Porcine liver: Morphologic characteristics and cell viability at experimental radiofrequency ablation with internally cooled electrodes

被引:50
|
作者
Ng, KK
Lam, CM
Poon, RT
Shek, TW
Yu, WC
To, JY
Wo, YH
Lau, CP
Tang, TC
Ho, DW
Fan, ST
机构
[1] Univ Hong Kong, Queen Mary Hosp, Dept Surg, Hong Kong, Hong Kong, Peoples R China
[2] Univ Hong Kong, Queen Mary Hosp, Dept Pathol, Hong Kong, Hong Kong, Peoples R China
[3] Univ Hong Kong, Queen Mary Hosp, Ctr Study Liver Dis, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1148/radiol.2352040425
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate morphologic characteristics and cell viability of radiofrequency ablation zones in porcine liver. MATERIALS AND METHODS: Approval of the study protocol was obtained from the Ethics Committee on Use of Live Animals for Teaching and Research at University of Hong Kong. Internally cooled electrodes were used to produce 120 ablated zones ex vivo and 60 ablated zones in vivo with single electrodes (1-, 2-, and 3-cm exposed lengths) or clustered electrodes (1.0-, 2.0-, and 2.5-cm exposed lengths) at 4, 8, 12, and 16 minutes of ablation (ex vivo) and 8 and 12 minuted of ablation (in vivo). Morphologic measurements of each ablated zone were preformed. Cell viability in each ablated zone was assessed qualitatively with histochemical staining and quantitatively with measurement of intracellular adenosine 5'-triphosphate (ATP) concentration. RESULTS: Exposed length of electrode (coefficient = 0.79, standard error = 0.04, P < .001), duration of ablation (coefficient = 0.14, standard error = 0.01, P < .001), and clustered electrode design (coefficient = 1.21, standard error = 0.005, P < .001) were independent factors that affected minimal transverse diameter and volume of ablated zone in ex vivo study. Similar morphologic characteristics existed among ablated in in vivo study. Mean distance of ablation beyond the electrode tip remained constant (ex vivo, 1.0 cm +/- 0.08 [standard deviation]; in vivo, 0.5 cm +/- 0.05) regardless of different ablation conditions. Histochemical staining revealed no viable hepatocytes from center to margins of white zone (9.5 x 10(-12) mol/mu g DNA +/- 1.43) was lower than that in red zone (4088 x 10(-12) mol/mu g DNA +/- 65.97, P < .001) and in adjacent normal liver (4528 x 10(-12) mol/mu g DNA +/- 52.74, P < .001). CONCLUSION: Distance of ablation beyond the tip of the electrode remained constant (ex vivo, 1.0 cm; in vivo, 0.5 cm) with different conditions of ablation. complete and uniform cellular destruction was achieved in the white zone of ablated area. (C) RSNA, 2005.
引用
收藏
页码:478 / 486
页数:9
相关论文
共 50 条
  • [31] An ex-vivo experimental study on optimization of bipolar radiofrequency liver ablation using perfusion-cooled electrodes
    Lee, JM
    Han, JK
    Kim, SH
    Lee, JY
    Shin, KS
    Choi, BI
    ACTA RADIOLOGICA, 2005, 46 (05) : 443 - 451
  • [32] Radiofrequency ablation using a new type of internally cooled electrode with an adjustable active tip: An experimental study in ex vivo bovine and in vivo porcine livers
    Cha, Jihoon
    Kim, Young-sun
    Rhim, Hyunchul
    Lim, Hyo K.
    Choi, Dongil
    Lee, Min Woo
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (03) : 516 - 521
  • [33] Increasing radiofrequency ablation volumes with the use of internally cooled electrodes and injected hydrochloric acid in ex vivo bovine livers
    Jiang, Xiong-Ying
    Zhang, Tian-Qi
    Li, Guo
    Gu, Yang-Kui
    Gao, Fei
    Yao, Wang
    Zhang, Yan-yang
    Huang, Jin-hua
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 37 - 43
  • [34] Computational modelling of internally cooled wet (ICW) electrodes for radiofrequency ablation: impact of rehydration, thermal convection and electrical conductivity
    Trujillo, Macarena
    Bon, Jose
    Berjano, Enrique
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2017, 33 (06) : 624 - 634
  • [35] Comparison of microwave ablation and multipolar radiofrequency ablation, both using a pair of internally cooled interstitial applicators: Results in ex vivo porcine livers
    Li, Xin
    Zhang, Liang
    Fan, Weijun
    Zhao, Ming
    Wang, Ligang
    Tang, Tian
    Jiang, Hua
    Zhang, Jianlei
    Liu, Yanfeng
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2011, 27 (03) : 240 - 248
  • [36] Radiofrequency Ablation by a 21-Gauge Internally Cooled Electrode: Ex Vivo and In Vivo Evaluation by Rat Liver
    Haruyuki Takaki
    Yuki Kodama
    Hisao Miyamoto
    Yuto Iijima
    Yoshinari Kikuchi
    Hiroshi Kodama
    Eisuke Ueshima
    Keiji Nakasho
    Reona Wada
    Koichiro Yamakado
    CardioVascular and Interventional Radiology, 2021, 44 : 150 - 155
  • [37] Radiofrequency Ablation by a 21-Gauge Internally Cooled Electrode: Ex Vivo and In Vivo Evaluation by Rat Liver
    Takaki, Haruyuki
    Kodama, Yuki
    Miyamoto, Hisao
    Iijima, Yuto
    Kikuchi, Yoshinari
    Kodama, Hiroshi
    Ueshima, Eisuke
    Nakasho, Keiji
    Wada, Reona
    Yamakado, Koichiro
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (01) : 150 - 155
  • [38] Comparison of Microwave Ablation and Multipolar Radiofrequency Ablation In Vivo Using Two Internally Cooled Probes
    Fan, WeiJun
    Li, Xin
    Zhang, Liang
    Jiang, Hua
    Zhang, JianLei
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : W46 - W50
  • [39] Radiofrequency Ablation with an Internally Cooled Electrode for Twin Reversed Arterial Perfusion Sequence
    Wagata, Maiko
    Murakoshi, Takeshi
    Ishii, Keisuke
    Muromoto, Jin
    Sasahara, Jun
    Murotsuki, Jun
    FETAL DIAGNOSIS AND THERAPY, 2016, 40 (02) : 110 - 115
  • [40] Internally cooled bipolar radiofrequency ablation:: Is a lower power output more effective?
    Clasen, S.
    Geng, A.
    Herberts, T.
    Boss, A.
    Schmidt, D.
    Schraml, C.
    Fritz, J.
    Kroeber, S. M.
    Claussen, C. D.
    Pereira, P. L.