In vivo x-ray phase contrast analyzer-based imaging for longitudinal osteoarthritis studies in guinea pigs

被引:38
作者
Coan, Paola [1 ,2 ,3 ,4 ]
Wagner, Andreas [5 ]
Bravin, Alberto [3 ,4 ]
Diemoz, Paul C. [3 ,4 ]
Keyrilainen, Jani [3 ,6 ]
Mollenhauer, Juergen [5 ,7 ,8 ]
机构
[1] Univ Munich, Fac Med, Munich, Germany
[2] Univ Munich, Inst Clin Radiol, Munich, Germany
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[4] Munich Ctr Adv Photon MAP, Munich, Germany
[5] Univ Jena, Dept Orthopaed, Rudolf Elle Hosp Eisenberg, D-6900 Jena, Germany
[6] Univ Helsinki, Cent Hosp, HUCH Canc Ctr, Dept Phys, Helsinki, Finland
[7] Univ Tubingen, NMI, Reutlingen, Germany
[8] TETEC AG, Reutlingen, Germany
关键词
ARTICULAR-CARTILAGE; COMPUTED-TOMOGRAPHY; SYNCHROTRON-RADIATION; REFRACTION; MAMMOGRAPHY; CT; ABSORPTION; KNEE; DEI; RADIOGRAPHY;
D O I
10.1088/0031-9155/55/24/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the last two decades phase contrast x-ray imaging techniques have been extensively studied for applications in the biomedical field. Published results demonstrate the high capability of these imaging modalities of improving the image contrast of biological samples with respect to standard absorption-based radiography and routinely used clinical imaging techniques. A clear depiction of the anatomic structures and a more accurate disease diagnosis may be provided by using radiation doses comparable to or lower than those used in current clinical methods. In the literature many works show images of phantoms and excised biological samples proving the high sensitivity of the phase contrast imaging methods for in vitro investigations. In this scenario, the applications of the so-called analyzer-based x-ray imaging (ABI) phase contrast technique are particularly noteworthy. The objective of this work is to demonstrate the feasibility of in vivo x-ray ABI phase contrast imaging for biomedical applications and in particular with respect to joint anatomic depiction and osteoarthritis detection. ABI in planar and tomographic modes was performed in vivo on articular joints of guinea pigs in order to investigate the animals with respect to osteoarthritis by using highly monochromatic x-rays of 52 keV and a low noise detector with a pixel size of 47 x 47 mu m(2). Images give strong evidence of the ability of ABI in depicting both anatomic structures in complex systems as living organisms and all known signs of osteoarthritis with high contrast, high spatial resolution and with an acceptable radiation dose. This paper presents the first proof of principle study of in vivo application of ABI. The technical challenges encountered when imaging an animal in vivo are discussed. This experimental study is an important step toward the study of clinical applications of phase contrast x-ray imaging techniques.
引用
收藏
页码:7649 / 7662
页数:14
相关论文
共 50 条
  • [21] X-ray phase imaging with a paper analyzer
    Morgan, Kaye S.
    Paganin, David M.
    Siu, Karen K. W.
    APPLIED PHYSICS LETTERS, 2012, 100 (12)
  • [22] Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging
    Willner, M.
    Herzen, J.
    Grandl, S.
    Auweter, S.
    Mayr, D.
    Hipp, A.
    Chabior, M.
    Sarapata, A.
    Achterhold, K.
    Zanette, I.
    Weitkamp, T.
    Sztrokay, A.
    Hellerhoff, K.
    Reiser, M.
    Pfeiffer, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (07) : 1557 - 1571
  • [23] A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging
    Bennett, Eric E.
    Kopace, Rael
    Stein, Ashley F.
    Wen, Han
    MEDICAL PHYSICS, 2010, 37 (11) : 6047 - 6054
  • [24] Grating-based X-ray phase contrast for biomedical imaging applications
    Pfeiffer, Franz
    Herzen, Julia
    Wiliner, Marian
    Chabior, Michael
    Auweter, Sigrid
    Reiser, Maximilian
    Bamberg, Fabian
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (03): : 176 - 185
  • [25] X-Ray Phase-Contrast Technology in Breast Imaging: Principles, Options, and Clinical Application
    Taba, Seyedamir Tavakoli
    Gureyev, Timur E.
    Alakhras, Maram
    Lewis, Sarah
    Lockie, Darren
    Brennan, Patrick C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (01) : 133 - 145
  • [26] Phase-contrast X-ray imaging based on interferometry
    Momose, A
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 136 - 142
  • [27] A sensitive x-ray phase contrast technique for rapid imaging using a single phase grid analyzer
    Morgan, Kaye S.
    Modregger, Peter
    Irvine, Sarah C.
    Rutishauser, Simon
    Guzenko, Vitaliy A.
    Stampanoni, Marco
    David, Christian
    OPTICS LETTERS, 2013, 38 (22) : 4605 - 4608
  • [28] In vivo physiological saline-infused hepatic vessel imaging using a two-crystal-interferometer-based phase-contrast X-ray technique
    Takeda, Tohoru
    Yoneyama, Akio
    Wu, Jin
    Thet-Thet-Lwin
    Momose, Atsushi
    Hyodo, Kazuyuki
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 252 - 256
  • [29] X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials
    Vedantham, Srinivasan
    Karellas, Andrew
    MEDICAL PHYSICS, 2013, 40 (04)
  • [30] Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography
    Brun, E.
    Grandl, S.
    Sztrokay-Gaul, A.
    Barbone, G.
    Mittone, A.
    Gasilov, S.
    Bravin, A.
    Coan, P.
    MEDICAL PHYSICS, 2014, 41 (11)