Evaluation of the Succeeder SF-8200 Fully Automated Coagulation Analyzer

被引:2
作者
Zengi, Oguzhan [1 ,2 ]
Kucuk, Suat H.
机构
[1] Hlth Sci Univ, Bagcilar Training, Dept Med Biochem, Istanbul, Turkey
[2] Res Hosp, Istanbul, Turkey
关键词
analyzer comparison; Bland-Altman plot; SF-8200; coagulometer; Passing-Bablok regression;
D O I
10.7754/Clin.Lab.2021.210151
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The SF-8200 is a new coagulation analyzer developed by Beijing Succeeder Technology Inc., China. The SF-8200 is able to perform clotting, chromogenic, and immunoturbidimetric tests. System capability is a throughput of up to 360 tests per hour, 60 sample tubes can be loaded at any time, and its reaction cuvette capacity is 1,000. The analyzer also has an optional cap piercing module to reduce manual sampling time. We aimed to perform an analytical performance comparison study between Succeeder SF-8200 and Stago Compact Max3 because fully automated coagulation analyzers have become one of the most essential components of clinical laboratories. Methods: Routine coagulation tests were assessed, which are the most ordered in laboratories such as PT, aPTT, and fibrinogen. Stago Compact Max-3 was accepted as the reference instrument in the comparison study. The assay precisions were assessed using fresh and pooled plasma samples or consumer internal quality controls. Hemolysis, lipemia, and icterus interferences were also verified. Results: The coefficients of variation assessed in the intra and inter-assay precision analyses were below 5% representatively for assessed parameters. The inter-analyser comparison demonstrated good results. Results obtained by the SF-8200 showed high comparability predominantly to used reference analyzers, with correlation coefficients ranging from 0.953 to 0.976. In our routine laboratory setting, SF-8200 reached a sample throughput rate of 360 tests per hour. No considerable influence on tests was found for elevated levels of free hemoglobin, bilirubin, or triglycerides. Conclusions: In conclusion, the SF-8200 was an accurate, precise, and reliable coagulation analyzer in routine testing. According to our study, the results demonstrated excellent technical and analytical performance.
引用
收藏
页码:2316 / 2322
页数:7
相关论文
共 8 条
  • [1] Bilic-Zulle L, 2011, BIOCHEM MEDICA, V21, P49
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Clinical Laboratory Standards Institute, H57 GUID IMPL COAG
  • [4] Critical difference calculations revised: inclusion of variation in standard deviation with analyte concentration
    Jones, Graham Ross Dallas
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 : 517 - 519
  • [5] Influence of hemolysis, icterus and lipemia on coagulation tests as performed on Cobas t511 new analyzer
    Montaruli, Barbara
    Guiotto, Cristina
    Cosseddu, Domenico
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 2020, 31 (01) : 48 - 54
  • [6] Errors in clinical laboratories or errors in laboratory medicine?
    Plebani, Mario
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (06) : 750 - 759
  • [7] Evaluation of the automated coagulation analyzer SYSMEX CA 6000
    Quehenberger, P
    Kapiotis, S
    Handler, S
    Ruzicka, K
    Speiser, W
    [J]. THROMBOSIS RESEARCH, 1999, 96 (01) : 65 - 71
  • [8] Evaluation of the automated coagulation analyzer CS-5100 and its utility in high throughput laboratories
    Ratzinger, Franz
    Schmetterer, Klaus G.
    Haslacher, Helmuth
    Perkmann, Thomas
    Belik, Sabine
    Quehenberger, Peter
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (08) : 1193 - 1202