Synthetic Mesh Augmentation of Acute and Subacute Quadriceps Tendon Repair

被引:19
作者
Morrey, Matthew C. [1 ]
Barlow, Jonathan D. [2 ]
Abdel, Matthew P. [3 ]
Hanssen, Arlen D. [3 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[2] Ohio State Univ, Hand & Upper Extrem Ctr, Columbus, OH 43210 USA
[3] Mayo Clin, Dept Orthoped Surg, 200 First St SW, Rochester, MN 55905 USA
关键词
SUTURE ANCHORS; DELAYED REPAIR; RUPTURES; RECONSTRUCTION;
D O I
10.3928/01477447-20151218-02
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Quadriceps tendon rupture is an uncommon injury. To date, surgical results have been less than favorable. A novel repair technique that uses Marlex mesh (C R Bard, Murray Hill, New Jersey) has been developed. Use of this repair may allow earlier range of motion and functional restoration of extension. The authors sought to evaluate the technical feasibility, durability, and postoperative function of this repair. This study retrospectively analyzed 8 knees (7 patients) operated on with this technique from 1990 to 2011. Mean follow-up was 9 years. Average age at the time of injury was 69 years. Mean operative time was 130 minutes. No perioperative complications occurred, no patients had clinical evidence of failure, and no patients required subsequent reoperation. Mean flexion at final follow-up was 100 degrees. Of the 8 knees, 7 knees had no extensor lag at final follow-up. Marlex mesh augmentation for quadriceps tendon ruptures has promising clinical results, despite significant comorbidities. The results showed that the technique was feasible, with low cost and reasonable operative time. The clinical results were durable, with no intraoperative complications, no re-ruptures, rare extension lag, and good range of motion. Therefore, synthetic mesh augmentation is a feasible option in acute quadriceps tendon ruptures.
引用
收藏
页码:E9 / E13
页数:5
相关论文
共 15 条
[1]  
Browne JA, 2011, J BONE JOINT SURG AM, V93A, P1137, DOI [10.2106/JBJSJ.01036, 10.2106/JBJS.J.01036]
[2]   The Use of Suture Anchors to Repair the Ruptured Quadriceps Tendon [J].
Bushnell, Brandon D. ;
Whitener, George B. ;
Rubright, James H. ;
Creighton, R. Alexander ;
Logel, Kevin J. ;
Wood, Mark L. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (06) :407-413
[3]   Rupture of the quadriceps tendon - An association with a patellar spur [J].
Hardy, JRW ;
Chimutengwende-Gordon, M ;
Bakar, I .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (10) :1361-1363
[4]  
Katzman BM, 1997, ORTHOPEDICS, V20, P553
[5]   Delayed repair of the quadriceps using the Mitek anchor system: A case report and review of the literature [J].
Kerin, C ;
Hopgood, R ;
Banks, AJ .
KNEE, 2006, 13 (02) :161-163
[6]   Outcomes following repair of quadriceps tendon ruptures [J].
Konrath, GA ;
Chen, D ;
Lock, T ;
Goitz, HT ;
Watson, JT ;
Moed, BR ;
D'Ambrosio, G .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (04) :273-279
[7]   Outcomes following quadriceps tendon ruptures [J].
O'Shea, K ;
Kenny, P ;
Donovan, J ;
Condon, F ;
McElwain, JP .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (03) :257-260
[8]   Delayed reconstruction of a quadriceps tendon [J].
Pocock, C. A. J. ;
Trikha, S. P. ;
Bell, J. S. P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (01) :221-224
[9]  
RASUL AT, 1993, CLIN ORTHOP RELAT R, P205
[10]   Repair of quadriceps tendon ruptures using suture anchors [J].
Richards, DP ;