, Vincent M. J. I. ;
Osmane, Reham B. ;
Wismeijer, Daniel .
JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (02) :218-226
[4]  
Arora Sheen Juneja, 2016, J Indian Prosthodont Soc, V16, P42, DOI 10.4103/0972-4052.164911
[5]   The evolution of rapid prototyping in dentistry: a review [J].
Azari, Abbas ;
Nikzad, Sakineh .
RAPID PROTOTYPING JOURNAL, 2009, 15 (03) :216-225
[6]   Additive Technology: Update on Current Materials and Applications in Dentistry [J].
Barazanchi, Abdullah ;
Li, Kai Chun ;
Al-Amleh, Basil ;
Lyons, Karl ;
Waddell, J. Neil .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (02) :156-163
[7]   A systematic review of CAD/CAM fit restoration evaluations [J].
Boitelle, P. ;
Mawussi, B. ;
Tapie, L. ;
Fromentin, O. .
JOURNAL OF ORAL REHABILITATION, 2014, 41 (11) :853-874
[8]   A 3-DIMENSIONAL ACCURACY ANALYSIS OF CHAIRSIDE CAD/CAM MILLING PROCESSES [J].
Bosch, Gabriel ;
Ender, Andreas ;
Mehl, Albert .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06) :1425-1431
[9]   Trueness of the Inner Surface of Monolithic Crowns Fabricated by Milling of a Fully Sintered (Y, Nb)-TZP Block in Chairside CAD-CAM System for Single-visit Dentistry [J].
Cho, Jun-Ho ;
Yoon, Hyung-In ;
Han, Jung-Suk ;
Kim, Dae-Joon .
MATERIALS, 2019, 12 (19)
[10]  
Gratton D.G. Aquilino., 2004, Dental Clinics of North America, V48, P487, DOI [10.1016/j.cden.2003.12.007, DOI 10.1016/J.CDEN.2003.12.007]