Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyes

被引:381
作者
Hoffmann, Peter Christian [1 ]
Huetz, Werner W. [2 ]
机构
[1] Augenklin, Private Eye Surg Ctr, Castrop Rauxel, Germany
[2] Klinikum Bad Hersfeld, Augenklin, Bad Hersfeld, Germany
关键词
ANTERIOR-CHAMBER DEPTH; PARTIAL COHERENCE INTERFEROMETRY; INTRAOCULAR-LENS CALCULATION; IMPLANT POWER CALCULATION; CATARACT-SURGERY; AXIAL LENGTH; ULTRASOUND BIOMETRY; CALCULATION FORMULA; ZEISS IOLMASTER; IOL CALCULATION;
D O I
10.1016/j.jcrs.2010.02.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To present and analyze biometry data sets and prevalence data for corneal astigmatism in a large population SETTING: High-volume eye surgery center, Castrop-Rauxel, Germany. METHODS: Axial length (AL). corneal radii, anterior chamber depth (ACD), and horizontal corneal diameter (white-to-white [WTW] distance) were optically measured by partial coherence interferometry (IOLMaster). Patient data sets acquired between 2000 and 2006 were reviewed and analyzed RESULTS: The study evaluated 23 239 data sets of 15 448 patients with a median age of 74 years The mean values were as follows AL, 23 43 mm +/- 1.51 (SD); corneal radius, 7 69 +/- 0 28 mm; WTW distance, 11 82 +/- 0.40 mm, and ACD, 3.11 +/- 043 mm The ACD and axis of astigmatism were correlated with age. The AL, corneal radius, ACD, and WTW were correlated with one other Eight percent of eyes had corneal astigmatism greater than 2 00 diopters (D), and 2 6% had more than 3.00 D Astigmatism was with the rule (WTW) in 46 8% of eyes, against the rule in 34 4%, and oblique in 18 9%. High astigmatism was predominantly WTW. CONCLUSIONS: The results in this analysis might provide normative data for cataract patients and a useful reference for multiple purposes The correlation of AL with corneal radius, ACD, and corneal diameter in normal eyes was not present in eyes with extreme myopia or hyperopia. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. J Cataract Refract Surg 2010; 36.1479-1485 (C) 2010 ASCRS and ESCRS
引用
收藏
页码:1479 / 1485
页数:7
相关论文
共 33 条
[1]  
ANSTICE J, 1971, AMER J OPT ARCH AM A, V48, P1001
[2]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[3]   IOLMaster biometry: refractive results of 100 consecutive cases [J].
Eleftheriadis, H .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (08) :960-963
[4]   Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic [J].
Ferrer-Blasco, Teresa ;
Gonzalez-Meijome, Jose Manuel ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :424-432
[5]   Prevalence of corneal astigmatism before cataract surgery [J].
Ferrer-Blasco, Teresa ;
Montes-Mico, Robert ;
Peixoto-de-Matos, Sofia C. ;
Gonzalez-Meijome, Jose M. ;
Cervino, Alejandro .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :70-75
[6]   Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery [J].
Findl, O ;
Kriechbaum, K ;
Sacu, S ;
Kiss, B ;
Polak, K ;
Nepp, J ;
Schild, G ;
Rainer, G ;
Maca, S ;
Petternel, V ;
Lackner, B ;
Drexler, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (10) :1950-1955
[7]   REFRACTION DURING THE 1ST YEAR OF LIFE AND DEVELOPMENT OF ASTIGMATISM [J].
FRIEDBURG, D ;
SONS, S .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1983, 182 (04) :309-311
[8]   With the rule astigmatism is not the rule in the elderly -: Reykjavik Eye Study:: A population based study of refraction and visual acuity in citizens of Reykjavik 50 years and older [J].
Gudmundsdottir, E ;
Jonasson, F ;
Jonsson, V ;
Stefánsson, E ;
Sasaki, H ;
Sasaki, K .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (06) :642-646
[9]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[10]  
HAIGIS W, EUROPEAN USER GROUP