Intertrochanteric femoral fracture after hip resurfacing managed with a reverse distal femoral locking plate: a case report

被引:3
作者
Baxter, Jonathan A. [1 ]
Krkovic, Matija [1 ]
Prakash, Udai [1 ]
机构
[1] Univ Hosp Coventry & Warwickshire, Dept Trauma & Orthopaed Surg, Coventry, W Midlands, England
关键词
Complications of hip resurfacing; Hip resurfacing; LISS plate; Locking plate; Periprosthetic fracture; PERIPROSTHETIC FRACTURES; INTERNAL-FIXATION; STABILIZATION; ARTHROPLASTY; IMPLANTS; FEMUR; METAL; LISS;
D O I
10.1177/112070001002000425
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metal-on-metal hip resurfacing is a popular procedure for a select group of patients. A variety of surgical approaches are being utilised, each of which may be associated with specific complications. We describe an unusual complication following a Ganz trochanteric osteotomy approach, and the technique used to treat the subsequent periprosthetic fracture.
引用
收藏
页码:562 / 564
页数:3
相关论文
共 14 条
[1]   The blood flow to the femoral head/neck junction during resurfacing arthroplasty - A comparison of two approaches using Laser Doppler flowmetry [J].
Amarasekera, H. W. ;
Costa, M. L. ;
Foguet, P. ;
Krikler, S. J. ;
Prakash, U. ;
Griffin, D. R. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (04) :442-445
[2]   Early results of primary Birmingham hip resurfacings - An independent prospective study of the first 230 hips [J].
Back, DL ;
Dalziel, R ;
Young, D ;
Shimmin, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (03) :324-329
[3]   Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: A report on 12 patients [J].
Chakravarthy, Jagannath ;
Bansal, Rajeev ;
Cooper, Julian .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (06) :725-733
[4]   The use of LISS femoral locking plates and cabling in the treatment of periprosthetic fractures around stable proximal femoral implants in elderly patients [J].
Currall, V. ;
Thomason, K. ;
Eastaugh-Waring, S. ;
Ward, A. J. ;
Chesser, T. J. S. .
HIP INTERNATIONAL, 2008, 18 (03) :207-211
[5]   Principles of internal fixation and selection of implants for periprosthetic femoral fractures [J].
Giannoudis, Peter V. ;
Kanakaris, Nikolaos K. ;
Tsiridis, Eleftherios .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (06) :669-687
[6]   Stabilisation of periprosthetic fractures with angular stable internal fixation:: a report of 13 cases [J].
Kääb, MJ ;
Stöckle, U ;
Schütz, M ;
Stefansky, J ;
Perka, C ;
Haas, NP .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (02) :105-110
[7]   Hip resurfacing using the Trochanteric Flip Osteotomy [J].
Killampalli, Vijay V. ;
Hayes, Andrew ;
Parsons, Nick ;
Costa, Mathew L. ;
Prakash, Udai .
HIP INTERNATIONAL, 2009, 19 (02) :131-135
[8]   Less invasive stabilisation system (LISS) for the treatment of periprosthetic femoral fractures: A 3-year follow-up [J].
Kobbe, Philipp ;
Klemm, Ralf ;
Reilmann, Heinrich ;
Hockertz, Thomas J. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (04) :472-479
[9]   Intracapsular fracture of the proximal femur fracture after hip resurfacing treated by cannulated screws [J].
Kutty, S. ;
Pettit, P. ;
Powell, J. N. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (08) :1100-1102
[10]  
NICE, 2002, 44 NICE