Dynamic contrast-enhanced MRI perfusion of normal muscle in adult hips: Variation of permeability and semi-quantitative parameters

被引:4
作者
El Rafei, Mazen [1 ]
Teixeira, Pedro [2 ]
Norberciak, Laurene [3 ]
Badr, Sammy [1 ,4 ]
Cotten, Anne [1 ,4 ]
Budzik, Jean-Francois [4 ,5 ]
机构
[1] Univ Lille Nord de France, Musculoskeletal Imaging Dept, Lille Reg Univ Hosp, Lille, France
[2] Univ Lorraine, Imaging Dept, Nancy Reg Univ Hosp, Nancy, France
[3] Lille Catholic Univ, Biostat Dept, Lille Catholic Univ Hosp, Lille, France
[4] Univ Lille Nord de France, PMOI Physiopathol Inflammatory Bone Dis, EA 4490, Lille, France
[5] Lille Catholic Univ, Lille Catholic Univ Hosp, Imaging Dept, Lille, France
关键词
DCE-MRI; MRI; Muscle; Hip; Perfusion; ARTERIAL INPUT FUNCTION; MAGNETIC-RESONANCE; SKELETAL-MUSCLE; PROSTATE-CANCER; REPRODUCIBILITY; FEASIBILITY; DIAGNOSIS; FLOW;
D O I
10.1016/j.ejrad.2018.08.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this prospective study was to ascertain the degree of variation of semi-quantitative and permeability parameters on DCE-MRI of normally appearing striated muscles. Dynamic contrast-enhanced MRI of the right hip was performed in 20 women and 24 men. Mean age was 39.1 +/- 12.4 years. Two regions of interest (ROI) were drawn in twelve muscles of anterior, medial and gluteal compartments: a free-form ROI covering the largest muscle section and a smaller elliptical ROI. Semi-quantitative and permeability parameters were calculated using the extended Tofts model. Statistical analysis was performed with a linear mixed model to assess perfusion parameters variation. Intra-and inter-observer agreements were assessed. The intra-observer agreement was considered to be good for free-form ROI (minimum Intra-Class Coefficient (ICC)=0.72) and moderate for elliptical ROI (minimum ICC= 0.51), while the inter-observer agreement was considered to be bad in both cases (minimum ICC = 0.11). There was a high inter-individual variation in most of the perfusion parameters evaluated. The average coefficients of variation were: Time To Peak = 9%, Area Under the Curve = 44%, V-e = 61%, K-ep = 90%, Initial Slope = 99%, and K-trans = 128%. A considerable variation in resting muscle perfusion parameters was seen. This could lead to errors in the analysis of muscle DCE-MRI studies or oncologic/non oncologic studies using muscle as a referential. Further studies targeted on acquisition protocols and post-processing software are necessary to improve the performance of muscle MR perfusion.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 31 条
[1]   Early assessment of breast cancer response to neoadjuvant chemotherapy by semi-quantitative analysis of high-temporal resolution DCE-MRI: Preliminary results [J].
Abramson, Richard G. ;
Li, Xia ;
Hoyt, Tamarya Lea ;
Su, Pei-Fang ;
Arlinghaus, Lori R. ;
Wilson, Kevin J. ;
Abramson, Vandana G. ;
Chakravarthy, A. Bapsi ;
Yankeelov, Thomas E. .
MAGNETIC RESONANCE IMAGING, 2013, 31 (09) :1457-1464
[2]  
[Anonymous], J MAGN RESON IMAGING
[3]   Impact of Arterial Input Function Selection on the Accuracy of Dynamic Contrast-Enhanced MRI Quantitative Analysis for the Diagnosis of Clinically Significant Prostate Cancer [J].
Azahaf, Mustapha ;
Haberley, Marc ;
Betrouni, Nacim ;
Ernst, Olivier ;
Behal, Helene ;
Duhamel, Alain ;
Ouzzane, Adil ;
Puech, Philippe .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (03) :737-749
[4]   Associations between muscle perfusion and symptoms in knee osteoarthritis: a cross sectional study [J].
Bandak, E. ;
Boesen, M. ;
Bliddal, H. ;
Riis, R. G. C. ;
Gudbergsen, H. ;
Henriksen, M. .
OSTEOARTHRITIS AND CARTILAGE, 2015, 23 (10) :1721-1727
[5]   Effectiveness of semi-quantitative multiphase dynamic contrast-enhanced MRI as a predictor of malignancy in complex adnexal masses: radiological and pathological correlation [J].
Bernardin, Livia ;
Dilks, Philip ;
Liyanage, Sidath ;
Miquel, Marc E. ;
Sahdev, Anju ;
Rockall, Andrea .
EUROPEAN RADIOLOGY, 2012, 22 (04) :880-890
[6]  
Braunagel M, 2015, INVEST RADIOL, V50, P57, DOI 10.1097/RLI.0000000000000096
[7]  
Budzik J.-F., 2017, SKELET RADIOL
[8]   Bone marrow perfusion measured with dynamic contrast enhanced magnetic resonance imaging is correlated to body mass index in adults [J].
Budzik, Jean-Francois ;
Lefebvre, Guillaume ;
Behal, Helene ;
Verclytte, Sebastien ;
Hardouin, Pierre ;
Teixeira, Pedro ;
Cotten, Anne .
BONE, 2017, 99 :47-52
[9]   Study of proximal femoral bone perfusion with 3D T1 dynamic contrast-enhanced MRI: a feasibility study [J].
Budzik, Jean-Francois ;
Lefebvre, Guillaume ;
Forzy, Gerard ;
El Rafei, Mazen ;
Chechin, David ;
Cotten, Anne .
EUROPEAN RADIOLOGY, 2014, 24 (12) :3217-3223
[10]   Muscle Microvascular Blood Flow, Oxygenation, pH, and Perfusion Pressure Decrease in Simulated Acute Compartment Syndrome [J].
Challa, Sravya T. ;
Hargens, Alan R. ;
Uzosike, Amarachi ;
Macias, Brandon R. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (17) :1453-1459