Single-shot MR imaging using trapezoidal-gradient-based Lissajous trajectories

被引:12
作者
Feng, HH [1 ]
Gu, H [1 ]
Silbersweig, D [1 ]
Stern, E [1 ]
Yang, YH [1 ]
机构
[1] Cornell Univ, Weill Med Coll, Funct Neuroimaging Lab, Dept Psychiat, New York, NY 10021 USA
关键词
fast magnetic resonance imaging (MRI); image artifacts; image reconstruction; Lissajous trajectory;
D O I
10.1109/TMI.2003.815902
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A novel single-shot trapezoidal-gradient-based Lissajous trajectory is described and implemented on a 3-tesla magnetic resonance (MR) scanner. A feature of this trajectory is that its sampling points are located on a nonequidistant rectangular grid, which permits the usage of one-dimensional optimal algorithms to increase the robustness and speed of image reconstruction. Another advantage of the trajectory is that two images with different effective echo times can be obtained within a single excitation, which might be used for fast T-2* mapping, in functional MR imaging scanning of brain activity associated with mental processes. Potential artifacts in reconstructed images were investigated and methods for suppressing these artifacts were developed. Experiments on normal subjects at rest and during brain activation were performed to demonstrate the feasibility of the new sequence.
引用
收藏
页码:925 / 932
页数:8
相关论文
共 20 条
  • [1] HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1.
    AHN, CB
    KIM, JH
    CHO, ZH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) : 2 - 7
  • [2] PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN
    BANDETTINI, PA
    JESMANOWICZ, A
    WONG, EC
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 161 - 173
  • [3] RECONSTRUCTION FROM NMR DATA ACQUIRED WITH IMAGING GRADIENTS HAVING ARBITRARY TIME-DEPENDENCE
    CHEN, DQ
    MARR, RB
    LAUTERBUR, PC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (03) : 162 - 164
  • [4] DEWALLE RV, 2000, IEEE T MED IMAGING, V19, P1160
  • [5] CORRECTING FOR NONUNIFORM K-SPACE SAMPLING IN 2-DIMENSIONAL NMR SELECTIVE EXCITATION
    HARDY, CJ
    CLINE, HE
    BOTTOMLEY, PA
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (03): : 639 - 645
  • [6] Hou L, 1999, JMRI-J MAGN RESON IM, V9, P233, DOI 10.1002/(SICI)1522-2586(199902)9:2<233::AID-JMRI13>3.0.CO
  • [7] 2-V
  • [8] SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING
    JACKSON, JI
    MEYER, CH
    NISHIMURA, DG
    MACOVSKI, A
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 473 - 478
  • [9] Likes Richard S, 1981, US Patent, Patent No. [4 307 343, 4307343, 4,307,343]
  • [10] MANSFIELD P, 1975, J MAGN RESON, V18, P69