Comparison of planar vs. SPECT images for lesion detectability

被引:0
|
作者
Sorensen, ES
Zeng, GL
Holt, B
Scott, K
Karen, S
Ovard, T
机构
来源
2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3 | 2003年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This research used computer simulation along with human observer studies to evaluate SPECT and planar imaging for lesion detection. The research initially focused on a simple computer simulated phantom consisting of a large sphere with a lesion placed inside at various depths. A constant lesion to background ratio of 8 to 1 was maintained throughout the trials. Two noise levels were simulated by varying the mean value of the sphere and lesion. Both planar and SPECT images were generated simulating a clinical scan time of 30 minutes. Results showed SPECT images consistently had higher contrast but also higher noise values than planar images. When the lesion was located near the center of the sphere the contrast-to-noise ratio was consistently higher in SPECT images. Research using a realistic computer model of the human torso along with realistic image acquisition and reconstruction techniques was then carried out. Planar images were generated with modeling attenuation, scatter and geometric point response. SPECT images were projected and then reconstructed with an OSEM algorithm accounting for attenucation, the scatter and the geometric point response of the collimator.
引用
收藏
页码:1731 / 1735
页数:5
相关论文
共 50 条
  • [1] Comparison of malignant lesion detectability in planar, SPECT, and dedicated SPECT scintimammography using effective multi-dimensional smoothing
    LaRiviere, PJ
    Pan, X
    Penney, BC
    Chen, C
    RADIOLOGY, 1997, 205 : 1433 - 1433
  • [2] SPECT vs planar imaging for preoperative parathyroid lesion localization.
    Tomas, MB
    Torres, MA
    Bhuiya, T
    Afriyie, MO
    Attie, JN
    Palestro, CJ
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1089 - 1089
  • [3] A filtering algorithm based on SPECT lesion detectability potential
    Kim, JH
    Kim, KI
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1706 - 1710
  • [4] CONTRAST-DETAIL LESION DETECTABILITY COMPARISON BETWEEN PARALLEL BEAM AND FAN BEAM SPECT
    KIM, KI
    LIM, CB
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 930 - 930
  • [5] Comparison of conventional planar lung images with 'planar like' reprojected SPECT data.
    Nunez, M. A.
    Hutton, B. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S128 - S128
  • [6] Ideal-observer analysis of lesion detectability in planar, conventional SPECT, and dedicated SPECT scintimammography using effective multi-dimensional smoothing
    La Riviere, PJ
    Pan, X
    Penney, BC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1273 - 1279
  • [7] Pseudoplanar images obtained from pulmonary SPECT: Agreement of reading and comparison to planar images
    Clappuccini, R.
    Boichot, C.
    Cochet, A.
    Touzery, C.
    Dygai-Cochet, I.
    Berriolo-Riedinger, A.
    Toubeau, M.
    Brunotte, F.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2009, 33 (04): : 169 - 180
  • [8] Scintigraphy of spinal disorders: Comparison of bone SPECT with planar images.
    Orellana, P
    Olea, E
    Quintana, JC
    Fuentes, C
    Astudillo, S
    TOMOGRAPHY IN NUCLEAR MEDICINE, 1996, : 215 - 219
  • [9] Observer studies of cardiac lesion detectability with triple-head 360° vs. dual-head 180° SPECT acquisition using simulated projection data
    Chen, M
    Peter, J
    Jaszczak, RJ
    Gilland, DR
    Bowsher, JE
    Tornai, MP
    Metzler, SD
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2229 - 2233
  • [10] Multi-Camera Comparison of HMPAO SPECT Simulated Lesion Detectability Using a Subresolution Sandwich Phantom
    Holmes, R. B.
    Martin, D.
    Tossici-Bolt, L.
    Jenkins, L.
    Bush, N.
    Kemp, P. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S176 - S176