Effective thermal conductivity of a staggered double layer of vacuum insulation panels

被引:24
作者
Ghazi Wakili, K. [1 ]
Stahl, T. [1 ]
Brunner, S. [1 ]
机构
[1] Empa, Swiss Fed Labs Mat Sci & Technol, CH-8600 Dubendorf, Switzerland
关键词
Vacuum insulation panel; Thermal bridge; Effective thermal conductivity; Edge effect; Linear thermal transmittance; Point thermal transmittance; Evacuated panels; PERFORMANCE; SYSTEM;
D O I
10.1016/j.enbuild.2011.01.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of vacuum insulation panels in buildings has gradually increased in the past few years and developments in their production have occurred in parallel. This has mainly lead to an optimization of different hygro-thermal properties of both the core material as well as the envelope. The issue of thermal bridges caused by the 300 nm thin metallic layers of the barrier envelope and by the joints between two adjacent panels remains. The present study investigates the influence of these thermal bridges on the effective thermal conductivity of a staggered double-layer of vacuum insulation panels. For this purpose a series of guarded hot plate measurements on single- and double-layers of vacuum insulation panels was carried out. The variety of the existing thermal bridge situations was accounted for by different panel size compositions. The results hereof were compared to those of a simplified numerical model. The target is to determine the effective thermal conductivity by a minimum number of required tests and the simplest numerical model. This will enable the determination of additional heat loss induced by the mentioned thermal bridges for a specific envelope laminate type without knowing the details of its composition especially the metallic layers. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1241 / 1246
页数:6
相关论文
共 19 条
[1]   Thermal testing and numerical simulation of a prototype cell using light wallboards coupling vacuum isolation panels and phase change material [J].
Ahmad, M ;
Bontemps, A ;
Sallée, H ;
Quenard, D .
ENERGY AND BUILDINGS, 2006, 38 (06) :673-681
[2]  
[Anonymous], 2007, 10211 EN ISO
[3]   Vacuum insulation panels for building applications: A review and beyond [J].
Baetens, Ruben ;
Jelle, Bjorn Petter ;
Thue, Jan Vincent ;
Tenpierik, Martin J. ;
Grynning, Steinar ;
Uvslokk, Sivert ;
Gustavsen, Arild .
ENERGY AND BUILDINGS, 2010, 42 (02) :147-172
[4]   Investigation of multilayered aluminium-coated polymer laminates by focused ion beam (FIB) etching [J].
Brunner, S ;
Gasser, P ;
Simmler, H ;
Ghazi Wakili, K .
SURFACE & COATINGS TECHNOLOGY, 2006, 200 (20-21) :5908-5914
[5]   In situ performance assessment of vacuum insulation panels in a flat roof construction [J].
Brunner, Samuel ;
Simmler, Hans .
VACUUM, 2008, 82 (07) :700-707
[6]  
Bundi R., 2003, FASSADE, V3, P19
[7]   Vacuum insulation panels - From research to market [J].
Fricke, J. ;
Heinemann, U. ;
Ebert, H. P. .
VACUUM, 2008, 82 (07) :680-690
[8]   Effective thermal conductivity of vacuum insulation panels [J].
Ghazi Wakili, K ;
Bundi, R ;
Binder, B .
BUILDING RESEARCH AND INFORMATION, 2004, 32 (04) :293-299
[9]  
GRYNNING S, J BUILDINGS IN PRESS
[10]   Vacuum maintenance in vacuum insulation panels exemplified with a staggered beam VIP [J].
Kwon, Jae-Sung ;
Jang, Choong Hyo ;
Jung, Haeyong ;
Song, Tae-Ho .
ENERGY AND BUILDINGS, 2010, 42 (05) :590-597